The managed object is a Boolean that determines the source of currentOneStepTxOper. If the value is TRUE (1), the value of currentOneStepTxOper is set equal to the value of mgtSettableOneStepTxOper. If the value is FALSE (2), the value of currentOneStepTxOper is determined by the OneStepTxOperSetting state machine. The default value of useMgtSettableOneStepTxOper is TRUE (1).
Status in source: current.
Names: ieee8021AsV2PortDSUseMgtSettableOneStepTxOper
Technical details
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"ieee8021AsV2PortDSUseMgtSettableOneStepTxOper",
"OBJECT-TYPE",
"SYNTAX",
"TruthValue",
"MAX-ACCESS",
"read-write",
"STATUS",
"current",
"DESCRIPTION",
"\"The managed object is a Boolean that determines the source of currentOneStepTxOper. If the value is TRUE (1), the value of currentOneStepTxOper is set equal to the value of mgtSettableOneStepTxOper. If the value is FALSE (2), the value of currentOneStepTxOper is determined by the OneStepTxOperSetting state machine. The default value of useMgtSettableOneStepTxOper is TRUE (1).\"",
"REFERENCE",
"\"14.8.50\"",
"DEFVAL",
"{",
"true",
"}",
"::=",
"{",
"ieee8021AsV2PortDSEntry",
"52",
"}"
],
"syntax_tree": [
[
"row",
"TruthValue"
],
null,
[
"MaxAccessPart",
"read-write"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"The managed object is a Boolean that determines the source of currentOneStepTxOper. If the value is TRUE (1), the value of currentOneStepTxOper is set equal to the value of mgtSettableOneStepTxOper. If the value is FALSE (2), the value of currentOneStepTxOper is determined by the OneStepTxOperSetting state machine. The default value of useMgtSettableOneStepTxOper is TRUE (1)."
],
[
"REFERENCE",
"14.8.50"
],
null,
null,
[
"DEFVAL",
"true"
]
]
}- IEEE 802
· Publisher's source file
· Archived source file
Source location: IEEE8021-AS-V2-MIB::ieee8021AsV2PortDSUseMgtSettableOneStepTxOper.Source version and references
Downloaded: 2026-10-19T00:19:20.152770+00:00. SHA-256:
50461952eabe10247431628591c194ab360a1b909071c39330056d7a87810171{'kind': 'OBJECT-TYPE', 'details': {'module': 'IEEE8021-AS-V2-MIB', 'imports': {'IF-MIB': ['InterfaceIndexOrZero'], 'SNMPv2-TC': ['TEXTUAL-CONVENTION', 'TruthValue', 'RowStatus', 'TimeStamp'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Integer32', 'Counter32'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP'], 'FLOAT-TC-MIB': ['Float64TC'], 'IEEE8021-TC-MIB': ['IEEE8021BridgePortNumber'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}, 'smi_kind': 'OBJECT-TYPE', 'definition': 'ieee8021AsV2PortDSUseMgtSettableOneStepTxOper OBJECT-TYPE\r\n SYNTAX TruthValue\r\n MAX-ACCESS read-write\r\n STATUS current\r\n DESCRIPTION\r\n "The managed object is a Boolean that determines the source\r\n of currentOneStepTxOper. If the value is TRUE (1), the\r\n value of currentOneStepTxOper is set equal to the value of\r\n mgtSettableOneStepTxOper. If the value is FALSE (2), the\r\n value of currentOneStepTxOper is determined by the\r\n OneStepTxOperSetting state machine.\r\n The default value of useMgtSettableOneStepTxOper is TRUE (1)."\r\n REFERENCE "14.8.50"\r\n DEFVAL { true }\r\n ::= { ieee8021AsV2PortDSEntry 52 }', 'syntax_tree': [['row', 'TruthValue'], None, ['MaxAccessPart', 'read-write'], ['Status', 'current'], ['DESCRIPTION', 'The managed object is a Boolean that determines the source of currentOneStepTxOper. If the value is TRUE (1), the value of currentOneStepTxOper is set equal to the value of mgtSettableOneStepTxOper. If the value is FALSE (2), the value of currentOneStepTxOper is determined by the OneStepTxOperSetting state machine. The default value of useMgtSettableOneStepTxOper is TRUE (1).'], ['REFERENCE', '14.8.50'], None, None, ['DEFVAL', 'true']], 'source_encoding': 'utf-8-sig'}, 'parser_version': 'mib-4'}