Reference record for OID 1.3.111.2.802.1.1.33.1.1.1.3

Parent
1.3.111.2.802.1.1.33.1.1.1 (ieee8021AsV2PtpInstanceEntry)
Node code
3
Node name
ieee8021AsV2PtpInstanceRowStatus
Numeric OID
1.3.111.2.802.1.1.33.1.1.1.3
URN notation
urn:oid:1.3.111.2.802.1.1.33.1.1.1.3
ASN.1 notation

{1 3 111 2 802 1 1 33 1 1 1 3}

  • {iso(1) identified-organization(3) ieee(111) standards-association-numbered-series-standards(2) lan-man-stds(802) ieee802dot1(1) ieee802dot1mibs(1) ieee8021AsV2TimeSyncMib(33) ieee8021AsV2MIBObjects(1) ieee8021AsV2PtpInstanceTable(1) ieee8021AsV2PtpInstanceEntry(1) ieee8021AsV2PtpInstanceRowStatus(3)}
  • {iso(1) identified-organization(3) ieee(111) standards-association-numbers-series-standards(2) lan-man-stds(802) ieee802dot1(1) ieee802dot1mibs(1) ieee8021AsV2TimeSyncMib(33) ieee8021AsV2MIBObjects(1) ieee8021AsV2PtpInstanceTable(1) ieee8021AsV2PtpInstanceEntry(1) ieee8021AsV2PtpInstanceRowStatus(3)}
  • {iso(1) org(3) ieee(111) standards-association-numbered-series-standards(2) lan-man-stds(802) ieee802dot1(1) ieee802dot1mibs(1) ieee8021AsV2TimeSyncMib(33) ieee8021AsV2MIBObjects(1) ieee8021AsV2PtpInstanceTable(1) ieee8021AsV2PtpInstanceEntry(1) ieee8021AsV2PtpInstanceRowStatus(3)}
  • {iso(1) org(3) ieee(111) standards-association-numbers-series-standards(2) lan-man-stds(802) ieee802dot1(1) ieee802dot1mibs(1) ieee8021AsV2TimeSyncMib(33) ieee8021AsV2MIBObjects(1) ieee8021AsV2PtpInstanceTable(1) ieee8021AsV2PtpInstanceEntry(1) ieee8021AsV2PtpInstanceRowStatus(3)}
  • {iso(1) iso-identified-organization(3) ieee(111) standards-association-numbered-series-standards(2) lan-man-stds(802) ieee802dot1(1) ieee802dot1mibs(1) ieee8021AsV2TimeSyncMib(33) ieee8021AsV2MIBObjects(1) ieee8021AsV2PtpInstanceTable(1) ieee8021AsV2PtpInstanceEntry(1) ieee8021AsV2PtpInstanceRowStatus(3)}
  • {iso(1) iso-identified-organization(3) ieee(111) standards-association-numbers-series-standards(2) lan-man-stds(802) ieee802dot1(1) ieee802dot1mibs(1) ieee8021AsV2TimeSyncMib(33) ieee8021AsV2MIBObjects(1) ieee8021AsV2PtpInstanceTable(1) ieee8021AsV2PtpInstanceEntry(1) ieee8021AsV2PtpInstanceRowStatus(3)}
  • {iso(1) iso-organization(3) ieee(111) standards-association-numbered-series-standards(2) lan-man-stds(802) ieee802dot1(1) ieee802dot1mibs(1) ieee8021AsV2TimeSyncMib(33) ieee8021AsV2MIBObjects(1) ieee8021AsV2PtpInstanceTable(1) ieee8021AsV2PtpInstanceEntry(1) ieee8021AsV2PtpInstanceRowStatus(3)}
  • {iso(1) iso-organization(3) ieee(111) standards-association-numbers-series-standards(2) lan-man-stds(802) ieee802dot1(1) ieee802dot1mibs(1) ieee8021AsV2TimeSyncMib(33) ieee8021AsV2MIBObjects(1) ieee8021AsV2PtpInstanceTable(1) ieee8021AsV2PtpInstanceEntry(1) ieee8021AsV2PtpInstanceRowStatus(3)}
OID-IRI notation
  • /1/3/111/2/802/1/1/33/1/1/1/3
  • /ISO/Identified-Organization/111/2/802/1/1/33/1/1/1/3
  • /ISO/3/111/2/802/1/1/33/1/1/1/3
Named path variants
  • /iso/identified-organization/ieee/standards-association-numbered-series-standards/lan-man-stds/ieee802dot1/ieee802dot1mibs/ieee8021AsV2TimeSyncMib/ieee8021AsV2MIBObjects/ieee8021AsV2PtpInstanceTable/ieee8021AsV2PtpInstanceEntry/ieee8021AsV2PtpInstanceRowStatus
  • /iso/identified-organization/ieee/standards-association-numbers-series-standards/lan-man-stds/ieee802dot1/ieee802dot1mibs/ieee8021AsV2TimeSyncMib/ieee8021AsV2MIBObjects/ieee8021AsV2PtpInstanceTable/ieee8021AsV2PtpInstanceEntry/ieee8021AsV2PtpInstanceRowStatus
  • /iso/org/ieee/standards-association-numbered-series-standards/lan-man-stds/ieee802dot1/ieee802dot1mibs/ieee8021AsV2TimeSyncMib/ieee8021AsV2MIBObjects/ieee8021AsV2PtpInstanceTable/ieee8021AsV2PtpInstanceEntry/ieee8021AsV2PtpInstanceRowStatus
  • /iso/org/ieee/standards-association-numbers-series-standards/lan-man-stds/ieee802dot1/ieee802dot1mibs/ieee8021AsV2TimeSyncMib/ieee8021AsV2MIBObjects/ieee8021AsV2PtpInstanceTable/ieee8021AsV2PtpInstanceEntry/ieee8021AsV2PtpInstanceRowStatus
  • /iso/iso-identified-organization/ieee/standards-association-numbered-series-standards/lan-man-stds/ieee802dot1/ieee802dot1mibs/ieee8021AsV2TimeSyncMib/ieee8021AsV2MIBObjects/ieee8021AsV2PtpInstanceTable/ieee8021AsV2PtpInstanceEntry/ieee8021AsV2PtpInstanceRowStatus
  • /iso/iso-identified-organization/ieee/standards-association-numbers-series-standards/lan-man-stds/ieee802dot1/ieee802dot1mibs/ieee8021AsV2TimeSyncMib/ieee8021AsV2MIBObjects/ieee8021AsV2PtpInstanceTable/ieee8021AsV2PtpInstanceEntry/ieee8021AsV2PtpInstanceRowStatus
  • /iso/iso-organization/ieee/standards-association-numbered-series-standards/lan-man-stds/ieee802dot1/ieee802dot1mibs/ieee8021AsV2TimeSyncMib/ieee8021AsV2MIBObjects/ieee8021AsV2PtpInstanceTable/ieee8021AsV2PtpInstanceEntry/ieee8021AsV2PtpInstanceRowStatus
  • /iso/iso-organization/ieee/standards-association-numbers-series-standards/lan-man-stds/ieee802dot1/ieee802dot1mibs/ieee8021AsV2TimeSyncMib/ieee8021AsV2MIBObjects/ieee8021AsV2PtpInstanceTable/ieee8021AsV2PtpInstanceEntry/ieee8021AsV2PtpInstanceRowStatus

