The compliance statement for support of the TEIPS MIB module.
Status in source: current.
Names: ieee8021TeipsV2Compliance
Technical details
{
"smi_kind": "MODULE-COMPLIANCE",
"definition": [
"ieee8021TeipsV2Compliance",
"MODULE-COMPLIANCE",
"STATUS",
"current",
"DESCRIPTION",
"\"The compliance statement for support of the TEIPS MIB module.\"",
"MODULE",
"MANDATORY-GROUPS",
"{",
"ieee8021TeipsV2IpgGroup",
",",
"ieee8021TeipsV2IpgTesiGroup",
",",
"ieee8021TeipsV2IpgConfigManGroup",
",",
"ieee8021TeipsV2NotificationsGroup",
"}",
"GROUP",
"ieee8021TeipsV2IpgConfigOptGroup",
"DESCRIPTION",
"\"This group allows implmementation to optionally change the WaitToRestore, M:1 WaitToRestore, and HoldOff timers for IPGs.\"",
"GROUP",
"ieee8021TeipsV2CandidatePsGroup",
"DESCRIPTION",
"\"This group allows implmementation to optionally list candidate Protection Segments when M:1 IPS is deployed.\"",
"OBJECT",
"ieee8021TeipsV2IpgConfigWTR",
"MIN-ACCESS",
"not-accessible",
"DESCRIPTION",
"\"This object is optional.\"",
"OBJECT",
"ieee8021TeipsV2IpgConfigHoldOff",
"MIN-ACCESS",
"not-accessible",
"DESCRIPTION",
"\"This object is optional.\"",
"OBJECT",
"ieee8021TeipsV2IpgConfigMWTR",
"MIN-ACCESS",
"not-accessible",
"DESCRIPTION",
"\"This object is optional.\"",
"OBJECT",
"ieee8021TeipsV2IpgRowStatus",
"SYNTAX",
"RowStatus",
"{",
"active",
"(",
"1",
")",
",",
"notInService",
"(",
"2",
")",
"}",
"WRITE-SYNTAX",
"RowStatus",
"{",
"notInService",
"(",
"2",
")",
",",
"createAndGo",
"(",
"4",
")",
",",
"destroy",
"(",
"6",
")",
"}",
"DESCRIPTION",
"\"Support for createAndWait is not required.\"",
"OBJECT",
"ieee8021TeipsV2TesiRowStatus",
"SYNTAX",
"RowStatus",
"{",
"active",
"(",
"1",
")",
",",
"notInService",
"(",
"2",
")",
"}",
"WRITE-SYNTAX",
"RowStatus",
"{",
"notInService",
"(",
"2",
")",
",",
"createAndGo",
"(",
"4",
")",
",",
"destroy",
"(",
"6",
")",
"}",
"DESCRIPTION",
"\"Support for createAndWait is not required.\"",
"::=",
"{",
"ieee8021TeipsV2Compliances",
"1",
"}"
],
"syntax_tree": [
[
"Status",
"current"
],
[
"DESCRIPTION",
"The compliance statement for support of the TEIPS MIB module."
