Reference record for OID 1.3.111.2.802.1.1.26.1.4.1.4

Parent
1.3.111.2.802.1.1.26.1.4.1 (ieee8021SpbEctStaticTableEntry)
Node code
4
Node name
ieee8021SpbvEctStaticEntrySpvid
Numeric OID
1.3.111.2.802.1.1.26.1.4.1.4
URN notation
urn:oid:1.3.111.2.802.1.1.26.1.4.1.4
ASN.1 notation

{1 3 111 2 802 1 1 26 1 4 1 4}

  • {iso(1) identified-organization(3) ieee(111) standards-association-numbered-series-standards(2) lan-man-stds(802) ieee802dot1(1) ieee802dot1mibs(1) ieee8021SpbMib(26) ieee8021SpbObjects(1) ieee8021SpbEctStaticTable(4) ieee8021SpbEctStaticTableEntry(1) ieee8021SpbvEctStaticEntrySpvid(4)}
  • {iso(1) identified-organization(3) ieee(111) standards-association-numbers-series-standards(2) lan-man-stds(802) ieee802dot1(1) ieee802dot1mibs(1) ieee8021SpbMib(26) ieee8021SpbObjects(1) ieee8021SpbEctStaticTable(4) ieee8021SpbEctStaticTableEntry(1) ieee8021SpbvEctStaticEntrySpvid(4)}
  • {iso(1) org(3) ieee(111) standards-association-numbered-series-standards(2) lan-man-stds(802) ieee802dot1(1) ieee802dot1mibs(1) ieee8021SpbMib(26) ieee8021SpbObjects(1) ieee8021SpbEctStaticTable(4) ieee8021SpbEctStaticTableEntry(1) ieee8021SpbvEctStaticEntrySpvid(4)}
  • {iso(1) org(3) ieee(111) standards-association-numbers-series-standards(2) lan-man-stds(802) ieee802dot1(1) ieee802dot1mibs(1) ieee8021SpbMib(26) ieee8021SpbObjects(1) ieee8021SpbEctStaticTable(4) ieee8021SpbEctStaticTableEntry(1) ieee8021SpbvEctStaticEntrySpvid(4)}
  • {iso(1) iso-identified-organization(3) ieee(111) standards-association-numbered-series-standards(2) lan-man-stds(802) ieee802dot1(1) ieee802dot1mibs(1) ieee8021SpbMib(26) ieee8021SpbObjects(1) ieee8021SpbEctStaticTable(4) ieee8021SpbEctStaticTableEntry(1) ieee8021SpbvEctStaticEntrySpvid(4)}
  • {iso(1) iso-identified-organization(3) ieee(111) standards-association-numbers-series-standards(2) lan-man-stds(802) ieee802dot1(1) ieee802dot1mibs(1) ieee8021SpbMib(26) ieee8021SpbObjects(1) ieee8021SpbEctStaticTable(4) ieee8021SpbEctStaticTableEntry(1) ieee8021SpbvEctStaticEntrySpvid(4)}
  • {iso(1) iso-organization(3) ieee(111) standards-association-numbered-series-standards(2) lan-man-stds(802) ieee802dot1(1) ieee802dot1mibs(1) ieee8021SpbMib(26) ieee8021SpbObjects(1) ieee8021SpbEctStaticTable(4) ieee8021SpbEctStaticTableEntry(1) ieee8021SpbvEctStaticEntrySpvid(4)}
  • {iso(1) iso-organization(3) ieee(111) standards-association-numbers-series-standards(2) lan-man-stds(802) ieee802dot1(1) ieee802dot1mibs(1) ieee8021SpbMib(26) ieee8021SpbObjects(1) ieee8021SpbEctStaticTable(4) ieee8021SpbEctStaticTableEntry(1) ieee8021SpbvEctStaticEntrySpvid(4)}
OID-IRI notation
  • /1/3/111/2/802/1/1/26/1/4/1/4
  • /ISO/Identified-Organization/111/2/802/1/1/26/1/4/1/4
  • /ISO/3/111/2/802/1/1/26/1/4/1/4
Named path variants
  • /iso/identified-organization/ieee/standards-association-numbered-series-standards/lan-man-stds/ieee802dot1/ieee802dot1mibs/ieee8021SpbMib/ieee8021SpbObjects/ieee8021SpbEctStaticTable/ieee8021SpbEctStaticTableEntry/ieee8021SpbvEctStaticEntrySpvid
  • /iso/identified-organization/ieee/standards-association-numbers-series-standards/lan-man-stds/ieee802dot1/ieee802dot1mibs/ieee8021SpbMib/ieee8021SpbObjects/ieee8021SpbEctStaticTable/ieee8021SpbEctStaticTableEntry/ieee8021SpbvEctStaticEntrySpvid
  • /iso/org/ieee/standards-association-numbered-series-standards/lan-man-stds/ieee802dot1/ieee802dot1mibs/ieee8021SpbMib/ieee8021SpbObjects/ieee8021SpbEctStaticTable/ieee8021SpbEctStaticTableEntry/ieee8021SpbvEctStaticEntrySpvid
  • /iso/org/ieee/standards-association-numbers-series-standards/lan-man-stds/ieee802dot1/ieee802dot1mibs/ieee8021SpbMib/ieee8021SpbObjects/ieee8021SpbEctStaticTable/ieee8021SpbEctStaticTableEntry/ieee8021SpbvEctStaticEntrySpvid
  • /iso/iso-identified-organization/ieee/standards-association-numbered-series-standards/lan-man-stds/ieee802dot1/ieee802dot1mibs/ieee8021SpbMib/ieee8021SpbObjects/ieee8021SpbEctStaticTable/ieee8021SpbEctStaticTableEntry/ieee8021SpbvEctStaticEntrySpvid
  • /iso/iso-identified-organization/ieee/standards-association-numbers-series-standards/lan-man-stds/ieee802dot1/ieee802dot1mibs/ieee8021SpbMib/ieee8021SpbObjects/ieee8021SpbEctStaticTable/ieee8021SpbEctStaticTableEntry/ieee8021SpbvEctStaticEntrySpvid
  • /iso/iso-organization/ieee/standards-association-numbered-series-standards/lan-man-stds/ieee802dot1/ieee802dot1mibs/ieee8021SpbMib/ieee8021SpbObjects/ieee8021SpbEctStaticTable/ieee8021SpbEctStaticTableEntry/ieee8021SpbvEctStaticEntrySpvid
  • /iso/iso-organization/ieee/standards-association-numbers-series-standards/lan-man-stds/ieee802dot1/ieee802dot1mibs/ieee8021SpbMib/ieee8021SpbObjects/ieee8021SpbEctStaticTable/ieee8021SpbEctStaticTableEntry/ieee8021SpbvEctStaticEntrySpvid

