Reference record for OID 1.3.111.2.802.1.1.30.1.2.1.1.12

Parent
1.3.111.2.802.1.1.30.1.2.1.1 (ieee8021STParametersEntry)
Node code
12
Node name
ieee8021STAdminCycleTimeExtension
Numeric OID
1.3.111.2.802.1.1.30.1.2.1.1.12
URN notation
urn:oid:1.3.111.2.802.1.1.30.1.2.1.1.12
ASN.1 notation

{1 3 111 2 802 1 1 30 1 2 1 1 12}

  • {iso(1) identified-organization(3) ieee(111) standards-association-numbered-series-standards(2) lan-man-stds(802) ieee802dot1(1) ieee802dot1mibs(1) ieee8021STMib(30) ieee8021STObjects(1) ieee8021STParameters(2) ieee8021STParametersTable(1) ieee8021STParametersEntry(1) ieee8021STAdminCycleTimeExtension(12)}
  • {iso(1) identified-organization(3) ieee(111) standards-association-numbers-series-standards(2) lan-man-stds(802) ieee802dot1(1) ieee802dot1mibs(1) ieee8021STMib(30) ieee8021STObjects(1) ieee8021STParameters(2) ieee8021STParametersTable(1) ieee8021STParametersEntry(1) ieee8021STAdminCycleTimeExtension(12)}
  • {iso(1) org(3) ieee(111) standards-association-numbered-series-standards(2) lan-man-stds(802) ieee802dot1(1) ieee802dot1mibs(1) ieee8021STMib(30) ieee8021STObjects(1) ieee8021STParameters(2) ieee8021STParametersTable(1) ieee8021STParametersEntry(1) ieee8021STAdminCycleTimeExtension(12)}
  • {iso(1) org(3) ieee(111) standards-association-numbers-series-standards(2) lan-man-stds(802) ieee802dot1(1) ieee802dot1mibs(1) ieee8021STMib(30) ieee8021STObjects(1) ieee8021STParameters(2) ieee8021STParametersTable(1) ieee8021STParametersEntry(1) ieee8021STAdminCycleTimeExtension(12)}
  • {iso(1) iso-identified-organization(3) ieee(111) standards-association-numbered-series-standards(2) lan-man-stds(802) ieee802dot1(1) ieee802dot1mibs(1) ieee8021STMib(30) ieee8021STObjects(1) ieee8021STParameters(2) ieee8021STParametersTable(1) ieee8021STParametersEntry(1) ieee8021STAdminCycleTimeExtension(12)}
  • {iso(1) iso-identified-organization(3) ieee(111) standards-association-numbers-series-standards(2) lan-man-stds(802) ieee802dot1(1) ieee802dot1mibs(1) ieee8021STMib(30) ieee8021STObjects(1) ieee8021STParameters(2) ieee8021STParametersTable(1) ieee8021STParametersEntry(1) ieee8021STAdminCycleTimeExtension(12)}
  • {iso(1) iso-organization(3) ieee(111) standards-association-numbered-series-standards(2) lan-man-stds(802) ieee802dot1(1) ieee802dot1mibs(1) ieee8021STMib(30) ieee8021STObjects(1) ieee8021STParameters(2) ieee8021STParametersTable(1) ieee8021STParametersEntry(1) ieee8021STAdminCycleTimeExtension(12)}
  • {iso(1) iso-organization(3) ieee(111) standards-association-numbers-series-standards(2) lan-man-stds(802) ieee802dot1(1) ieee802dot1mibs(1) ieee8021STMib(30) ieee8021STObjects(1) ieee8021STParameters(2) ieee8021STParametersTable(1) ieee8021STParametersEntry(1) ieee8021STAdminCycleTimeExtension(12)}
OID-IRI notation
  • /1/3/111/2/802/1/1/30/1/2/1/1/12
  • /ISO/Identified-Organization/111/2/802/1/1/30/1/2/1/1/12
  • /ISO/3/111/2/802/1/1/30/1/2/1/1/12
Named path variants
  • /iso/identified-organization/ieee/standards-association-numbered-series-standards/lan-man-stds/ieee802dot1/ieee802dot1mibs/ieee8021STMib/ieee8021STObjects/ieee8021STParameters/ieee8021STParametersTable/ieee8021STParametersEntry/ieee8021STAdminCycleTimeExtension
  • /iso/identified-organization/ieee/standards-association-numbers-series-standards/lan-man-stds/ieee802dot1/ieee802dot1mibs/ieee8021STMib/ieee8021STObjects/ieee8021STParameters/ieee8021STParametersTable/ieee8021STParametersEntry/ieee8021STAdminCycleTimeExtension
  • /iso/org/ieee/standards-association-numbered-series-standards/lan-man-stds/ieee802dot1/ieee802dot1mibs/ieee8021STMib/ieee8021STObjects/ieee8021STParameters/ieee8021STParametersTable/ieee8021STParametersEntry/ieee8021STAdminCycleTimeExtension
  • /iso/org/ieee/standards-association-numbers-series-standards/lan-man-stds/ieee802dot1/ieee802dot1mibs/ieee8021STMib/ieee8021STObjects/ieee8021STParameters/ieee8021STParametersTable/ieee8021STParametersEntry/ieee8021STAdminCycleTimeExtension
  • /iso/iso-identified-organization/ieee/standards-association-numbered-series-standards/lan-man-stds/ieee802dot1/ieee802dot1mibs/ieee8021STMib/ieee8021STObjects/ieee8021STParameters/ieee8021STParametersTable/ieee8021STParametersEntry/ieee8021STAdminCycleTimeExtension
  • /iso/iso-identified-organization/ieee/standards-association-numbers-series-standards/lan-man-stds/ieee802dot1/ieee802dot1mibs/ieee8021STMib/ieee8021STObjects/ieee8021STParameters/ieee8021STParametersTable/ieee8021STParametersEntry/ieee8021STAdminCycleTimeExtension
  • /iso/iso-organization/ieee/standards-association-numbered-series-standards/lan-man-stds/ieee802dot1/ieee802dot1mibs/ieee8021STMib/ieee8021STObjects/ieee8021STParameters/ieee8021STParametersTable/ieee8021STParametersEntry/ieee8021STAdminCycleTimeExtension
  • /iso/iso-organization/ieee/standards-association-numbers-series-standards/lan-man-stds/ieee802dot1/ieee802dot1mibs/ieee8021STMib/ieee8021STObjects/ieee8021STParameters/ieee8021STParametersTable/ieee8021STParametersEntry/ieee8021STAdminCycleTimeExtension

