The value of this parameter specifies whether the SDUs on the service flow are fixed-length (0) or variable-length (1). The parameter is used only if packing is on for the service flow. The default value is 0, i.e., variable-length SDUs.
Status in source: current.
Names: wmanIfBsQoSFixedVsVariableSduInd
Technical details
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"wmanIfBsQoSFixedVsVariableSduInd",
"OBJECT-TYPE",
"SYNTAX",
"INTEGER",
"{",
"variableLength",
"(",
"0",
")",
",",
"fixedLength",
"(",
"1",
")",
"}",
"MAX-ACCESS",
"read-create",
"STATUS",
"current",
"DESCRIPTION",
"\"The value of this parameter specifies whether the SDUs on the service flow are fixed-length (0) or variable-length (1). The parameter is used only if packing is on for the service flow. The default value is 0, i.e., variable-length SDUs.\"",
"REFERENCE",
"\"Section 11.13.15 in IEEE 802.16REVd/D5-2004\"",
"DEFVAL",
"{",
"0",
"}",
"::=",
"{",
"wmanIfBsServiceClassEntry",
"9",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"INTEGER",
[
"enumSpec",
[
[
"variableLength",
0
],
[
"fixedLength",
1
]
]
]
],
null,
[
"MaxAccessPart",
"read-create"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"The value of this parameter specifies whether the SDUs on the service flow are fixed-length (0) or variable-length (1). The parameter is used only if packing is on for the service flow. The default value is 0, i.e., variable-length SDUs."
],
[
"REFERENCE",
"Section 11.13.15 in IEEE 802.16REVd/D5-2004"
],
null,
null,
[
"DEFVAL",
0
]
]
}- etsi-formal
· Publisher's source file
Source location: PDF page 24/WMAN-IF-MIB::wmanIfBsQoSFixedVsVariableSduInd.Source version and references
Published package: ETSI TS 102389 1.1.1; file: ts_102389v010101p.pdf.
Downloaded: 2026-10-19T23:15:36.254096+00:00. SHA-256:
624ae041d6abee4b6cf0a5b3bf2ae2b0e602a96229c82d5ac5ed39f9c531f2d1{'kind': 'OBJECT-TYPE', 'details': {'module': 'WMAN-IF-MIB', 'imports': {'IF-MIB': ['ifIndex', 'InterfaceIndexOrZero'], 'SNMPv2-TC': ['TEXTUAL-CONVENTION', 'MacAddress', 'RowStatus', 'TruthValue', 'DateAndTime', 'DisplayString', 'TimeInterval', 'TimeStamp'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'Unsigned32', 'Integer32', 'Counter32', 'Counter64', 'TimeTicks', 'IpAddress', 'transmission'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}, 'document': {'language': 'pdf', 'pdf_page': 24, 'software': 'ETSI TS 102389', 'extraction_note': 'Definition is pdftotext output; locate it by module/symbol on the stated physical PDF page, not by a claimed byte offset', 'release_version': '1.1.1'}, 'smi_kind': 'OBJECT-TYPE', 'definition': 'wmanIfBsQoSFixedVsVariableSduInd OBJECT-TYPE\n SYNTAX INTEGER {variableLength(0),\n fixedLength(1)}\n MAX-ACCESS read-create\n STATUS current\n DESCRIPTION\n "The value of this parameter specifies whether the SDUs\n on the service flow are fixed-length (0) or\n variable-length (1). The parameter is used only if\n packing is on for the service flow. The default value\n is 0, i.e., variable-length SDUs."\n REFERENCE\n "Section 11.13.15 in IEEE 802.16REVd/D5-2004"\n DEFVAL { 0 }\n ::= { wmanIfBsServiceClassEntry 9 }', 'syntax_tree': [['SimpleSyntax', 'INTEGER', ['enumSpec', [['variableLength', 0], ['fixedLength', 1]]]], None, ['MaxAccessPart', 'read-create'], ['Status', 'current'], ['DESCRIPTION', 'The value of this parameter specifies whether the SDUs on the service flow are fixed-length (0) or variable-length (1). The parameter is used only if packing is on for the service flow. The default value is 0, i.e., variable-length SDUs.'], ['REFERENCE', 'Section 11.13.15 in IEEE 802.16REVd/D5-2004'], None, None, ['DEFVAL', 0]], 'source_encoding': 'utf-8-sig'}, 'parser_version': 'formal-3-q1'}