This managed object specifies the OUI/CID used together with the encapsulation type specified in ieee8021FrerSequenceIdentificationEncodeEncapsulationType. It is used if and only if the value for ieee8021FrerSequenceIdentificationEncodeEncapsulationType is in the range of 0-255. In this case it always takes the value 00-80-C2.
Status in source: current.
Names: ieee8021FrerSequenceIdentificationEncodeEncapsulationOUI
Technical details
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"ieee8021FrerSequenceIdentificationEncodeEncapsulationOUI",
"OBJECT-TYPE",
"SYNTAX",
"OCTET",
"STRING",
"(",
"SIZE",
"(",
"3",
")",
")",
"MAX-ACCESS",
"read-only",
"STATUS",
"current",
"DESCRIPTION",
"\"This managed object specifies the OUI/CID used together with the encapsulation type specified in ieee8021FrerSequenceIdentificationEncodeEncapsulationType. It is used if and only if the value for ieee8021FrerSequenceIdentificationEncodeEncapsulationType is in the range of 0-255. In this case it always takes the value 00-80-C2.\"",
"REFERENCE",
"\"10.5.1.5\"",
"::=",
"{",
"ieee8021FrerSequenceIdentificationEntry",
"6",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"OCTET STRING",
[
"octetStringSubType",
[
[
3
]
]
]
],
null,
[
"MaxAccessPart",
"read-only"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"This managed object specifies the OUI/CID used together with the encapsulation type specified in ieee8021FrerSequenceIdentificationEncodeEncapsulationType. It is used if and only if the value for ieee8021FrerSequenceIdentificationEncodeEncapsulationType is in the range of 0-255. In this case it always takes the value 00-80-C2."
],
[
"REFERENCE",
"10.5.1.5"
],
null,
null,
null
]
}- IEEE 802
· Publisher's source file
· Archived source file
Source location: IEEE8021-FRER-MIB::ieee8021FrerSequenceIdentificationEncodeEncapsulationOUI.Source version and references
Downloaded: 2026-10-19T00:21:33.985475+00:00. SHA-256:
49835dfa7b21b0f0c35727922c63900636f0a07fd00cced17f9ec356e42bf30f{'kind': 'OBJECT-TYPE', 'details': {'module': 'IEEE8021-FRER-MIB', 'imports': {'IF-MIB': ['ifIndex', 'InterfaceIndex'], 'SNMPv2-TC': ['TEXTUAL-CONVENTION', 'TruthValue', 'RowStatus', 'AutonomousType', 'VariablePointer'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Counter64', 'Unsigned32', 'Integer32'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE'], 'IEEE8021-TC-MIB': ['ieee802dot1mibs'], 'IEEE8021-STREAM-IDENTIFICATION-MIB': ['Ieee8021CBTaggedType', 'Ieee8021CBVlanIdentifier', 'Ieee8021CBLanPathIdType', 'ieee8021StreamIdStreamIdHandle']}, 'smi_kind': 'OBJECT-TYPE', 'definition': 'ieee8021FrerSequenceIdentificationEncodeEncapsulationOUI OBJECT-TYPE\n SYNTAX OCTET STRING (SIZE (3))\n MAX-ACCESS read-only\n STATUS current\n DESCRIPTION\n "This managed object specifies the OUI/CID used together with\n the encapsulation type specified in\n ieee8021FrerSequenceIdentificationEncodeEncapsulationType.\n It is used if and only if the value for\n ieee8021FrerSequenceIdentificationEncodeEncapsulationType is\n in the range of 0-255. In this case it always takes the value\n 00-80-C2."\n REFERENCE "10.5.1.5"\n ::= { ieee8021FrerSequenceIdentificationEntry 6 }', 'syntax_tree': [['SimpleSyntax', 'OCTET STRING', ['octetStringSubType', [[3]]]], None, ['MaxAccessPart', 'read-only'], ['Status', 'current'], ['DESCRIPTION', 'This managed object specifies the OUI/CID used together with the encapsulation type specified in ieee8021FrerSequenceIdentificationEncodeEncapsulationType. It is used if and only if the value for ieee8021FrerSequenceIdentificationEncodeEncapsulationType is in the range of 0-255. In this case it always takes the value 00-80-C2.'], ['REFERENCE', '10.5.1.5'], None, None, None], 'source_encoding': 'utf-8-sig'}, 'parser_version': 'mib-4'}