alNESpecificAMPNbr OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This variable contains the NE type specific value unique within
the context of the NE type, and used to identify which alarm manual
page shall be shown to the user. Alarm manual page is additional
information to be provided to the user to give guidance what are
the possible reasons of the alarm, how the user can recover from
the problem etc.
This information is like one or more pages in the NE products
reference manual describing the possible alarm reported by the NE
and reasons of the alarms. Each NE product is responsible for
keeping these values unique within the context of their product
and provide the contents of user manual pages. When supporting
this variable, only positive values are allowed. When this variable
has value 0, it means that no alarm manual page is associated to
the alarm or this field is not supported by the NE."
View at oid-info.com
This variable contains the NE type specific value unique within the
context of the NE type, and used to identify which alarm manual page
shall be shown to the user. Alarm manual page is additional information
to be provided to the user to give guidance what are the possible
reasons of the alarm, how the user can recover from the problem etc.
This information is like one or more pages in the NE products reference
manual describing the possible alarm reported by the NE and reasons of
the alarms. Each NE product is responsible for keeping these values
unique within the context of their product and provide the contents
of user manual pages. When supporting this variable, only positive
values are allowed. When this variable has value 0, it means that no
alarm manual page is associated to the alarm or this field is not
supported by the NE.
Parsed from file NOKIA-COMMON-ALARM-REPORTING-MIB.my.txt
Company: None
Module: NOKIA-COMMON-ALARM-REPORTING-MIB
This variable contains the NE type specific value unique within the
context of the NE type, and used to identify which alarm manual page
shall be shown to the user. Alarm manual page is additional information
to be provided to the user to give guidance what are the possible
reasons of the alarm, how the user can recover from the problem etc.
This information is like one or more pages in the NE products reference
manual describing the possible alarm reported by the NE and reasons of
the alarms. Each NE product is responsible for keeping these values
unique within the context of their product and provide the contents
of user manual pages. When supporting this variable, only positive
values are allowed. When this variable has value 0, it means that no
alarm manual page is associated to the alarm or this field is not
supported by the NE.
Parsed from file NOKIA-COMMON-ALARM-REPORTING-MIB.mib
Module: NOKIA-COMMON-ALARM-REPORTING-MIB
Automatically extracted from a module checked by a user of the Asnp syntax-checking tool
alNESpecificAMPNbr OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This variable contains the NE type specific value unique within the context of the NE type, and used to identify which alarm manual page shall be shown to the user. Alarm manual page is additional information to be provided to the user to give guidance what are the possible reasons of the alarm, how the user can recover from the problem etc. This information is like one or more pages in the NE products reference manual describing the possible alarm reported by the NE and reasons of the alarms. Each NE product is responsible for keeping these values unique within the context of their product and provide the contents of user manual pages. When supporting this variable, only positive values are allowed. When this variable has value 0, it means that no alarm manual page is associated to the alarm or this field is not supported by the NE." ::= {alAlarmLogEntry 9}
alNESpecificAMPNbr OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This variable contains the NE type specific value unique within the context of the NE type, and used to identify which alarm manual page shall be shown to the user. Alarm manual page is additional information to be provided to the user to give guidance what are the possible reasons of the alarm, how the user can recover from the problem etc. This information is like one or more pages in the NE products reference manual describing the possible alarm reported by the NE and reasons of the alarms. Each NE product is responsible for keeping these values unique within the context of their product and provide the contents of user manual pages. When supporting this variable, only positive values are allowed. When this variable has value 0, it means that no alarm manual page is associated to the alarm or this field is not supported by the NE." ::= {alAlarmLogEntry 9}
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.94.1.16.1.3.2.1.1.1 | alTrapIndex | 0 | 0 | Used as an index of the table. The value of this variable equals to variable caTrapId in the corresponding alarm trap. |
1.3.6.1.4.1.94.1.16.1.3.2.1.1.2 | alSpecificTrap | 0 | 0 | The value equals to the value of the specific-trap field in the corresponding Nokia enterprise specific alarm trap. |
1.3.6.1.4.1.94.1.16.1.3.2.1.1.3 | alTimeStamp | 0 | 0 | The value equals to the time stamp as reported in the corresponding Nokia enterprise specific trap. The value of this field shal… |
1.3.6.1.4.1.94.1.16.1.3.2.1.1.4 | alAlarmText | 0 | 0 | This variable contains alarm information in human readable format to be shown e.g. in NMS UI. No processing of the contents of t… |
1.3.6.1.4.1.94.1.16.1.3.2.1.1.5 | alCorrelatedAlarmId | 0 | 0 | The value of this variable equals to the value of corresponding field in alarm and alarm clearing trap (caCorrelatedAlarmId). Wh… |
1.3.6.1.4.1.94.1.16.1.3.2.1.1.6 | alFirstColumnInTbl | 0 | 0 | This variable is used to reference to an conceptual row which represents the failed resource (see caColumnInTbl for further deta… |
1.3.6.1.4.1.94.1.16.1.3.2.1.1.7 | alRowIdx | 0 | 0 | This variable contains value {0 0} for the time being. |
1.3.6.1.4.1.94.1.16.1.3.2.1.1.8 | alSeverity | 0 | 0 | This variable contains the severity of the detected failure as reported by the NE. |
1.3.6.1.4.1.94.1.16.1.3.2.1.1.10 | alSupplementaryInfo | 0 | 0 | Supplementary information fields of the last Nokia enterprise specific alarm trap emitted by the NE. Alarm manual page contains t… |