Source records

If SPBV mode this is the VID originating from this bridge. This input is ignored if ieee8021SpbvSysMode is auto(1), but the output always returns the SPVID in use. Otherwise in SPBM this is empty, should be set = 0. This object is persistent.

Status in source: current.

Names: ieee8021SpbvEctStaticEntrySpvid

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "ieee8021SpbvEctStaticEntrySpvid",
    "OBJECT-TYPE",
    "SYNTAX",
    "VlanIdOrNone",
    "MAX-ACCESS",
    "read-create",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"If SPBV mode this is the VID originating from this bridge. This input is ignored if ieee8021SpbvSysMode is auto(1), but the output always returns the SPVID in use. Otherwise in SPBM this is empty, should be set = 0. This object is persistent.\"",
    "REFERENCE",
    "\"12.25.4.2.3, 3.252\"",
    "::=",
    "{",
    "ieee8021SpbEctStaticTableEntry",
    "4",
    "}"
  ],
  "syntax_tree": [
    [
      "row",
      "VlanIdOrNone"
    ],
    null,
    [
      "MaxAccessPart",
      "read-create"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "If SPBV mode this is the VID originating from this bridge. This input is ignored if ieee8021SpbvSysMode is auto(1), but the output always returns the SPVID in use. Otherwise in SPBM this is empty, should be set = 0. This object is persistent."
    ],
    [
      "REFERENCE",
      "12.25.4.2.3, 3.252"
    ],
    null,
    null,
    null
  ]
}
  • IEEE 802 · Publisher's source file · Archived source file
    Source location: IEEE8021-SPB-MIB::ieee8021SpbvEctStaticEntrySpvid.
    Source version and references

    Downloaded: 2026-10-19T00:21:52.339861+00:00. SHA-256: f2dc93398bd1c79db499d2ef333833c4e452000199768845e8ef0d3e0aea4607

