OID reference

sonetLineCurrentSESs

1.3.6.1.2.1.10.39.1.3.1.1.3

Description

The counter associated with the number of Severely Errored Seconds encountered by a SONET/SDH Line in the current 15 minute interval.

Full description and source information

Identification

Identifier and names

Parent
1.3.6.1.2.1.10.39.1.3.1.1 (sonetLineCurrentEntry)
Node code
3
Node name
sonetLineCurrentSESs
Category
SNMP management object
Numeric OID
1.3.6.1.2.1.10.39.1.3.1.1.3
URN notation
urn:oid:1.3.6.1.2.1.10.39.1.3.1.1.3
Type
OBJECT-TYPE
ASN.1, OID-IRI and named path variants
ASN.1 notation

{1 3 6 1 2 1 10 39 1 3 1 1 3}

  • {iso(1) identified-organization(3) dod(6) internet(1) mgmt(2) mib-2(1) transmission(10) sonetMIB(39) sonetObjects(1) sonetLine(3) sonetLineCurrentTable(1) sonetLineCurrentEntry(1) sonetLineCurrentSESs(3)}
  • {iso(1) identified-organization(3) dod(6) internet(1) mgmt(2) mib(1) transmission(10) sonetMIB(39) sonetObjects(1) sonetLine(3) sonetLineCurrentTable(1) sonetLineCurrentEntry(1) sonetLineCurrentSESs(3)}
  • {iso(1) identified-organization(3) dod(6) internet(1) mgmt(2) stdmib-2(1) transmission(10) sonetMIB(39) sonetObjects(1) sonetLine(3) sonetLineCurrentTable(1) sonetLineCurrentEntry(1) sonetLineCurrentSESs(3)}
  • {iso(1) org(3) dod(6) internet(1) mgmt(2) mib-2(1) transmission(10) sonetMIB(39) sonetObjects(1) sonetLine(3) sonetLineCurrentTable(1) sonetLineCurrentEntry(1) sonetLineCurrentSESs(3)}
  • {iso(1) org(3) dod(6) internet(1) mgmt(2) mib(1) transmission(10) sonetMIB(39) sonetObjects(1) sonetLine(3) sonetLineCurrentTable(1) sonetLineCurrentEntry(1) sonetLineCurrentSESs(3)}
  • {iso(1) org(3) dod(6) internet(1) mgmt(2) stdmib-2(1) transmission(10) sonetMIB(39) sonetObjects(1) sonetLine(3) sonetLineCurrentTable(1) sonetLineCurrentEntry(1) sonetLineCurrentSESs(3)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) mgmt(2) mib-2(1) transmission(10) sonetMIB(39) sonetObjects(1) sonetLine(3) sonetLineCurrentTable(1) sonetLineCurrentEntry(1) sonetLineCurrentSESs(3)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) mgmt(2) mib(1) transmission(10) sonetMIB(39) sonetObjects(1) sonetLine(3) sonetLineCurrentTable(1) sonetLineCurrentEntry(1) sonetLineCurrentSESs(3)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) mgmt(2) stdmib-2(1) transmission(10) sonetMIB(39) sonetObjects(1) sonetLine(3) sonetLineCurrentTable(1) sonetLineCurrentEntry(1) sonetLineCurrentSESs(3)}
  • {iso(1) iso-organization(3) dod(6) internet(1) mgmt(2) mib-2(1) transmission(10) sonetMIB(39) sonetObjects(1) sonetLine(3) sonetLineCurrentTable(1) sonetLineCurrentEntry(1) sonetLineCurrentSESs(3)}
  • {iso(1) iso-organization(3) dod(6) internet(1) mgmt(2) mib(1) transmission(10) sonetMIB(39) sonetObjects(1) sonetLine(3) sonetLineCurrentTable(1) sonetLineCurrentEntry(1) sonetLineCurrentSESs(3)}
  • {iso(1) iso-organization(3) dod(6) internet(1) mgmt(2) stdmib-2(1) transmission(10) sonetMIB(39) sonetObjects(1) sonetLine(3) sonetLineCurrentTable(1) sonetLineCurrentEntry(1) sonetLineCurrentSESs(3)}