Source records

The administrative value of the CycleTimeExtension parameter for the Port. The value is an unsigned integer number of nanoseconds. The value of this object MUST be retained across reinitializations of the management system.

Status in source: current.

Names: ieee8021STAdminCycleTimeExtension

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "ieee8021STAdminCycleTimeExtension",
    "OBJECT-TYPE",
    "SYNTAX",
    "Unsigned32",
    "UNITS",
    [
      "literal",
      "226e616e6f7365636f6e647322"
    ],
    "MAX-ACCESS",
    "read-write",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"The administrative value of the CycleTimeExtension parameter for the Port. The value is an unsigned integer number of nanoseconds. The value of this object MUST be retained across reinitializations of the management system.\"",
    "REFERENCE",
    "\"8.6.8.4, 8.6.9.4, 12.29.1\"",
    "::=",
    "{",
    "ieee8021STParametersEntry",
    "12",
    "}"
  ],
  "syntax_tree": [
    [
      "ApplicationSyntax",
      "Unsigned32"
    ],
    [
      "UNITS",
      "nanoseconds"
    ],
    [
      "MaxAccessPart",
      "read-write"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "The administrative value of the CycleTimeExtension parameter for the Port. The value is an unsigned integer number of nanoseconds. The value of this object MUST be retained across reinitializations of the management system."
    ],
    [
      "REFERENCE",
      "8.6.8.4, 8.6.9.4, 12.29.1"
    ],
    null,
    null,
    null
  ]
}
  • IEEE 802 · Publisher's source file · Archived source file
    Source location: IEEE8021-ST-MIB::ieee8021STAdminCycleTimeExtension.
    Source version and references

    Downloaded: 2026-10-19T00:20:44.962101+00:00. SHA-256: 546ba8f7a3c65c40eaab34110810cfdc8176a637920225d61db7a571cc6dd462

