A TRUE (1) value indicates that the last minute of the current UTC day, relative to the ClockTimeTransmitter entity of this PTP Instance, will contain 61 s. It is equal to the global variable sysLeap61. The value is selected as follows: a)The value is obtained from a primary reference if known at the time of initialization, else b)The value is set to FALSE (2).
Status in source: current.
Names: ieee8021AsV3DefaultDSLeap61
Technical details
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"ieee8021AsV3DefaultDSLeap61",
"OBJECT-TYPE",
"SYNTAX",
"TruthValue",
"MAX-ACCESS",
"read-only",
"STATUS",
"current",
"DESCRIPTION",
"\"A TRUE (1) value indicates that the last minute of the current UTC day, relative to the ClockTimeTransmitter entity of this PTP Instance, will contain 61 s. It is equal to the global variable sysLeap61. The value is selected as follows: a)The value is obtained from a primary reference if known at the time of initialization, else b)The value is set to FALSE (2).\"",
"REFERENCE",
"\"14.2.11\"",
"::=",
"{",
"ieee8021AsV3DefaultDSEntry",
"12",
"}"
],
"syntax_tree": [
[
"row",
"TruthValue"
],
null,
[
"MaxAccessPart",
"read-only"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"A TRUE (1) value indicates that the last minute of the current UTC day, relative to the ClockTimeTransmitter entity of this PTP Instance, will contain 61 s. It is equal to the global variable sysLeap61. The value is selected as follows: a)The value is obtained from a primary reference if known at the time of initialization, else b)The value is set to FALSE (2)."
],
[
"REFERENCE",
"14.2.11"
],
null,
null,
null
]
}- IEEE 802
· Publisher's source file
· Archived source file
Source location: IEEE8021-AS-V3-MIB::ieee8021AsV3DefaultDSLeap61.Source version and references
Downloaded: 2026-10-19T00:21:26.981307+00:00. SHA-256:
7ff3709990346689da5c9cbfffabf2529ce6183419a2c83fb38574811a42106e{'kind': 'OBJECT-TYPE', 'details': {'module': 'IEEE8021-AS-V3-MIB', 'imports': {'IF-MIB': ['InterfaceIndexOrZero'], 'SNMPv2-TC': ['TEXTUAL-CONVENTION', 'TruthValue', 'RowStatus', 'TimeStamp'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Integer32', 'Counter32'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP'], 'FLOAT-TC-MIB': ['Float64TC'], 'IEEE8021-TC-MIB': ['IEEE8021BridgePortNumber'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}, 'smi_kind': 'OBJECT-TYPE', 'definition': 'ieee8021AsV3DefaultDSLeap61 OBJECT-TYPE\r\n SYNTAX TruthValue\r\n MAX-ACCESS read-only\r\n STATUS current\r\n DESCRIPTION\r\n "A TRUE (1) value indicates that the last minute of the\r\n current UTC day, relative to the ClockTimeTransmitter entity of\r\n this PTP Instance, will contain 61 s. It is equal to the global\r\n variable sysLeap61.\r\n\r\n The value is selected as follows:\r\n a)The value is obtained from a primary reference if\r\n known at the time of initialization, else\r\n b)The value is set to FALSE (2)."\r\n REFERENCE "14.2.11"\r\n ::= { ieee8021AsV3DefaultDSEntry 12 }', 'syntax_tree': [['row', 'TruthValue'], None, ['MaxAccessPart', 'read-only'], ['Status', 'current'], ['DESCRIPTION', 'A TRUE (1) value indicates that the last minute of the current UTC day, relative to the ClockTimeTransmitter entity of this PTP Instance, will contain 61 s. It is equal to the global variable sysLeap61. The value is selected as follows: a)The value is obtained from a primary reference if known at the time of initialization, else b)The value is set to FALSE (2).'], ['REFERENCE', '14.2.11'], None, None, None], 'source_encoding': 'utf-8-sig'}, 'parser_version': 'mib-4'}