The value is equal to the value of the Boolean asymmetryMeasurementMode(see G.3). For full-duplex IEEE 802.3 media, the value is TRUE (1) if an asymmetry measurement is being performed for the link attached to this Link Port, and FALSE (2) otherwise. For all other media, the value shall be FALSE (2) (see 10.2.4.2). Setting this managed object causes the Boolean allowedFaults to have the same value. NOTE: If an asymmetry measurement is being performed for a link, asymmetryMeasurementMode must be TRUE (1) for the Link Ports at each end of the link. There is one Common Mean Link Delay Service Asymmetry Measurement Mode Parameter Data Set Table for all PTP Instances, per Link Port.
Status in source: current.
Names: ieee8021AsV2CmldsAsymMeasurementModeDSAsymMeasurementMode
Technical details
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"ieee8021AsV2CmldsAsymMeasurementModeDSAsymMeasurementMode",
"OBJECT-TYPE",
"SYNTAX",
"TruthValue",
"MAX-ACCESS",
"read-write",
"STATUS",
"current",
"DESCRIPTION",
"\"The value is equal to the value of the Boolean asymmetryMeasurementMode(see G.3). For full-duplex IEEE 802.3 media, the value is TRUE (1) if an asymmetry measurement is being performed for the link attached to this Link Port, and FALSE (2) otherwise. For all other media, the value shall be FALSE (2) (see 10.2.4.2). Setting this managed object causes the Boolean allowedFaults to have the same value. NOTE: If an asymmetry measurement is being performed for a link, asymmetryMeasurementMode must be TRUE (1) for the Link Ports at each end of the link. There is one Common Mean Link Delay Service Asymmetry Measurement Mode Parameter Data Set Table for all PTP Instances, per Link Port.\"",
"REFERENCE",
"\"14.18.2\"",
"::=",
"{",
"ieee8021AsV2CommonMeanLinkDelayServiceAsymMeasurementModeDSEntry",
"2",
"}"
],
"syntax_tree": [
[
"row",
"TruthValue"
],
null,
[
"MaxAccessPart",
"read-write"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"The value is equal to the value of the Boolean asymmetryMeasurementMode(see G.3). For full-duplex IEEE 802.3 media, the value is TRUE (1) if an asymmetry measurement is being performed for the link attached to this Link Port, and FALSE (2) otherwise. For all other media, the value shall be FALSE (2) (see 10.2.4.2). Setting this managed object causes the Boolean allowedFaults to have the same value. NOTE: If an asymmetry measurement is being performed for a link, asymmetryMeasurementMode must be TRUE (1) for the Link Ports at each end of the link. There is one Common Mean Link Delay Service Asymmetry Measurement Mode Parameter Data Set Table for all PTP Instances, per Link Port."
],
[
"REFERENCE",
"14.18.2"
],
null,
null,
null
]
}- IEEE 802
· Publisher's source file
· Archived source file
Source location: IEEE8021-AS-V2-MIB::ieee8021AsV2CmldsAsymMeasurementModeDSAsymMeasurementMode.Source version and references
Downloaded: 2026-10-19T00:19:20.152770+00:00. SHA-256:
50461952eabe10247431628591c194ab360a1b909071c39330056d7a87810171{'kind': 'OBJECT-TYPE', 'details': {'module': 'IEEE8021-AS-V2-MIB', 'imports': {'IF-MIB': ['InterfaceIndexOrZero'], 'SNMPv2-TC': ['TEXTUAL-CONVENTION', 'TruthValue', 'RowStatus', 'TimeStamp'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Integer32', 'Counter32'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP'], 'FLOAT-TC-MIB': ['Float64TC'], 'IEEE8021-TC-MIB': ['IEEE8021BridgePortNumber'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}, 'smi_kind': 'OBJECT-TYPE', 'definition': 'ieee8021AsV2CmldsAsymMeasurementModeDSAsymMeasurementMode\r\n OBJECT-TYPE\r\n SYNTAX TruthValue\r\n MAX-ACCESS read-write\r\n STATUS current\r\n DESCRIPTION\r\n "The value is equal to the value of the Boolean\r\n asymmetryMeasurementMode(see G.3). For full-duplex\r\n IEEE 802.3 media, the value is TRUE (1) if an asymmetry\r\n measurement is being performed for the link attached to\r\n this Link Port, and FALSE (2) otherwise. For all other\r\n media, the value shall be FALSE (2) (see 10.2.4.2).\r\n Setting this managed object causes the Boolean\r\n allowedFaults to have the same value.\r\n NOTE: If an asymmetry measurement is being performed\r\n for a link, asymmetryMeasurementMode must be TRUE (1)\r\n for the Link Ports at each end of the link.\r\n There is one Common Mean Link Delay Service Asymmetry\r\n Measurement Mode Parameter Data Set Table for all PTP\r\n Instances, per Link Port."\r\n REFERENCE "14.18.2"\r\n ::= { ieee8021AsV2CommonMeanLinkDelayServiceAsymMeasurementModeDSEntry 2 }', 'syntax_tree': [['row', 'TruthValue'], None, ['MaxAccessPart', 'read-write'], ['Status', 'current'], ['DESCRIPTION', 'The value is equal to the value of the Boolean asymmetryMeasurementMode(see G.3). For full-duplex IEEE 802.3 media, the value is TRUE (1) if an asymmetry measurement is being performed for the link attached to this Link Port, and FALSE (2) otherwise. For all other media, the value shall be FALSE (2) (see 10.2.4.2). Setting this managed object causes the Boolean allowedFaults to have the same value. NOTE: If an asymmetry measurement is being performed for a link, asymmetryMeasurementMode must be TRUE (1) for the Link Ports at each end of the link. There is one Common Mean Link Delay Service Asymmetry Measurement Mode Parameter Data Set Table for all PTP Instances, per Link Port.'], ['REFERENCE', '14.18.2'], None, None, None], 'source_encoding': 'utf-8-sig'}, 'parser_version': 'mib-4'}