    {'kind': 'OBJECT-TYPE', 'details': {'module': 'IEEE8021-ST-MIB', 'imports': {'SNMPv2-TC': ['TEXTUAL-CONVENTION', 'TruthValue'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Counter64'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP'], 'IEEE8021-TC-MIB': ['ieee802dot1mibs'], 'IEEE8021-BRIDGE-MIB': ['ieee8021BridgeBaseComponentId', 'ieee8021BridgeBasePort']}, 'smi_kind': 'OBJECT-TYPE', 'definition': 'ieee8021STAdminCycleTimeExtension OBJECT-TYPE\r\n    SYNTAX      Unsigned32\r\n    UNITS       "nanoseconds"\r\n    MAX-ACCESS  read-write\r\n    STATUS      current\r\n    DESCRIPTION\r\n        "The administrative value of the CycleTimeExtension \r\n        parameter for the Port. \r\n        The value is an unsigned integer number of nanoseconds.\r\n\r\n        The value of this object MUST be retained across\r\n        reinitializations of the management system."\r\n    REFERENCE   "8.6.8.4, 8.6.9.4, 12.29.1"\r\n    ::= { ieee8021STParametersEntry 12 }', 'syntax_tree': [['ApplicationSyntax', 'Unsigned32'], ['UNITS', 'nanoseconds'], ['MaxAccessPart', 'read-write'], ['Status', 'current'], ['DESCRIPTION', 'The administrative value of the CycleTimeExtension parameter for the Port. The value is an unsigned integer number of nanoseconds. The value of this object MUST be retained across reinitializations of the management system.'], ['REFERENCE', '8.6.8.4, 8.6.9.4, 12.29.1'], None, None, None], 'source_encoding': 'utf-8-sig'}, 'parser_version': 'mib-4'}
  • IEEE 802 · Publisher's source file · Archived source file
    Source location: IEEE8021-ST-MIB::ieee8021STAdminCycleTimeExtension.
    Source version and references

    Downloaded: 2026-10-19T00:20:45.905786+00:00. SHA-256: 2cc891306b0ab93d988fea358bdcda2cbf17fd4df3aacc6cb6bb87feea768164

    {'kind': 'OBJECT-TYPE', 'details': {'module': 'IEEE8021-ST-MIB', 'imports': {'SNMPv2-TC': ['TEXTUAL-CONVENTION', 'TruthValue'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Counter64'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP'], 'IEEE8021-TC-MIB': ['ieee802dot1mibs'], 'IEEE8021-BRIDGE-MIB': ['ieee8021BridgeBaseComponentId', 'ieee8021BridgeBasePort']}, 'smi_kind': 'OBJECT-TYPE', 'definition': 'ieee8021STAdminCycleTimeExtension OBJECT-TYPE\r\n    SYNTAX      Unsigned32\r\n    UNITS       "nanoseconds"\r\n    MAX-ACCESS  read-write\r\n    STATUS      current\r\n    DESCRIPTION\r\n        "The administrative value of the CycleTimeExtension \r\n        parameter for the Port. \r\n        The value is an unsigned integer number of nanoseconds.\r\n\r\n        The value of this object MUST be retained across\r\n        reinitializations of the management system."\r\n    REFERENCE   "8.6.8.4, 8.6.9.4, 12.29.1"\r\n    ::= { ieee8021STParametersEntry 12 }', 'syntax_tree': [['ApplicationSyntax', 'Unsigned32'], ['UNITS', 'nanoseconds'], ['MaxAccessPart', 'read-write'], ['Status', 'current'], ['DESCRIPTION', 'The administrative value of the CycleTimeExtension parameter for the Port. The value is an unsigned integer number of nanoseconds. The value of this object MUST be retained across reinitializations of the management system.'], ['REFERENCE', '8.6.8.4, 8.6.9.4, 12.29.1'], None, None, None], 'source_encoding': 'utf-8-sig'}, 'parser_version': 'mib-4'}
  • IEEE 802 · Publisher's source file · Archived source file
    Source location: IEEE8021-ST-MIB::ieee8021STAdminCycleTimeExtension.
    Source version and references

    Downloaded: 2026-10-19T00:21:54.316418+00:00. SHA-256: 9fb1c14e9ea8d152d08eaaaa2ab2be9f1a770defb15ecf7103c6a0cdd7afee76

