OID reference

J2CLayout

1.3.52.1.1.1.14.4.1.6.3.14.0.0.0

Description

The nature and order of the image components in the compressed domain as carried in the J2C codestream.

Full description and source information

Identification

Identifier and names

Parent
1.3.52.1.1.1.14.4.1.6.3.14.0.0 (0)
Node code
0
Node name
J2CLayout
Numeric OID
1.3.52.1.1.1.14.4.1.6.3.14.0.0.0
URN notation
urn:oid:1.3.52.1.1.1.14.4.1.6.3.14.0.0.0
ASN.1, OID-IRI and named path variants
ASN.1 notation

{1 3 52 1 1 1 14 4 1 6 3 14 0 0 0}

  • {iso(1) identified-organization(3) smpte(52) 1 1 1 14 4 1 6 3 14 0 0 0}
  • {iso(1) org(3) smpte(52) 1 1 1 14 4 1 6 3 14 0 0 0}
  • {iso(1) iso-identified-organization(3) smpte(52) 1 1 1 14 4 1 6 3 14 0 0 0}
  • {iso(1) iso-organization(3) smpte(52) 1 1 1 14 4 1 6 3 14 0 0 0}
OID-IRI notation
  • /1/3/52/1/1/1/14/4/1/6/3/14/0/0/0
  • /ISO/Identified-Organization/52/1/1/1/14/4/1/6/3/14/0/0/0
  • /ISO/3/52/1/1/1/14/4/1/6/3/14/0/0/0
Named path variants
  • /iso/identified-organization/smpte/1/1/1/14/4/1/6/3/14/0/0/J2CLayout
  • /iso/org/smpte/1/1/1/14/4/1/6/3/14/0/0/J2CLayout
  • /iso/iso-identified-organization/smpte/1/1/1/14/4/1/6/3/14/0/0/J2CLayout
  • /iso/iso-organization/smpte/1/1/1/14/4/1/6/3/14/0/0/J2CLayout

Meaning

Descriptions

1 unique

Identical descriptions are grouped. Different wording and device-specific notes are retained.

The nature and order of the image components in the compressed domain as carried in the J2C codestream.

Sources for this description

SMPTE published registers

See 1 matching source record

Evidence

Source records

1 records

Matching descriptions are grouped; open a group to compare definitions and supporting files.

Records for description 1SMPTE published registers1 record · 1 source

Description 1

J2CLayout · publishedSMPTE published registers1 source

Status in source: published.

Names: J2CLayout

Technical details
{
  "ber_encoding": {
    "tag": 6,
    "rule": "SMPTE ST 298:2009 clause 8.1 / ISO/IEC 8825-1 BER; preserve all arcs inside declared value",
    "container_bytes": 16,
    "outer_zero_padding": 0,
    "declared_value_length": 14
  },
  "published_entry": {
    "UL": [
      "urn:smpte:ul:060e2b34.0101010e.04010603.0e000000"
    ],
    "Kind": [
      "LEAF"
    ],
    "Name": [
      "J2C Layout"
    ],
    "Type": [
      "urn:smpte:ul:060e2b34.01040101.04020100.00000000"
    ],
    "Symbol": [
      "J2CLayout"
    ],
    "Register": [
      "Elements"
    ],
    "Definition": [
      "The nature and order of the image components in the compressed domain as carried in the J2C codestream."
    ],
    "ValueLength": [
      "variable"
    ],
    "ContextScope": [
      "UnknownContext"
    ],
    "IsDeprecated": [
      "false"
    ],
    "NamespaceName": [
      "http://www.smpte-ra.org/reg/335/2012"
    ],
    "DefiningDocument": [
      "SMPTE ST422"
    ]
  },
  "universal_label": "urn:smpte:ul:060e2b34.0101010e.04010603.0e000000"
}

Registration

Registration authorities

First Registration Authority (inferred from ancestor 1.3.52)

Society of Motion Picture and Television Engineers (SMPTE)

Current Registration Authority (inferred from ancestor 1.3)

Frank Farance