OID-IRI notation
  • /1/3/6/1/2/1/10/39/1/3/1/1/3
  • /ISO/Identified-Organization/6/1/2/1/10/39/1/3/1/1/3
  • /ISO/3/6/1/2/1/10/39/1/3/1/1/3
Named path variants
  • /iso/identified-organization/dod/internet/mgmt/mib-2/transmission/sonetMIB/sonetObjects/sonetLine/sonetLineCurrentTable/sonetLineCurrentEntry/sonetLineCurrentSESs
  • /iso/identified-organization/dod/internet/mgmt/mib/transmission/sonetMIB/sonetObjects/sonetLine/sonetLineCurrentTable/sonetLineCurrentEntry/sonetLineCurrentSESs
  • /iso/identified-organization/dod/internet/mgmt/RFC1066-MIB-INTERPRETATION/transmission/sonetMIB/sonetObjects/sonetLine/sonetLineCurrentTable/sonetLineCurrentEntry/sonetLineCurrentSESs
  • /iso/identified-organization/dod/internet/mgmt/stdmib-2/transmission/sonetMIB/sonetObjects/sonetLine/sonetLineCurrentTable/sonetLineCurrentEntry/sonetLineCurrentSESs
  • /iso/org/dod/internet/mgmt/mib-2/transmission/sonetMIB/sonetObjects/sonetLine/sonetLineCurrentTable/sonetLineCurrentEntry/sonetLineCurrentSESs
  • /iso/org/dod/internet/mgmt/mib/transmission/sonetMIB/sonetObjects/sonetLine/sonetLineCurrentTable/sonetLineCurrentEntry/sonetLineCurrentSESs
  • /iso/org/dod/internet/mgmt/RFC1066-MIB-INTERPRETATION/transmission/sonetMIB/sonetObjects/sonetLine/sonetLineCurrentTable/sonetLineCurrentEntry/sonetLineCurrentSESs
  • /iso/org/dod/internet/mgmt/stdmib-2/transmission/sonetMIB/sonetObjects/sonetLine/sonetLineCurrentTable/sonetLineCurrentEntry/sonetLineCurrentSESs
  • /iso/iso-identified-organization/dod/internet/mgmt/mib-2/transmission/sonetMIB/sonetObjects/sonetLine/sonetLineCurrentTable/sonetLineCurrentEntry/sonetLineCurrentSESs
  • /iso/iso-identified-organization/dod/internet/mgmt/mib/transmission/sonetMIB/sonetObjects/sonetLine/sonetLineCurrentTable/sonetLineCurrentEntry/sonetLineCurrentSESs
  • /iso/iso-identified-organization/dod/internet/mgmt/RFC1066-MIB-INTERPRETATION/transmission/sonetMIB/sonetObjects/sonetLine/sonetLineCurrentTable/sonetLineCurrentEntry/sonetLineCurrentSESs
  • /iso/iso-identified-organization/dod/internet/mgmt/stdmib-2/transmission/sonetMIB/sonetObjects/sonetLine/sonetLineCurrentTable/sonetLineCurrentEntry/sonetLineCurrentSESs
  • /iso/iso-organization/dod/internet/mgmt/mib-2/transmission/sonetMIB/sonetObjects/sonetLine/sonetLineCurrentTable/sonetLineCurrentEntry/sonetLineCurrentSESs
  • /iso/iso-organization/dod/internet/mgmt/mib/transmission/sonetMIB/sonetObjects/sonetLine/sonetLineCurrentTable/sonetLineCurrentEntry/sonetLineCurrentSESs
  • /iso/iso-organization/dod/internet/mgmt/RFC1066-MIB-INTERPRETATION/transmission/sonetMIB/sonetObjects/sonetLine/sonetLineCurrentTable/sonetLineCurrentEntry/sonetLineCurrentSESs
  • /iso/iso-organization/dod/internet/mgmt/stdmib-2/transmission/sonetMIB/sonetObjects/sonetLine/sonetLineCurrentTable/sonetLineCurrentEntry/sonetLineCurrentSESs