    {'kind': 'OBJECT-TYPE', 'details': {'module': 'IEEE8021-ST-MIB', 'imports': {'SNMPv2-TC': ['TEXTUAL-CONVENTION', 'TruthValue'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Counter64'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP'], 'IEEE8021-TC-MIB': ['ieee802dot1mibs'], 'IEEE8021-BRIDGE-MIB': ['ieee8021BridgeBaseComponentId', 'ieee8021BridgeBasePort']}, 'smi_kind': 'OBJECT-TYPE', 'definition': 'ieee8021STAdminCycleTimeExtension OBJECT-TYPE\r\n    SYNTAX      Unsigned32\r\n    UNITS       "nanoseconds"\r\n    MAX-ACCESS  read-write\r\n    STATUS      current\r\n    DESCRIPTION\r\n        "The administrative value of the CycleTimeExtension\r\n        parameter for the Port.\r\n        The value is an unsigned integer number of nanoseconds.\r\n\r\n        The value of this object MUST be retained across\r\n        reinitializations of the management system."\r\n    REFERENCE   "8.6.8.4, 8.6.9.4, 12.29.1"\r\n    ::= { ieee8021STParametersEntry 12 }', 'syntax_tree': [['ApplicationSyntax', 'Unsigned32'], ['UNITS', 'nanoseconds'], ['MaxAccessPart', 'read-write'], ['Status', 'current'], ['DESCRIPTION', 'The administrative value of the CycleTimeExtension parameter for the Port. The value is an unsigned integer number of nanoseconds. The value of this object MUST be retained across reinitializations of the management system.'], ['REFERENCE', '8.6.8.4, 8.6.9.4, 12.29.1'], None, None, None], 'source_encoding': 'utf-8-sig'}, 'parser_version': 'mib-4'}
  • IEEE 802 · Publisher's source file · Archived source file
    Source location: IEEE8021-ST-MIB::ieee8021STAdminCycleTimeExtension.
    Source version and references

    Downloaded: 2026-10-19T00:21:55.022169+00:00. SHA-256: dc0c3c024e96a095b7a17939348a057725e7303272192886e9487821248483a0

    {'kind': 'OBJECT-TYPE', 'details': {'module': 'IEEE8021-ST-MIB', 'imports': {'SNMPv2-TC': ['TEXTUAL-CONVENTION', 'TruthValue'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Counter64'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP'], 'IEEE8021-TC-MIB': ['ieee802dot1mibs'], 'IEEE8021-BRIDGE-MIB': ['ieee8021BridgeBaseComponentId', 'ieee8021BridgeBasePort']}, 'smi_kind': 'OBJECT-TYPE', 'definition': 'ieee8021STAdminCycleTimeExtension OBJECT-TYPE\n    SYNTAX      Unsigned32\n    UNITS       "nanoseconds"\n    MAX-ACCESS  read-write\n    STATUS      current\n    DESCRIPTION\n        "The administrative value of the CycleTimeExtension \n        parameter for the Port. \n        The value is an unsigned integer number of nanoseconds.\n\n        The value of this object MUST be retained across\n        reinitializations of the management system."\n    REFERENCE   "8.6.8.4, 8.6.9.4, 12.29.1"\n    ::= { ieee8021STParametersEntry 12 }', 'syntax_tree': [['ApplicationSyntax', 'Unsigned32'], ['UNITS', 'nanoseconds'], ['MaxAccessPart', 'read-write'], ['Status', 'current'], ['DESCRIPTION', 'The administrative value of the CycleTimeExtension parameter for the Port. The value is an unsigned integer number of nanoseconds. The value of this object MUST be retained across reinitializations of the management system.'], ['REFERENCE', '8.6.8.4, 8.6.9.4, 12.29.1'], None, None, None], 'source_encoding': 'utf-8-sig'}, 'parser_version': 'mib-4'}
  • IEEE 802 · Publisher's source file · Archived source file
    Source location: IEEE8021-ST-MIB::ieee8021STAdminCycleTimeExtension.
    Source version and references

    Downloaded: 2026-10-19T00:21:55.720364+00:00. SHA-256: 1bfb58eb74a8040f08dbcfcbba5630e1f574dc18a5d5f12f716e4d5b849c92e6

