The entity of a single time-aware system that executes gPTP in one gPTP domain is called a PTP Instance. A time-aware system can contain multiple PTP Instances, which are each associated with a different gPTP domain. There are two types of PTP Instances, a PTP End Instance and a PTP Relay Instance.
Status in source: current.
Names: ieee8021AsV3PtpInstance
Technical details
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"ieee8021AsV3PtpInstance",
"OBJECT-TYPE",
"SYNTAX",
"Ieee8021ASV3PTPInstanceIdentifier",
"MAX-ACCESS",
"not-accessible",
"STATUS",
"current",
"DESCRIPTION",
"\"The entity of a single time-aware system that executes gPTP in one gPTP domain is called a PTP Instance. A time-aware system can contain multiple PTP Instances, which are each associated with a different gPTP domain. There are two types of PTP Instances, a PTP End Instance and a PTP Relay Instance.\"",
"REFERENCE",
"\"7.2.1\"",
"::=",
"{",
"ieee8021AsV3PtpInstanceEntry",
"1",
"}"
],
"syntax_tree": [
[
"row",
"Ieee8021ASV3PTPInstanceIdentifier"
],
null,
[
"MaxAccessPart",
"not-accessible"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"The entity of a single time-aware system that executes gPTP in one gPTP domain is called a PTP Instance. A time-aware system can contain multiple PTP Instances, which are each associated with a different gPTP domain. There are two types of PTP Instances, a PTP End Instance and a PTP Relay Instance."
],
[
"REFERENCE",
"7.2.1"
],
null,
null,
null
]
}- IEEE 802
· Publisher's source file
· Archived source file
Source location: IEEE8021-AS-V3-MIB::ieee8021AsV3PtpInstance.Source version and references
Downloaded: 2026-10-19T00:21:26.981307+00:00. SHA-256:
7ff3709990346689da5c9cbfffabf2529ce6183419a2c83fb38574811a42106e{'kind': 'OBJECT-TYPE', 'details': {'module': 'IEEE8021-AS-V3-MIB', 'imports': {'IF-MIB': ['InterfaceIndexOrZero'], 'SNMPv2-TC': ['TEXTUAL-CONVENTION', 'TruthValue', 'RowStatus', 'TimeStamp'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Integer32', 'Counter32'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP'], 'FLOAT-TC-MIB': ['Float64TC'], 'IEEE8021-TC-MIB': ['IEEE8021BridgePortNumber'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}, 'smi_kind': 'OBJECT-TYPE', 'definition': 'ieee8021AsV3PtpInstance OBJECT-TYPE\r\n SYNTAX Ieee8021ASV3PTPInstanceIdentifier\r\n MAX-ACCESS not-accessible\r\n STATUS current\r\n DESCRIPTION\r\n "The entity of a single time-aware system that executes gPTP in\r\n one gPTP domain is called a PTP Instance. A time-aware system can\r\n contain multiple PTP Instances, which are each associated with\r\n a different gPTP domain. There are two types of PTP Instances,\r\n a PTP End Instance and a PTP Relay Instance."\r\n REFERENCE "7.2.1"\r\n ::= { ieee8021AsV3PtpInstanceEntry 1 }', 'syntax_tree': [['row', 'Ieee8021ASV3PTPInstanceIdentifier'], None, ['MaxAccessPart', 'not-accessible'], ['Status', 'current'], ['DESCRIPTION', 'The entity of a single time-aware system that executes gPTP in one gPTP domain is called a PTP Instance. A time-aware system can contain multiple PTP Instances, which are each associated with a different gPTP domain. There are two types of PTP Instances, a PTP End Instance and a PTP Relay Instance.'], ['REFERENCE', '7.2.1'], None, None, None], 'source_encoding': 'utf-8-sig'}, 'parser_version': 'mib-4'}