    {'kind': 'OBJECT-TYPE', 'details': {'module': 'IEEE8021-SPB-MIB', 'imports': {'IF-MIB': ['InterfaceIndexOrZero'], 'SNMPv2-TC': ['RowStatus', 'MacAddress', 'TruthValue', 'TEXTUAL-CONVENTION'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Integer32', 'Unsigned32'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP'], 'Q-BRIDGE-MIB': ['VlanId', 'VlanIdOrNone', 'VlanIdOrAny'], 'IEEE8021-TC-MIB': ['ieee802dot1mibs', 'IEEE8021PbbIngressEgress', 'IEEE8021BridgePortNumber', 'IEEE8021PbbServiceIdentifier', 'IEEE8021PbbTeEsp'], 'IEEE8021-CFM-MIB': ['dot1agCfmMepEntry', 'dot1agCfmMdIndex', 'dot1agCfmMaIndex'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString'], 'IEEE8021-BRIDGE-MIB': ['ieee8021BridgeBasePort']}, 'smi_kind': 'OBJECT-TYPE', 'definition': 'ieee8021SpbvEctStaticEntrySpvid OBJECT-TYPE\n\tSYNTAX VlanIdOrNone\n\tMAX-ACCESS read-create\n\tSTATUS current\n\tDESCRIPTION\n\t\t"If SPBV mode this is the VID originating from this bridge.\n\t\t This input is ignored if ieee8021SpbvSysMode is auto(1),\n\t\t but the output always returns the SPVID in use.\n\t\t Otherwise in SPBM this is empty, should be set = 0.\n\t\t This object is persistent."\n\tREFERENCE "12.25.4.2.3, 3.252"\n\t::= { ieee8021SpbEctStaticTableEntry 4 }', 'syntax_tree': [['row', 'VlanIdOrNone'], None, ['MaxAccessPart', 'read-create'], ['Status', 'current'], ['DESCRIPTION', 'If SPBV mode this is the VID originating from this bridge. This input is ignored if ieee8021SpbvSysMode is auto(1), but the output always returns the SPVID in use. Otherwise in SPBM this is empty, should be set = 0. This object is persistent.'], ['REFERENCE', '12.25.4.2.3, 3.252'], None, None, None], 'source_encoding': 'utf-8-sig'}, 'parser_version': 'mib-4'}

If SPBV mode this is the VID originating from this bridge. This input is ignored if ieee8021SpbvSysMode is auto(1), but the output always returns the SPVID in use. Otherwise in SPBM this is empty, should be set = 0. This object is persistent.

Status in source: current.

Names: ieee8021SpbvEctStaticEntrySpvid

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "ieee8021SpbvEctStaticEntrySpvid",
    "OBJECT-TYPE",
    "SYNTAX",
    "VlanIdOrNone",
    "MAX-ACCESS",
    "read-create",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"If SPBV mode this is the VID originating from this bridge. This input is ignored if ieee8021SpbvSysMode is auto(1), but the output always returns the SPVID in use. Otherwise in SPBM this is empty, should be set = 0. This object is persistent.\"",
    "REFERENCE",
    "\"12.25.4.2.3, 3.246\"",
    "::=",
    "{",
    "ieee8021SpbEctStaticTableEntry",
    "4",
    "}"
  ],
  "syntax_tree": [
    [
      "row",
      "VlanIdOrNone"
    ],
    null,
    [
      "MaxAccessPart",
      "read-create"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "If SPBV mode this is the VID originating from this bridge. This input is ignored if ieee8021SpbvSysMode is auto(1), but the output always returns the SPVID in use. Otherwise in SPBM this is empty, should be set = 0. This object is persistent."
    ],
    [
      "REFERENCE",
      "12.25.4.2.3, 3.246"
    ],
    null,
    null,
    null
  ]
}
  • IEEE 802 · Publisher's source file · Archived source file
    Source location: IEEE8021-SPB-MIB::ieee8021SpbvEctStaticEntrySpvid.
    Source version and references

    Downloaded: 2026-10-19T00:20:40.988079+00:00. SHA-256: c19b6da19ad597df3b79053ec62dd6368b6d6d02adb13e1504f315941e1bedf9