    {'kind': 'OBJECT-TYPE', 'details': {'module': 'IEEE8021-ST-MIB', 'imports': {'SNMPv2-TC': ['TEXTUAL-CONVENTION', 'TruthValue'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Counter64'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP'], 'IEEE8021-TC-MIB': ['ieee802dot1mibs'], 'IEEE8021-BRIDGE-MIB': ['ieee8021BridgeBaseComponentId', 'ieee8021BridgeBasePort']}, 'smi_kind': 'OBJECT-TYPE', 'definition': 'ieee8021STAdminCycleTimeExtension OBJECT-TYPE\r\n    SYNTAX      Unsigned32\r\n    UNITS       "nanoseconds"\r\n    MAX-ACCESS  read-write\r\n    STATUS      current\r\n    DESCRIPTION\r\n        "The administrative value of the CycleTimeExtension \r\n        parameter for the Port. \r\n        The value is an unsigned integer number of nanoseconds.\r\n\r\n        The value of this object MUST be retained across\r\n        reinitializations of the management system."\r\n    REFERENCE   "8.6.8.4, 8.6.9.4, 12.29.1"\r\n    ::= { ieee8021STParametersEntry 12 }', 'syntax_tree': [['ApplicationSyntax', 'Unsigned32'], ['UNITS', 'nanoseconds'], ['MaxAccessPart', 'read-write'], ['Status', 'current'], ['DESCRIPTION', 'The administrative value of the CycleTimeExtension parameter for the Port. The value is an unsigned integer number of nanoseconds. The value of this object MUST be retained across reinitializations of the management system.'], ['REFERENCE', '8.6.8.4, 8.6.9.4, 12.29.1'], None, None, None], 'source_encoding': 'utf-8-sig'}, 'parser_version': 'mib-4'}

Current Registration Authority (inferred from ancestor 1.3)

Frank Farance

Siblings (24)

OIDNameDirect childrenDescendantsDescription
1.3.111.2.802.1.1.30.1.2.1.1.1 ieee8021STGateEnabled00
1.3.111.2.802.1.1.30.1.2.1.1.2 ieee8021STAdminGateStates00
1.3.111.2.802.1.1.30.1.2.1.1.3 ieee8021STOperGateStates00
1.3.111.2.802.1.1.30.1.2.1.1.4 ieee8021STAdminControlListLength00
1.3.111.2.802.1.1.30.1.2.1.1.5 ieee8021STOperControlListLength00
1.3.111.2.802.1.1.30.1.2.1.1.6 ieee8021STAdminControlList00
1.3.111.2.802.1.1.30.1.2.1.1.7 ieee8021STOperControlList00
1.3.111.2.802.1.1.30.1.2.1.1.8 ieee8021STAdminCycleTimeNumerator00
1.3.111.2.802.1.1.30.1.2.1.1.9 ieee8021STAdminCycleTimeDenominator00
1.3.111.2.802.1.1.30.1.2.1.1.10 ieee8021STOperCycleTimeNumerator00
1.3.111.2.802.1.1.30.1.2.1.1.11 ieee8021STOperCycleTimeDenominator00
1.3.111.2.802.1.1.30.1.2.1.1.13 ieee8021STOperCycleTimeExtension00
1.3.111.2.802.1.1.30.1.2.1.1.14 ieee8021STAdminBaseTime00
1.3.111.2.802.1.1.30.1.2.1.1.15 ieee8021STOperBaseTime00
1.3.111.2.802.1.1.30.1.2.1.1.16 ieee8021STConfigChange00
1.3.111.2.802.1.1.30.1.2.1.1.17 ieee8021STConfigChangeTime00
1.3.111.2.802.1.1.30.1.2.1.1.18 ieee8021STTickGranularity00
1.3.111.2.802.1.1.30.1.2.1.1.19 ieee8021STCurrentTime00
1.3.111.2.802.1.1.30.1.2.1.1.20 ieee8021STConfigPending00
1.3.111.2.802.1.1.30.1.2.1.1.21 ieee8021STConfigChangeError00
1.3.111.2.802.1.1.30.1.2.1.1.22 ieee8021STSupportedListMax00
1.3.111.2.802.1.1.30.1.2.1.1.23 ieee8021STSupportedCycleMaxNumerator00
1.3.111.2.802.1.1.30.1.2.1.1.24 ieee8021STSupportedCycleMaxDenominator00
1.3.111.2.802.1.1.30.1.2.1.1.25 ieee8021STSupportedIntervalMax00