syupsUpsExtension OBJECT IDENTIFIER ::= {synsoUpsSoftware 2}
syupsUpsExtension OBJECT IDENTIFIER ::= {synsoUpsSoftware 2}
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.9557.1.2.1 | syupsUpsAlarm | 0 | 0 | It is used internally. Each bit indicates a critical event, such as input bad, on battery, communications lost, ...,etc. |
1.3.6.1.4.1.9557.1.2.2 | syupsSerialNo | 0 | 0 | The serial number of the UPS connected to the UPS software. |
1.3.6.1.4.1.9557.1.2.3 | syupsConfigBatteryVoltage | 0 | 0 | The nominal battery voltage. |
1.3.6.1.4.1.9557.1.2.4 | syupsBatteryReplaceDate | 0 | 0 | The last battery replacement date. It represents the number of days elapsed since January 1, 1901. |
1.3.6.1.4.1.9557.1.2.5 | syupsNoOutlet | 0 | 0 | The total number of controllable outlets. |
1.3.6.1.4.1.9557.1.2.6 | syupsOutletParamter | 0 | 0 | This object is not used any more. |
1.3.6.1.4.1.9557.1.2.7 | syupsShutdownDepend | 0 | 0 | A string containing those who should perform their shutdown procedure before the UPS turns off. The agent will inform each one in… |
1.3.6.1.4.1.9557.1.2.8 | syupsEnableAutoSave | 0 | 0 | Setting it to 1, the agent will try to save all files opened by applications before shutting down the operation system. Setting … |
1.3.6.1.4.1.9557.1.2.9 | syupsShutdownOsDelay | 0 | 0 | The delay time before shutting down the operation system. When it is necessary to shut down the operation system, the agent will … |
1.3.6.1.4.1.9557.1.2.10 | syupsShutdownUpsDelay | 0 | 0 | The delay time before shutting down the UPS. Before shutting down the operation system, the agent will send a command to tell th… |
1.3.6.1.4.1.9557.1.2.11 | syupsSaveConfig | 0 | 0 | Used to inform the agnet to save the configurations. Its value indicates which group to be saved. For example, a 1 indicates gr… |
1.3.6.1.4.1.9557.1.2.12 | syupsNoOutlets | 0 | 0 | The number of controllable outlets. |
1.3.6.1.4.1.9557.1.2.13 | syupsOutletTable | 1 | 5 | A list of outlet table entries. The number of entries is given by the value of syupsNoOutlets. |
1.3.6.1.4.1.9557.1.2.14 | syupsOutletOperator | 0 | 0 | The operator is used to control the outlets. There are two commands: 1. 'SWITCH: OutletNo, OnOff'. The OutletNo specify the outle… |
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.9557.1.1 | syupsBasicSetting | 7 | 10 | None |
1.3.6.1.4.1.9557.1.3 | syupsEventAction | 2 | 23 | None |
1.3.6.1.4.1.9557.1.4 | syupsHistory | 9 | 15 | None |
1.3.6.1.4.1.9557.1.5 | syupsSchedule | 3 | 10 | None |
1.3.6.1.4.1.9557.1.6 | syupsCoworker | 6 | 12 | None |
1.3.6.1.4.1.9557.1.7 | syupsTraps | 7 | 7 | None |