Reference record for OID 0.4.0.304.0.6.17

Parent
0.4.0.304.0.6 (etsNameBinding)
Node code
17
Node name
etsCrossConnection-mpCrossConnection
Numeric OID
0.4.0.304.0.6.17
URN notation
urn:oid:0.4.0.304.0.6.17
ASN.1 notation

{0 4 0 304 0 6 17}

  • {itu-t(0) identified-organization(4) etsi(0) 304 prETS300304(0) etsNameBinding(6) etsCrossConnection-mpCrossConnection(17)}
  • {itu-t(0) identified-organization(4) oidETSI(0) 304 prETS300304(0) etsNameBinding(6) etsCrossConnection-mpCrossConnection(17)}
  • {itu-t(0) identified-organization(4) etsiPrefix(0) 304 prETS300304(0) etsNameBinding(6) etsCrossConnection-mpCrossConnection(17)}
  • {ccitt(0) identified-organization(4) etsi(0) 304 prETS300304(0) etsNameBinding(6) etsCrossConnection-mpCrossConnection(17)}
  • {ccitt(0) identified-organization(4) oidETSI(0) 304 prETS300304(0) etsNameBinding(6) etsCrossConnection-mpCrossConnection(17)}
  • {ccitt(0) identified-organization(4) etsiPrefix(0) 304 prETS300304(0) etsNameBinding(6) etsCrossConnection-mpCrossConnection(17)}
OID-IRI notation
  • /0/4/0/304/0/6/17
  • /ITU-T/Identified-Organization/0/304/0/6/17
  • /ITU-T/4/0/304/0/6/17
Named path variants
  • /itu-t/identified-organization/etsi/304/prETS300304/etsNameBinding/etsCrossConnection-mpCrossConnection
  • /itu-t/identified-organization/oidETSI/304/prETS300304/etsNameBinding/etsCrossConnection-mpCrossConnection
  • /itu-t/identified-organization/etsiPrefix/304/prETS300304/etsNameBinding/etsCrossConnection-mpCrossConnection
  • /ccitt/identified-organization/etsi/304/prETS300304/etsNameBinding/etsCrossConnection-mpCrossConnection
  • /ccitt/identified-organization/oidETSI/304/prETS300304/etsNameBinding/etsCrossConnection-mpCrossConnection
  • /ccitt/identified-organization/etsiPrefix/304/prETS300304/etsNameBinding/etsCrossConnection-mpCrossConnection

Descriptions

etsCrossConnection-mpCrossConnection — ETSI published formal attachments

This object class is used specifically for representing an equipment protection group in a protection system. The invokeProtection action switches always from protectedUnit to protectingUnit. Either no or all equipmentProtectionUnits within an equipmentProtectionGroup shall have the priorityPkg package.

Source records

etsCrossConnection-mpCrossConnection

Status in source: unspecified.

