The managed object is a Boolean that determines the source of the gPTP capable message interval. If the value is TRUE (1), the value of currentLogGptpCapableMessageInterval is set equal to the value of mgtSettableLogGptpCapableMessageInterval. If the value of the managed object is FALSE (2), the value of currentLogGptpCapableMessageInterval is determined by the GptpCapableMessageIntervalSetting state machine. The default value of useMgtSettableLogGptpCapableMessageInterval is FALSE (2).
Status in source: current.
Names: ieee8021AsV3PortDSUseMgtSettableLogGptpCapableMessageInterval
Technical details
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"ieee8021AsV3PortDSUseMgtSettableLogGptpCapableMessageInterval",
"OBJECT-TYPE",
"SYNTAX",
"TruthValue",
"MAX-ACCESS",
"read-write",
"STATUS",
"current",
"DESCRIPTION",
"\"The managed object is a Boolean that determines the source of the gPTP capable message interval. If the value is TRUE (1), the value of currentLogGptpCapableMessageInterval is set equal to the value of mgtSettableLogGptpCapableMessageInterval. If the value of the managed object is FALSE (2), the value of currentLogGptpCapableMessageInterval is determined by the GptpCapableMessageIntervalSetting state machine. The default value of useMgtSettableLogGptpCapableMessageInterval is FALSE (2).\"",
"REFERENCE",
"\"14.10.30\"",
"DEFVAL",
"{",
"false",
"}",
"::=",
"{",
"ieee8021AsV3PortDSEntry",
"31",
"}"
],
"syntax_tree": [
[
"row",
"TruthValue"
],
null,
[
"MaxAccessPart",
"read-write"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"The managed object is a Boolean that determines the source of the gPTP capable message interval. If the value is TRUE (1), the value of currentLogGptpCapableMessageInterval is set equal to the value of mgtSettableLogGptpCapableMessageInterval. If the value of the managed object is FALSE (2), the value of currentLogGptpCapableMessageInterval is determined by the GptpCapableMessageIntervalSetting state machine. The default value of useMgtSettableLogGptpCapableMessageInterval is FALSE (2)."
],
[
"REFERENCE",
"14.10.30"
],
null,
null,
[
"DEFVAL",
"false"
]
]
}- IEEE 802
· Publisher's source file
· Archived source file
Source location: IEEE8021-AS-V3-MIB::ieee8021AsV3PortDSUseMgtSettableLogGptpCapableMessageInterval.Source version and references
Downloaded: 2026-10-19T00:21:26.981307+00:00. SHA-256:
7ff3709990346689da5c9cbfffabf2529ce6183419a2c83fb38574811a42106e{'kind': 'OBJECT-TYPE', 'details': {'module': 'IEEE8021-AS-V3-MIB', 'imports': {'IF-MIB': ['InterfaceIndexOrZero'], 'SNMPv2-TC': ['TEXTUAL-CONVENTION', 'TruthValue', 'RowStatus', 'TimeStamp'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Integer32', 'Counter32'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP'], 'FLOAT-TC-MIB': ['Float64TC'], 'IEEE8021-TC-MIB': ['IEEE8021BridgePortNumber'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}, 'smi_kind': 'OBJECT-TYPE', 'definition': 'ieee8021AsV3PortDSUseMgtSettableLogGptpCapableMessageInterval OBJECT-TYPE\r\n SYNTAX TruthValue\r\n MAX-ACCESS read-write\r\n STATUS current\r\n DESCRIPTION\r\n "The managed object is a Boolean that determines the source\r\n of the gPTP capable message interval. If the value is\r\n TRUE (1), the value of currentLogGptpCapableMessageInterval\r\n is set equal to the value of\r\n mgtSettableLogGptpCapableMessageInterval. If the value of\r\n the managed object is FALSE (2), the value of\r\n currentLogGptpCapableMessageInterval is determined by the\r\n GptpCapableMessageIntervalSetting state machine.\r\n The default value of\r\n useMgtSettableLogGptpCapableMessageInterval is FALSE (2)."\r\n REFERENCE "14.10.30"\r\n DEFVAL { false }\r\n ::= { ieee8021AsV3PortDSEntry 31 }', 'syntax_tree': [['row', 'TruthValue'], None, ['MaxAccessPart', 'read-write'], ['Status', 'current'], ['DESCRIPTION', 'The managed object is a Boolean that determines the source of the gPTP capable message interval. If the value is TRUE (1), the value of currentLogGptpCapableMessageInterval is set equal to the value of mgtSettableLogGptpCapableMessageInterval. If the value of the managed object is FALSE (2), the value of currentLogGptpCapableMessageInterval is determined by the GptpCapableMessageIntervalSetting state machine. The default value of useMgtSettableLogGptpCapableMessageInterval is FALSE (2).'], ['REFERENCE', '14.10.30'], None, None, ['DEFVAL', 'false']], 'source_encoding': 'utf-8-sig'}, 'parser_version': 'mib-4'}