    {'kind': 'OBJECT-TYPE', 'details': {'module': 'IEEE8021-SPB-MIB', 'imports': {'IF-MIB': ['InterfaceIndexOrZero'], 'SNMPv2-TC': ['RowStatus', 'MacAddress', 'TruthValue', 'TEXTUAL-CONVENTION'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Integer32', 'Unsigned32'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP'], 'Q-BRIDGE-MIB': ['VlanId', 'VlanIdOrNone', 'VlanIdOrAny'], 'IEEE8021-TC-MIB': ['ieee802dot1mibs', 'IEEE8021PbbIngressEgress', 'IEEE8021BridgePortNumber', 'IEEE8021PbbServiceIdentifier', 'IEEE8021PbbTeEsp'], 'IEEE8021-CFM-MIB': ['dot1agCfmMepEntry', 'dot1agCfmMdIndex', 'dot1agCfmMaIndex'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString'], 'IEEE8021-BRIDGE-MIB': ['ieee8021BridgeBasePort']}, 'smi_kind': 'OBJECT-TYPE', 'definition': 'ieee8021SpbvEctStaticEntrySpvid OBJECT-TYPE\r\n\tSYNTAX VlanIdOrNone\r\n\tMAX-ACCESS read-create\r\n\tSTATUS current\r\n\tDESCRIPTION\r\n\t\t"If SPBV mode this is the VID originating from this bridge.\r\n\t\t This input is ignored if ieee8021SpbvSysMode is auto(1),\r\n\t\t but the output always returns the SPVID in use.\r\n\t\t Otherwise in SPBM this is empty, should be set = 0.\r\n\t\t This object is persistent."\r\n\tREFERENCE "12.25.4.2.3, 3.246"\r\n\t::= { ieee8021SpbEctStaticTableEntry 4 }', 'syntax_tree': [['row', 'VlanIdOrNone'], None, ['MaxAccessPart', 'read-create'], ['Status', 'current'], ['DESCRIPTION', 'If SPBV mode this is the VID originating from this bridge. This input is ignored if ieee8021SpbvSysMode is auto(1), but the output always returns the SPVID in use. Otherwise in SPBM this is empty, should be set = 0. This object is persistent.'], ['REFERENCE', '12.25.4.2.3, 3.246'], None, None, None], 'source_encoding': 'utf-8-sig'}, 'parser_version': 'mib-4'}

If SPBV mode this is the VID originating from this Bridge. This input is ignored if ieee8021SpbvSysMode is auto(1), but the output always returns the SPVID in use. Otherwise in SPBM this is empty, should be set = 0. This object is persistent.

Status in source: current.

Names: ieee8021SpbvEctStaticEntrySpvid

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "ieee8021SpbvEctStaticEntrySpvid",
    "OBJECT-TYPE",
    "SYNTAX",
    "VlanIdOrNone",
    "MAX-ACCESS",
    "read-create",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"If SPBV mode this is the VID originating from this Bridge. This input is ignored if ieee8021SpbvSysMode is auto(1), but the output always returns the SPVID in use. Otherwise in SPBM this is empty, should be set = 0. This object is persistent.\"",
    "REFERENCE",
    "\"12.25.4.2.3, 3.217\"",
    "::=",
    "{",
    "ieee8021SpbEctStaticTableEntry",
    "4",
    "}"
  ],
  "syntax_tree": [
    [
      "row",
      "VlanIdOrNone"
    ],
    null,
    [
      "MaxAccessPart",
      "read-create"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "If SPBV mode this is the VID originating from this Bridge. This input is ignored if ieee8021SpbvSysMode is auto(1), but the output always returns the SPVID in use. Otherwise in SPBM this is empty, should be set = 0. This object is persistent."
    ],
    [
      "REFERENCE",
      "12.25.4.2.3, 3.217"
    ],
    null,
    null,
    null
  ]
}
  • IEEE 802 · Publisher's source file · Archived source file
    Source location: IEEE8021-SPB-MIB::ieee8021SpbvEctStaticEntrySpvid.
    Source version and references

    Downloaded: 2026-10-19T00:20:39.090781+00:00. SHA-256: 30cd348d55040e409237cac2cc6e4a868364151e21689cfab34350a4d5d2962c

