This managed object indicates whether the instance of the Stream splitting function performing the stream_handle translations specified by ieee8021FrerStreamSplitInputIdList and ieee8021FrerStreamSplitOutputIdList is to be placed on the out-facing (True) or in-facing (False) side of the port.
Status in source: current.
Names: ieee8021FrerStreamSplitDirection
Technical details
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"ieee8021FrerStreamSplitDirection",
"OBJECT-TYPE",
"SYNTAX",
"TruthValue",
"MAX-ACCESS",
"read-create",
"STATUS",
"current",
"DESCRIPTION",
"\"This managed object indicates whether the instance of the Stream splitting function performing the stream_handle translations specified by ieee8021FrerStreamSplitInputIdList and ieee8021FrerStreamSplitOutputIdList is to be placed on the out-facing (True) or in-facing (False) side of the port.\"",
"REFERENCE",
"\"10.6.1.1\"",
"::=",
"{",
"ieee8021FrerStreamSplitEntry",
"3",
"}"
],
"syntax_tree": [
[
"row",
"TruthValue"
],
null,
[
"MaxAccessPart",
"read-create"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"This managed object indicates whether the instance of the Stream splitting function performing the stream_handle translations specified by ieee8021FrerStreamSplitInputIdList and ieee8021FrerStreamSplitOutputIdList is to be placed on the out-facing (True) or in-facing (False) side of the port."
],
[
"REFERENCE",
"10.6.1.1"
],
null,
null,
null
]
}- IEEE 802
· Publisher's source file
· Archived source file
Source location: IEEE8021-FRER-MIB::ieee8021FrerStreamSplitDirection.Source version and references
Downloaded: 2026-10-19T00:21:33.985475+00:00. SHA-256:
49835dfa7b21b0f0c35727922c63900636f0a07fd00cced17f9ec356e42bf30f{'kind': 'OBJECT-TYPE', 'details': {'module': 'IEEE8021-FRER-MIB', 'imports': {'IF-MIB': ['ifIndex', 'InterfaceIndex'], 'SNMPv2-TC': ['TEXTUAL-CONVENTION', 'TruthValue', 'RowStatus', 'AutonomousType', 'VariablePointer'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Counter64', 'Unsigned32', 'Integer32'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE'], 'IEEE8021-TC-MIB': ['ieee802dot1mibs'], 'IEEE8021-STREAM-IDENTIFICATION-MIB': ['Ieee8021CBTaggedType', 'Ieee8021CBVlanIdentifier', 'Ieee8021CBLanPathIdType', 'ieee8021StreamIdStreamIdHandle']}, 'smi_kind': 'OBJECT-TYPE', 'definition': 'ieee8021FrerStreamSplitDirection OBJECT-TYPE\n SYNTAX TruthValue\n MAX-ACCESS read-create\n STATUS current\n DESCRIPTION\n "This managed object indicates whether the instance of the\n Stream splitting function performing the stream_handle\n translations specified by ieee8021FrerStreamSplitInputIdList\n and ieee8021FrerStreamSplitOutputIdList is to be placed on the\n out-facing (True) or in-facing (False) side of the port."\n REFERENCE "10.6.1.1"\n ::= { ieee8021FrerStreamSplitEntry 3 }', 'syntax_tree': [['row', 'TruthValue'], None, ['MaxAccessPart', 'read-create'], ['Status', 'current'], ['DESCRIPTION', 'This managed object indicates whether the instance of the Stream splitting function performing the stream_handle translations specified by ieee8021FrerStreamSplitInputIdList and ieee8021FrerStreamSplitOutputIdList is to be placed on the out-facing (True) or in-facing (False) side of the port.'], ['REFERENCE', '10.6.1.1'], None, None, None], 'source_encoding': 'utf-8-sig'}, 'parser_version': 'mib-4'}