Source records

This attribute is used to create and delete PTP Instances.

Status in source: current.

Names: ieee8021AsV2PtpInstanceRowStatus

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "ieee8021AsV2PtpInstanceRowStatus",
    "OBJECT-TYPE",
    "SYNTAX",
    "RowStatus",
    "MAX-ACCESS",
    "read-create",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"This attribute is used to create and delete PTP Instances.\"",
    "REFERENCE",
    "\"14.1\"",
    "::=",
    "{",
    "ieee8021AsV2PtpInstanceEntry",
    "3",
    "}"
  ],
  "syntax_tree": [
    [
      "row",
      "RowStatus"
    ],
    null,
    [
      "MaxAccessPart",
      "read-create"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "This attribute is used to create and delete PTP Instances."
    ],
    [
      "REFERENCE",
      "14.1"
    ],
    null,
    null,
    null
  ]
}
  • IEEE 802 · Publisher's source file · Archived source file
    Source location: IEEE8021-AS-V2-MIB::ieee8021AsV2PtpInstanceRowStatus.
    Source version and references

    Downloaded: 2026-10-19T00:19:20.152770+00:00. SHA-256: 50461952eabe10247431628591c194ab360a1b909071c39330056d7a87810171

    {'kind': 'OBJECT-TYPE', 'details': {'module': 'IEEE8021-AS-V2-MIB', 'imports': {'IF-MIB': ['InterfaceIndexOrZero'], 'SNMPv2-TC': ['TEXTUAL-CONVENTION', 'TruthValue', 'RowStatus', 'TimeStamp'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Integer32', 'Counter32'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP'], 'FLOAT-TC-MIB': ['Float64TC'], 'IEEE8021-TC-MIB': ['IEEE8021BridgePortNumber'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}, 'smi_kind': 'OBJECT-TYPE', 'definition': 'ieee8021AsV2PtpInstanceRowStatus OBJECT-TYPE\r\n    SYNTAX RowStatus\r\n    MAX-ACCESS read-create\r\n    STATUS current\r\n    DESCRIPTION\r\n        "This attribute is used to create and delete PTP Instances."\r\n    REFERENCE "14.1"\r\n    ::= { ieee8021AsV2PtpInstanceEntry 3 }', 'syntax_tree': [['row', 'RowStatus'], None, ['MaxAccessPart', 'read-create'], ['Status', 'current'], ['DESCRIPTION', 'This attribute is used to create and delete PTP Instances.'], ['REFERENCE', '14.1'], None, None, None], 'source_encoding': 'utf-8-sig'}, 'parser_version': 'mib-4'}