    {'kind': 'OBJECT-TYPE', 'details': {'module': 'IEEE8021-SPB-MIB', 'imports': {'IF-MIB': ['InterfaceIndexOrZero'], 'SNMPv2-TC': ['RowStatus', 'MacAddress', 'TruthValue', 'TEXTUAL-CONVENTION'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Integer32', 'Unsigned32'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP'], 'Q-BRIDGE-MIB': ['VlanId', 'VlanIdOrNone', 'VlanIdOrAny'], 'IEEE8021-TC-MIB': ['ieee802dot1mibs', 'IEEE8021PbbIngressEgress', 'IEEE8021BridgePortNumber', 'IEEE8021PbbServiceIdentifier', 'IEEE8021PbbTeEsp'], 'IEEE8021-CFM-MIB': ['dot1agCfmMepEntry', 'dot1agCfmMdIndex', 'dot1agCfmMaIndex'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString'], 'IEEE8021-BRIDGE-MIB': ['ieee8021BridgeBasePort']}, 'smi_kind': 'OBJECT-TYPE', 'definition': 'ieee8021SpbvEctStaticEntrySpvid OBJECT-TYPE\r\n    SYNTAX VlanIdOrNone\r\n    MAX-ACCESS read-create\r\n    STATUS current\r\n    DESCRIPTION\r\n        "If SPBV mode this is the VID originating from this Bridge.\r\n         This input is ignored if ieee8021SpbvSysMode is auto(1),\r\n         but the output always returns the SPVID in use.\r\n         Otherwise in SPBM this is empty, should be set = 0.\r\n         This object is persistent."\r\n    REFERENCE "12.25.4.2.3, 3.217"\r\n    ::= { ieee8021SpbEctStaticTableEntry 4 }', 'syntax_tree': [['row', 'VlanIdOrNone'], None, ['MaxAccessPart', 'read-create'], ['Status', 'current'], ['DESCRIPTION', 'If SPBV mode this is the VID originating from this Bridge. This input is ignored if ieee8021SpbvSysMode is auto(1), but the output always returns the SPVID in use. Otherwise in SPBM this is empty, should be set = 0. This object is persistent.'], ['REFERENCE', '12.25.4.2.3, 3.217'], None, None, None], 'source_encoding': 'utf-8-sig'}, 'parser_version': 'mib-4'}

If SPBV mode this is the VID originating from this bridge. This input is ignored if ieee8021SpbvSysMode is auto(1), but the output always returns the SPVID in use. Otherwise in SPBM this is empty, should be set = 0. This object is persistent.

Status in source: current.

Names: ieee8021SpbvEctStaticEntrySpvid

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "ieee8021SpbvEctStaticEntrySpvid",
    "OBJECT-TYPE",
    "SYNTAX",
    "VlanIdOrNone",
    "MAX-ACCESS",
    "read-create",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"If SPBV mode this is the VID originating from this bridge. This input is ignored if ieee8021SpbvSysMode is auto(1), but the output always returns the SPVID in use. Otherwise in SPBM this is empty, should be set = 0. This object is persistent.\"",
    "REFERENCE",
    "\"12.25.4.2.3, 3.16\"",
    "::=",
    "{",
    "ieee8021SpbEctStaticTableEntry",
    "4",
    "}"
  ],
  "syntax_tree": [
    [
      "row",
      "VlanIdOrNone"
    ],
    null,
    [
      "MaxAccessPart",
      "read-create"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "If SPBV mode this is the VID originating from this bridge. This input is ignored if ieee8021SpbvSysMode is auto(1), but the output always returns the SPVID in use. Otherwise in SPBM this is empty, should be set = 0. This object is persistent."
    ],
    [
      "REFERENCE",
      "12.25.4.2.3, 3.16"
    ],
    null,
    null,
    null
  ]
}
  • IEEE 802 · Publisher's source file · Archived source file
    Source location: IEEE8021-SPB-MIB::ieee8021SpbvEctStaticEntrySpvid.
    Source version and references

    Downloaded: 2026-10-19T00:20:38.211682+00:00. SHA-256: 5ede1d3fb97b474c1bad687e60ea29f63bea20ee41a0d42bfa3d449c45b84f99