],
null,
[
"ComplianceModules",
[
[
null,
[
"ieee8021TeipsV2IpgGroup",
"ieee8021TeipsV2IpgTesiGroup",
"ieee8021TeipsV2IpgConfigManGroup",
"ieee8021TeipsV2NotificationsGroup",
"ieee8021TeipsV2IpgConfigOptGroup",
"ieee8021TeipsV2CandidatePsGroup"
]
]
]
]
]
}- IEEE 802
· Publisher's source file
· Archived source file
Source location: IEEE8021-TEIPS-V2-MIB::ieee8021TeipsV2Compliance.Source version and references
Downloaded: 2026-10-19T00:20:55.106370+00:00. SHA-256:
564458c0d7d330a4bd01c9174827d6da2de0e4755b462a3e01e7f35d375f2734{'kind': 'MODULE-COMPLIANCE', 'details': {'module': 'IEEE8021-TEIPS-V2-MIB', 'imports': {'SNMPv2-TC': ['RowStatus', 'StorageType', 'TruthValue'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'NOTIFICATION-TYPE', 'OBJECT-TYPE', 'Unsigned32'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'NOTIFICATION-GROUP', 'OBJECT-GROUP'], 'IEEE8021-TC-MIB': ['ieee802dot1mibs', 'IEEE8021BridgePortNumber', 'IEEE8021TeipsIpgConfigActiveRequests', 'IEEE8021TeipsIpgid', 'IEEE8021TeipsIpgConfigAdmin', 'IEEE8021PbbTeTSidId'], 'IEEE8021-BRIDGE-MIB': ['ieee8021BridgeBaseComponentId']}, 'smi_kind': 'MODULE-COMPLIANCE', 'definition': 'ieee8021TeipsV2Compliance MODULE-COMPLIANCE\r\n STATUS current\r\n DESCRIPTION\r\n "The compliance statement for support\r\n of the TEIPS MIB module."\r\n MODULE\r\n MANDATORY-GROUPS {\r\n ieee8021TeipsV2IpgGroup,\r\n ieee8021TeipsV2IpgTesiGroup,\r\n ieee8021TeipsV2IpgConfigManGroup, \r\n ieee8021TeipsV2NotificationsGroup\r\n }\r\n GROUP ieee8021TeipsV2IpgConfigOptGroup\r\n DESCRIPTION\r\n "This group allows implmementation to\r\n optionally change the WaitToRestore,\r\n M:1 WaitToRestore, and HoldOff timers\r\n for IPGs." \r\n \r\n GROUP ieee8021TeipsV2CandidatePsGroup\r\n DESCRIPTION\r\n "This group allows implmementation to\r\n optionally list candidate Protection\r\n Segments when M:1 IPS is deployed."\r\n\r\n\r\n OBJECT ieee8021TeipsV2IpgConfigWTR\r\n MIN-ACCESS not-accessible\r\n DESCRIPTION "This object is optional."\r\n\r\n OBJECT ieee8021TeipsV2IpgConfigHoldOff\r\n MIN-ACCESS not-accessible\r\n DESCRIPTION"This object is optional." \r\n \r\n OBJECT ieee8021TeipsV2IpgConfigMWTR\r\n MIN-ACCESS not-accessible\r\n DESCRIPTION "This object is optional." \r\n\r\n OBJECT ieee8021TeipsV2IpgRowStatus\r\n SYNTAX RowStatus { active(1), notInService(2) }\r\n WRITE-SYNTAX RowStatus { notInService(2), createAndGo(4),\r\n destroy(6) }\r\n DESCRIPTION "Support for createAndWait is not required."\r\n\r\n OBJECT ieee8021TeipsV2TesiRowStatus\r\n SYNTAX RowStatus { active(1), notInService(2) }\r\n WRITE-SYNTAX RowStatus { notInService(2), createAndGo(4),\r\n destroy(6) }\r\n DESCRIPTION "Support for createAndWait is not required."\r\n\r\n ::= { ieee8021TeipsV2Compliances 1 }', 'syntax_tree': [['Status', 'current'], ['DESCRIPTION', 'The compliance statement for support of the TEIPS MIB module.'], None, ['ComplianceModules', [[None, ['ieee8021TeipsV2IpgGroup', 'ieee8021TeipsV2IpgTesiGroup', 'ieee8021TeipsV2IpgConfigManGroup', 'ieee8021TeipsV2NotificationsGroup', 'ieee8021TeipsV2IpgConfigOptGroup', 'ieee8021TeipsV2CandidatePsGroup']]]]], 'source_encoding': 'utf-8-sig'}, 'parser_version': 'mib-4'} - IEEE 802