Names: etsCrossConnection-mpCrossConnection

Technical details
{
  "gdmo_kind": "NAME BINDING",
  "definition": [
    "etsCrossConnection-mpCrossConnection",
    "NAME",
    "BINDING",
    "SUBORDINATE",
    "OBJECT",
    "CLASS",
    [
      "literal",
      "225265636f6d6d656e646174696f6e204d2e3331303022"
    ],
    ":",
    "crossConnection",
    "AND",
    "SUBCLASSES",
    ";",
    "NAMED",
    "BY",
    "SUPERIOR",
    "OBJECT",
    "CLASS",
    [
      "literal",
      "225265636f6d6d656e646174696f6e204d2e3331303022"
    ],
    ":",
    "mpCrossConnection",
    "AND",
    "SUBCLASSES",
    ";",
    "WITH",
    "ATTRIBUTE",
    [
      "literal",
      "225265636f6d6d656e646174696f6e204d2e3331303022"
    ],
    ":",
    "crossConnectionId",
    ";",
    "BEHAVIOUR",
    "etsCrossConnection-mpCrossConnectionBehaviour",
    "BEHAVIOUR",
    "DEFINED",
    "AS",
    "*",
    "The",
    "value",
    "of",
    "the",
    "fromTermination",
    "attribute",
    "in",
    "the",
    "crossConnection",
    "object",
    "must",
    "be",
    "NULL",
    ".",
    "When",
    "an",
    "instance",
    "of",
    "crossConnection",
    "is",
    "deleted",
    ",",
    "the",
    "following",
    "attributes",
    "will",
    "be",
    "affected",
    ".",
    "The",
    "crossConnectionObjectPointer",
    "attributes",
    "in",
    "the",
    "termination",
    "points",
    "or",
    "in",
    "the",
    "gtp",
    "objects",
    "that",
    "were",
    "pointing",
    "to",
    "the",
    "deleted",
    "crossConnection",
    "instance",
    "shall",
    "be",
    "set",
    "to",
    "point",
    "to",
    "the",
    "Fabric",
    "responsible",
    "for",
    "the",
    "connection",
    "of",
    "the",
    "termination",
    "points",
    ".",
    "The",
    "counters",
    "in",
    "the",
    "appropriate",
    "TP",
    "Pool",
    "objects",
    "(",
    "if",
    "applicable",
    ")",
    "shall",
    "be",
    "updated",
    ".",
    "The",
    "connectivityPointer",
    "attributes",
    "in",
    "the",
    "disconnected",
    "termination",
    "points",
    "shall",
    "be",
    "set",
    "to",
    "NULL",
    ".",
    "Deleting",
    "the",
    "last",
    "cross-Connection",
    "contained",
    "in",
    "a",
    "multipoint",
    "cross",
    "connection",
    "object",
    "has",
    "the",
    "effect",
    "of",
    "also",
    "deleting",
    "the",
    "multipoint",
    "cross",
    "connection",
    "object",
    "instance",
    "(",
    "and",
    "updating",
    "the",
    "appropriate",
    "pointers",
    ")",
    ".",
    "Deleting",
    "a",
    "crossConnection",
    "object",
    "instance",
    "has",
    "no",
    "effect",
    "on",
    "the",
    "composition",
    "of",
    "any",
    "GTP",
    "*",
    ";",
    ";",
    "REGISTERED",
    "AS",
    "{",
    "etsNameBinding",
    "17",
    "}",
    ";"
  ]
}
  • ETSI published formal attachments · Publisher's source file: Source package: ets_300304e02p0.zip
    Published definition
    etsCrossConnection-mpCrossConnection NAME BINDING
    SUBORDINATE OBJECT CLASS "Recommendation M.3100":crossConnection
      AND SUBCLASSES;
    NAMED BY
    SUPERIOR OBJECT CLASS    "Recommendation M.3100":mpCrossConnection
      AND SUBCLASSES;
    WITH ATTRIBUTE           "Recommendation M.3100":crossConnectionId;
    BEHAVIOUR
      etsCrossConnection-mpCrossConnectionBehaviour BEHAVIOUR
         DEFINED AS
    *The value of the fromTermination attribute in the  crossConnection object must be NULL. When an instance of crossConnection is deleted, the following attributes will be affected. The crossConnectionObjectPointer attributes in the termination points or in the gtp objects that were pointing to the deleted crossConnection instance shall be set to point to the Fabric responsible for the connection of the termination points. The counters in the appropriate TP Pool objects (if applicable) shall be updated. The connectivityPointer attributes in the disconnected termination points shall be set to NULL. Deleting the last cross-Connection contained in a multipoint cross connection object has the effect of also deleting the multipoint cross connection object instance (and updating the appropriate pointers). Deleting a crossConnection object instance has no effect on the composition of any GTP*
    ;;
    REGISTERED AS {etsNameBinding 17 };
    · Download ETSI ETS 300 304 — Transmission and Multiplexing (TM); Synchronous Digital Hierarchy (SDH); SDH information model for the Network Element (NE) view (DE20304.TXT)
    Source location: GDMO::etsCrossConnection-mpCrossConnection.
    Source version and references

    Published package: ETSI ETS 300 304 edition-02; file: DE20304.TXT.

    Downloaded: 2026-10-29T11:18:23.194992+00:00.

Current Registration Authority (inferred from ancestor 0.4.0)

Anthony Wiles

Siblings (13)

OIDNameDirect childrenDescendantsDescription
0.4.0.304.0.6.16 etsCrossConnection-fabric00
0.4.0.304.0.6.18 powerSupply-sdhNE00
0.4.0.304.0.6.19 timingGenerator-sdhNE00
0.4.0.304.0.6.20 p12CTPSource-G774vc12TTPSource00
0.4.0.304.0.6.21 p12CTPSink-G774vc12TTPSink00
0.4.0.304.0.6.22 p31CTPSource-G774vc3TTPSource00
0.4.0.304.0.6.23 p31CTPSink-G774vc3TTPSink00
0.4.0.304.0.6.24 p4CTPSource-G774vc4TTPSource00
0.4.0.304.0.6.25 p4CTPSink-G774vc4TTPSink00
0.4.0.304.0.6.26 equipmentProtectionUnitPkg00
0.4.0.304.0.6.27 timingPhysicalTerminationBidirectional-sdhNE00
0.4.0.304.0.6.28 timingPhysicalTerminationSink-sdhNE00
0.4.0.304.0.6.29 timingPhysicalTerminationSource-sdhNE00