This managed object indicates that the Sequence generation function is to be reset by calling its corresponding SequenceGenerationReset function. Writing the value True to this managed object triggers a reset; writing the value False has no effect. When read, this managed object always returns the value False.
Status in source: current.
Names: ieee8021FrerSequenceGenerationReset
Technical details
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"ieee8021FrerSequenceGenerationReset",
"OBJECT-TYPE",
"SYNTAX",
"TruthValue",
"MAX-ACCESS",
"read-write",
"STATUS",
"current",
"DESCRIPTION",
"\"This managed object indicates that the Sequence generation function is to be reset by calling its corresponding SequenceGenerationReset function. Writing the value True to this managed object triggers a reset; writing the value False has no effect. When read, this managed object always returns the value False.\"",
"REFERENCE",
"\"10.3.1.3\"",
"::=",
"{",
"ieee8021FrerSequenceGenerationEntry",
"4",
"}"
],
"syntax_tree": [
[
"row",
"TruthValue"
],
null,
[
"MaxAccessPart",
"read-write"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"This managed object indicates that the Sequence generation function is to be reset by calling its corresponding SequenceGenerationReset function. Writing the value True to this managed object triggers a reset; writing the value False has no effect. When read, this managed object always returns the value False."
],
[
"REFERENCE",
"10.3.1.3"
],
null,
null,
null
]
}- IEEE 802
· Publisher's source file
· Archived source file
Source location: IEEE8021-FRER-MIB::ieee8021FrerSequenceGenerationReset.Source version and references
Downloaded: 2026-10-19T00:21:33.985475+00:00. SHA-256:
49835dfa7b21b0f0c35727922c63900636f0a07fd00cced17f9ec356e42bf30f{'kind': 'OBJECT-TYPE', 'details': {'module': 'IEEE8021-FRER-MIB', 'imports': {'IF-MIB': ['ifIndex', 'InterfaceIndex'], 'SNMPv2-TC': ['TEXTUAL-CONVENTION', 'TruthValue', 'RowStatus', 'AutonomousType', 'VariablePointer'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Counter64', 'Unsigned32', 'Integer32'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE'], 'IEEE8021-TC-MIB': ['ieee802dot1mibs'], 'IEEE8021-STREAM-IDENTIFICATION-MIB': ['Ieee8021CBTaggedType', 'Ieee8021CBVlanIdentifier', 'Ieee8021CBLanPathIdType', 'ieee8021StreamIdStreamIdHandle']}, 'smi_kind': 'OBJECT-TYPE', 'definition': 'ieee8021FrerSequenceGenerationReset OBJECT-TYPE\n SYNTAX TruthValue\n MAX-ACCESS read-write\n STATUS current\n DESCRIPTION\n "This managed object indicates that the Sequence generation\n function is to be reset by calling its corresponding\n SequenceGenerationReset function. Writing the value True to\n this managed object triggers a reset; writing the value False\n has no effect. When read, this managed object always returns\n the value False."\n REFERENCE "10.3.1.3"\n ::= { ieee8021FrerSequenceGenerationEntry 4 }', 'syntax_tree': [['row', 'TruthValue'], None, ['MaxAccessPart', 'read-write'], ['Status', 'current'], ['DESCRIPTION', 'This managed object indicates that the Sequence generation function is to be reset by calling its corresponding SequenceGenerationReset function. Writing the value True to this managed object triggers a reset; writing the value False has no effect. When read, this managed object always returns the value False.'], ['REFERENCE', '10.3.1.3'], None, None, None], 'source_encoding': 'utf-8-sig'}, 'parser_version': 'mib-4'}