    {'kind': 'OBJECT-TYPE', 'details': {'module': 'IEEE8021-SPB-MIB', 'imports': {'IF-MIB': ['InterfaceIndexOrZero'], 'SNMPv2-TC': ['RowStatus', 'MacAddress', 'TruthValue', 'TEXTUAL-CONVENTION'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Integer32', 'Unsigned32'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP'], 'Q-BRIDGE-MIB': ['VlanId', 'VlanIdOrNone', 'VlanIdOrAny'], 'IEEE8021-TC-MIB': ['ieee802dot1mibs', 'IEEE8021PbbIngressEgress', 'IEEE8021BridgePortNumber'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}, 'smi_kind': 'OBJECT-TYPE', 'definition': 'ieee8021SpbvEctStaticEntrySpvid OBJECT-TYPE\n\tSYNTAX VlanIdOrNone\n\tMAX-ACCESS read-create\n\tSTATUS current\n\tDESCRIPTION\n\t\t"If SPBV mode this is the VID originating from this bridge.\n\t\t This input is ignored if ieee8021SpbvSysMode is auto(1),\n\t\t but the output always returns the SPVID in use.\n\t\t Otherwise in SPBM this is empty, should be set = 0.\n\t\t This object is persistent."\n\tREFERENCE "12.25.4.2.3, 3.16"\n\t::= { ieee8021SpbEctStaticTableEntry 4 }', 'syntax_tree': [['row', 'VlanIdOrNone'], None, ['MaxAccessPart', 'read-create'], ['Status', 'current'], ['DESCRIPTION', 'If SPBV mode this is the VID originating from this bridge. This input is ignored if ieee8021SpbvSysMode is auto(1), but the output always returns the SPVID in use. Otherwise in SPBM this is empty, should be set = 0. This object is persistent.'], ['REFERENCE', '12.25.4.2.3, 3.16'], None, None, None], 'source_encoding': 'utf-8-sig'}, 'parser_version': 'mib-4'}
  • IEEE 802 · Publisher's source file · Archived source file
    Source location: IEEE8021-SPB-MIB::ieee8021SpbvEctStaticEntrySpvid.
    Source version and references

    Downloaded: 2026-10-19T00:20:40.023796+00:00. SHA-256: 0a4998a94b8686b110f8d9c36555055e0960607467f3f4d020bae9b865a0cb6f

    {'kind': 'OBJECT-TYPE', 'details': {'module': 'IEEE8021-SPB-MIB', 'imports': {'IF-MIB': ['InterfaceIndexOrZero'], 'SNMPv2-TC': ['RowStatus', 'MacAddress', 'TruthValue', 'TEXTUAL-CONVENTION'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Integer32', 'Unsigned32'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP'], 'Q-BRIDGE-MIB': ['VlanId', 'VlanIdOrNone', 'VlanIdOrAny'], 'IEEE8021-TC-MIB': ['ieee802dot1mibs', 'IEEE8021PbbIngressEgress', 'IEEE8021BridgePortNumber', 'IEEE8021PbbServiceIdentifier', 'IEEE8021PbbTeEsp'], 'IEEE8021-CFM-MIB': ['dot1agCfmMepEntry', 'dot1agCfmMdIndex', 'dot1agCfmMaIndex'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString'], 'IEEE8021-BRIDGE-MIB': ['ieee8021BridgeBasePort']}, 'smi_kind': 'OBJECT-TYPE', 'definition': 'ieee8021SpbvEctStaticEntrySpvid OBJECT-TYPE\r\n\tSYNTAX VlanIdOrNone\r\n\tMAX-ACCESS read-create\r\n\tSTATUS current\r\n\tDESCRIPTION\r\n\t\t"If SPBV mode this is the VID originating from this bridge.\r\n\t\t This input is ignored if ieee8021SpbvSysMode is auto(1),\r\n\t\t but the output always returns the SPVID in use.\r\n\t\t Otherwise in SPBM this is empty, should be set = 0.\r\n\t\t This object is persistent."\r\n\tREFERENCE "12.25.4.2.3, 3.16"\r\n\t::= { ieee8021SpbEctStaticTableEntry 4 }', 'syntax_tree': [['row', 'VlanIdOrNone'], None, ['MaxAccessPart', 'read-create'], ['Status', 'current'], ['DESCRIPTION', 'If SPBV mode this is the VID originating from this bridge. This input is ignored if ieee8021SpbvSysMode is auto(1), but the output always returns the SPVID in use. Otherwise in SPBM this is empty, should be set = 0. This object is persistent.'], ['REFERENCE', '12.25.4.2.3, 3.16'], None, None, None], 'source_encoding': 'utf-8-sig'}, 'parser_version': 'mib-4'}

Current Registration Authority (inferred from ancestor 1.3)

Frank Farance

Siblings (4)

OIDNameDirect childrenDescendantsDescription
1.3.111.2.802.1.1.26.1.4.1.1 ieee8021SpbEctStaticEntryTopIx00
1.3.111.2.802.1.1.26.1.4.1.2 ieee8021SpbEctStaticEntryBaseVid00
1.3.111.2.802.1.1.26.1.4.1.3 ieee8021SpbEctStaticEntryEctAlgorithm00
1.3.111.2.802.1.1.26.1.4.1.5 ieee8021SpbEctStaticEntryRowStatus00