An integer specifying a path or LAN. If and only if a packet matches an entry in the Sequence identification table that specifies HSR or PRP in its frerSeqEncEncapsType object, tsnStreamIdLanPathId specifies the LanId or PathId value that must be matched for this tsnStreamIdEntry to apply. A value of -1 indicates that the LanId or PathId are to be ignored.
Status in source: current.
Names: ieee8021StreamIdLanPathId
Technical details
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"ieee8021StreamIdLanPathId",
"OBJECT-TYPE",
"SYNTAX",
"Ieee8021CBLanPathIdType",
"MAX-ACCESS",
"read-only",
"STATUS",
"current",
"DESCRIPTION",
"\"An integer specifying a path or LAN. If and only if a packet matches an entry in the Sequence identification table that specifies HSR or PRP in its frerSeqEncEncapsType object, tsnStreamIdLanPathId specifies the LanId or PathId value that must be matched for this tsnStreamIdEntry to apply. A value of -1 indicates that the LanId or PathId are to be ignored.\"",
"REFERENCE",
"\"10.2.2\"",
"::=",
"{",
"ieee8021StreamIdStreamIdentificationEntry",
"13",
"}"
],
"syntax_tree": [
[
"row",
"Ieee8021CBLanPathIdType"
],
null,
[
"MaxAccessPart",
"read-only"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"An integer specifying a path or LAN. If and only if a packet matches an entry in the Sequence identification table that specifies HSR or PRP in its frerSeqEncEncapsType object, tsnStreamIdLanPathId specifies the LanId or PathId value that must be matched for this tsnStreamIdEntry to apply. A value of -1 indicates that the LanId or PathId are to be ignored."
],
[
"REFERENCE",
"10.2.2"
],
null,
null,
null
]
}- IEEE 802
· Publisher's source file
· Archived source file
Source location: IEEE8021-STREAM-IDENTIFICATION-MIB::ieee8021StreamIdLanPathId.Source version and references
Downloaded: 2026-10-19T00:21:56.819067+00:00. SHA-256:
6ddda9fa1086bce6167d0092382b77216ce256548f1c8410b3c16350181a8934{'kind': 'OBJECT-TYPE', 'details': {'module': 'IEEE8021-STREAM-IDENTIFICATION-MIB', 'imports': {'IF-MIB': ['ifIndex'], 'SNMPv2-TC': ['TEXTUAL-CONVENTION', 'TruthValue', 'RowStatus', 'MacAddress', 'AutonomousType', 'VariablePointer'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'OBJECT-IDENTITY', 'Counter64', 'Unsigned32', 'Integer32'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE'], 'IEEE8021-TC-MIB': ['IEEE8021PriorityValue', 'ieee802dot1mibs'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress', 'InetPortNumber']}, 'smi_kind': 'OBJECT-TYPE', 'definition': 'ieee8021StreamIdLanPathId OBJECT-TYPE\n SYNTAX Ieee8021CBLanPathIdType\n MAX-ACCESS read-only\n STATUS current\n DESCRIPTION\n "An integer specifying a path or LAN. If and only if a packet\n matches an entry in the Sequence identification table that\n specifies HSR or PRP in its frerSeqEncEncapsType object,\n tsnStreamIdLanPathId specifies the LanId or PathId value that\n must be matched for this tsnStreamIdEntry to apply. A value\n of -1 indicates that the LanId or PathId are to be ignored."\n REFERENCE "10.2.2"\n ::= { ieee8021StreamIdStreamIdentificationEntry 13 }', 'syntax_tree': [['row', 'Ieee8021CBLanPathIdType'], None, ['MaxAccessPart', 'read-only'], ['Status', 'current'], ['DESCRIPTION', 'An integer specifying a path or LAN. If and only if a packet matches an entry in the Sequence identification table that specifies HSR or PRP in its frerSeqEncEncapsType object, tsnStreamIdLanPathId specifies the LanId or PathId value that must be matched for this tsnStreamIdEntry to apply. A value of -1 indicates that the LanId or PathId are to be ignored.'], ['REFERENCE', '10.2.2'], None, None, None], 'source_encoding': 'utf-8-sig'}, 'parser_version': 'mib-4'} - IEEE 802
· Publisher's source file
· Archived source file
Source location: IEEE8021-STREAM-IDENTIFICATION-MIB::ieee8021StreamIdLanPathId.Source version and references
Downloaded: 2026-10-19T00:21:58.118603+00:00. SHA-256:
0e477a373a5e10ff70660027eed6eaf438e45e64d66da3080630d22072f508fa{'kind': 'OBJECT-TYPE', 'details': {'module': 'IEEE8021-STREAM-IDENTIFICATION-MIB', 'imports': {'IF-MIB': ['ifIndex'], 'SNMPv2-TC': ['TEXTUAL-CONVENTION', 'TruthValue', 'RowStatus', 'MacAddress', 'AutonomousType', 'VariablePointer'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'OBJECT-IDENTITY', 'Counter64', 'Unsigned32', 'Integer32'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE'], 'IEEE8021-TC-MIB': ['IEEE8021PriorityValue', 'ieee802dot1mibs'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress', 'InetPortNumber']}, 'smi_kind': 'OBJECT-TYPE', 'definition': 'ieee8021StreamIdLanPathId OBJECT-TYPE\n SYNTAX Ieee8021CBLanPathIdType\n MAX-ACCESS read-only\n STATUS current\n DESCRIPTION\n "An integer specifying a path or LAN. If and only if a packet\n matches an entry in the Sequence identification table that\n specifies HSR or PRP in its frerSeqEncEncapsType object,\n tsnStreamIdLanPathId specifies the LanId or PathId value that\n must be matched for this tsnStreamIdEntry to apply. A value\n of -1 indicates that the LanId or PathId are to be ignored."\n REFERENCE "10.2.2"\n ::= { ieee8021StreamIdStreamIdentificationEntry 13 }', 'syntax_tree': [['row', 'Ieee8021CBLanPathIdType'], None, ['MaxAccessPart', 'read-only'], ['Status', 'current'], ['DESCRIPTION', 'An integer specifying a path or LAN. If and only if a packet matches an entry in the Sequence identification table that specifies HSR or PRP in its frerSeqEncEncapsType object, tsnStreamIdLanPathId specifies the LanId or PathId value that must be matched for this tsnStreamIdEntry to apply. A value of -1 indicates that the LanId or PathId are to be ignored.'], ['REFERENCE', '10.2.2'], None, None, None], 'source_encoding': 'utf-8-sig'}, 'parser_version': 'mib-4'}