· Publisher's source file
· Archived source file
Source location: IEEE8021-TEIPS-V2-MIB::ieee8021TeipsV2Compliance.Source version and references
Downloaded: 2026-10-19T00:20:56.098931+00:00. SHA-256:
edb495af891837d7bca70c0227c66c116e4ad485b59a4b61c24dd9ae7e86f13a{'kind': 'MODULE-COMPLIANCE', 'details': {'module': 'IEEE8021-TEIPS-V2-MIB', 'imports': {'SNMPv2-TC': ['RowStatus', 'StorageType', 'TruthValue'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'NOTIFICATION-TYPE', 'OBJECT-TYPE', 'Unsigned32'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'NOTIFICATION-GROUP', 'OBJECT-GROUP'], 'IEEE8021-TC-MIB': ['ieee802dot1mibs', 'IEEE8021BridgePortNumber', 'IEEE8021TeipsIpgConfigActiveRequests', 'IEEE8021TeipsIpgid', 'IEEE8021TeipsIpgConfigAdmin', 'IEEE8021PbbTeTSidId'], 'IEEE8021-BRIDGE-MIB': ['ieee8021BridgeBaseComponentId']}, 'smi_kind': 'MODULE-COMPLIANCE', 'definition': 'ieee8021TeipsV2Compliance MODULE-COMPLIANCE\r\n STATUS current\r\n DESCRIPTION\r\n "The compliance statement for support\r\n of the TEIPS MIB module."\r\n MODULE\r\n MANDATORY-GROUPS {\r\n ieee8021TeipsV2IpgGroup,\r\n ieee8021TeipsV2IpgTesiGroup,\r\n ieee8021TeipsV2IpgConfigManGroup, \r\n ieee8021TeipsV2NotificationsGroup\r\n }\r\n GROUP ieee8021TeipsV2IpgConfigOptGroup\r\n DESCRIPTION\r\n "This group allows implmementation to\r\n optionally change the WaitToRestore,\r\n M:1 WaitToRestore, and HoldOff timers\r\n for IPGs." \r\n \r\n GROUP ieee8021TeipsV2CandidatePsGroup\r\n DESCRIPTION\r\n "This group allows implmementation to\r\n optionally list candidate Protection\r\n Segments when M:1 IPS is deployed."\r\n\r\n\r\n OBJECT ieee8021TeipsV2IpgConfigWTR\r\n MIN-ACCESS not-accessible\r\n DESCRIPTION "This object is optional."\r\n\r\n OBJECT ieee8021TeipsV2IpgConfigHoldOff\r\n MIN-ACCESS not-accessible\r\n DESCRIPTION"This object is optional." \r\n \r\n OBJECT ieee8021TeipsV2IpgConfigMWTR\r\n MIN-ACCESS not-accessible\r\n DESCRIPTION "This object is optional." \r\n\r\n OBJECT ieee8021TeipsV2IpgRowStatus\r\n SYNTAX RowStatus { active(1), notInService(2) }\r\n WRITE-SYNTAX RowStatus { notInService(2), createAndGo(4),\r\n destroy(6) }\r\n DESCRIPTION "Support for createAndWait is not required."\r\n\r\n OBJECT ieee8021TeipsV2TesiRowStatus\r\n SYNTAX RowStatus { active(1), notInService(2) }\r\n WRITE-SYNTAX RowStatus { notInService(2), createAndGo(4),\r\n destroy(6) }\r\n DESCRIPTION "Support for createAndWait is not required."\r\n\r\n ::= { ieee8021TeipsV2Compliances 1 }', 'syntax_tree': [['Status', 'current'], ['DESCRIPTION', 'The compliance statement for support of the TEIPS MIB module.'], None, ['ComplianceModules', [[None, ['ieee8021TeipsV2IpgGroup', 'ieee8021TeipsV2IpgTesiGroup', 'ieee8021TeipsV2IpgConfigManGroup', 'ieee8021TeipsV2NotificationsGroup', 'ieee8021TeipsV2IpgConfigOptGroup', 'ieee8021TeipsV2CandidatePsGroup']]]]], 'source_encoding': 'utf-8-sig'}, 'parser_version': 'mib-4'}