The serial port which the UPS software use to communicate
with the UPS. The format varies from platform to platform.
For DOS program, the format is 'portNo, portAddress, portIRQ'
(e.g. '1, 0x2f8, 3' for COM2). For Windows program, it
is 'portNo'. For NetWare program, it is
'portType, boardNo, portNo'. For UNIX, it is 'device name'.
Parsed from file syups.mib.txt
Company: None
Module: SYNSO-UPSMIB
The serial port which the UPS software use to communicate
with the UPS. The format varies from platform to platform.
For DOS program, the format is 'portNo, portAddress, portIRQ'
(e.g. '1, 0x2f8, 3' for COM2). For Windows program, it
is 'portNo'. For NetWare program, it is
'portType, boardNo, portNo'. For UNIX, it is 'device name'.
Parsed from file SYNSO-UPSMIB.mib
Module: SYNSO-UPSMIB
syupsUpsComPort OBJECT-TYPE SYNTAX DisplayString (SIZE (0..31)) ACCESS read-write STATUS mandatory DESCRIPTION "The serial port which the UPS software use to communicate with the UPS. The format varies from platform to platform. For DOS program, the format is 'portNo, portAddress, portIRQ' (e.g. '1, 0x2f8, 3' for COM2). For Windows program, it is 'portNo'. For NetWare program, it is 'portType, boardNo, portNo'. For UNIX, it is 'device name'." ::= {syupsBasicSetting 6}
syupsUpsComPort OBJECT-TYPE SYNTAX DisplayString (SIZE (0..31)) ACCESS read-write STATUS mandatory DESCRIPTION "The serial port which the UPS software use to communicate with the UPS. The format varies from platform to platform. For DOS program, the format is 'portNo, portAddress, portIRQ' (e.g. '1, 0x2f8, 3' for COM2). For Windows program, it is 'portNo'. For NetWare program, it is 'portType, boardNo, portNo'. For UNIX, it is 'device name'." ::= {syupsBasicSetting 6}
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.9557.1.1.1 | syupsPlatForm | 0 | 0 | The platform which the UPS software is running on. |
1.3.6.1.4.1.9557.1.1.2 | syupsFeatureTable | 1 | 3 | A table containing the supported features. |
1.3.6.1.4.1.9557.1.1.3 | syupsSystemStartTime | 0 | 0 | The time that the UPS software starts. It is the number of seconds elapsed since 00:00:00, January 1, 1970. |
1.3.6.1.4.1.9557.1.1.4 | syupsSignalType | 0 | 0 | The signaling method between the UPS and software. When the basicSignal used, the UPS changes the voltage level of some specific … |
1.3.6.1.4.1.9557.1.1.5 | syupsBasicSignalDefinition | 0 | 0 | The signal definitions for the basic signaling UPS. The value can be the following bit combinations: SG_POWER_FAILURE_ENABLE … |
1.3.6.1.4.1.9557.1.1.7 | syupsModemComPort | 0 | 0 | The serial port which the UPS software use to dial out when some particular events occur. The format varies from platform to pla… |