SNMP properties

Value type
Gauge, Gauge32, PerfCurrentCount
Maximum access defined by MIB
read-only
Status in MIB
mandatory, current

Definitions may combine these properties differently.

Compare 5 source variants

Variant 1 — MIBdepot

Value type
Gauge
Maximum access defined by MIB
read-only
Status in MIB
mandatory

Variant 2 — MIBdepot, RFC Editor

Value type
Gauge32
Maximum access defined by MIB
read-only
Status in MIB
current

Variant 3 — MIBdepot

Value type
Gauge32
Maximum access defined by MIB
read-only
Status in MIB
mandatory

Variant 4 — MIBdepot, Cisco, and others

Value type
PerfCurrentCount
Maximum access defined by MIB
read-only
Status in MIB
current

Variant 5 — Cisco SMIv1

Value type
PerfCurrentCount
Maximum access defined by MIB
read-only
Status in MIB
mandatory

Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.

Product context

Documented MIB packages

The FS.COM catalogue lists MIB packages containing this definition for these models:

N5860-48SC, N8560-32C, N8560-48BC, N8560-64C, NC8200-16Q, NC8200-24BC, NC8200-4TD, NC8200-8C, NC8400-16CD, NC8400-32C, NC8400-4TH, S3100-16TF.

Show 11 more models

S3410-24TS-P, S3910-24TS, S3910-48TS, S5810-28FS, S5810-28TS, S5810-48FS, S5810-48TS, S5810-48TS-P, S5860-20SQ, S5860-24XB-U, S5860-48SC.

A definition in a model's MIB package does not establish that the device implements it or permits access.

Available source records contain 8 distinct definitions; some records may not include a definition.

Show 8 published definitions

sonetLineCurrentSESs · mandatory

sonetLineCurrentSESs OBJECT-TYPE
              SYNTAX  Gauge
              ACCESS  read-only
              STATUS  mandatory
              DESCRIPTION
               "The counter associated with the number of
               Severely Errored Seconds
               encountered by a SONET/SDH Line in the current 15
               minute
               interval."
              ::= { sonetLineCurrentEntry 3 }

sonetLineCurrentSESs · mandatory

sonetLineCurrentSESs OBJECT-TYPE
    SYNTAX  Gauge
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
           "The counter associated with the number of
               Severely Errored Seconds
               encountered by a SONET/SDH Line in the current 15
               minute
               interval."
    ::= { sonetLineCurrentEntry  3 }

sonetLineCurrentSESs · current

sonetLineCurrentSESs OBJECT-TYPE
              SYNTAX  Gauge32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
               "The counter associated with the number of
               Severely Errored Seconds
               encountered by a SONET/SDH Line in the current 15
               minute
               interval."
              ::= { sonetLineCurrentEntry 3 }

sonetLineCurrentSESs · current

sonetLineCurrentSESs OBJECT-TYPE
              SYNTAX  Gauge32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
               "The counter associated with the number of
               Severely Errored Seconds
               encountered by a SONET/SDH Line in the current 15
               minute
               interval."
              ::= { sonetLineCurrentEntry 3 }

sonetLineCurrentSESs · mandatory

sonetLineCurrentSESs OBJECT-TYPE
    SYNTAX Gauge32
    ACCESS read-only
    STATUS mandatory
    DESCRIPTION
        "The counter associated with the number of
        Severely Errored Seconds
        encountered by a SONET/SDH Line in the current 15
        minute
        interval."
    ::= { sonetLineCurrentEntry 3 }

sonetLineCurrentSESs · mandatory

sonetLineCurrentSESs OBJECT-TYPE
    SYNTAX  Gauge32
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
           "The counter associated with the number of
               Severely Errored Seconds
               encountered by a SONET/SDH Line in the current 15
               minute
               interval."
    ::= { sonetLineCurrentEntry  3 }

sonetLineCurrentSESs · mandatory

sonetLineCurrentSESs OBJECT-TYPE
    SYNTAX Gauge32
    ACCESS read-only
    STATUS mandatory
    DESCRIPTION
        "The counter associated with the number of
        Severely Errored Seconds
        encountered by a SONET/SDH Line in the current 15
        minute
        interval."
    ::= { sonetLineCurrentEntry 3 }

sonetLineCurrentSESs · current

sonetLineCurrentSESs OBJECT-TYPE
    SYNTAX  PerfCurrentCount
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
     "The counter associated with the number of
     Severely Errored Seconds
     encountered by a SONET/SDH Line in the current 15
     minute



Tesink                      Standards Track                    [Page 29]

RFC 2558                   SONET/SDH Objects                  March 1999


     interval."
    ::= { sonetLineCurrentEntry 3 }

Meaning

Descriptions

2 unique

Identical descriptions are grouped. Different wording and device-specific notes are retained.

Description 1

The counter associated with the number of Severely Errored Seconds encountered by a SONET/SDH Line in the current 15 minute interval.
Original text from OID Repository
sonetLineCurrentSESs OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of
Severely Errored Seconds
encountered by a SONET/SDH Line in the current 15
minute
interval."
Sources for this description

MIBdepotRFC Editor

See 3 matching source records

OID Repository

View at oid-base.com
Automatically extracted from Cisco "SNMP v2 MIBs".

Circitor

Parsed from SONET-MIB.mib · SONET-MIB

Source file: Download SONET-MIB.mib

Browse all files from Circitor

Cisco

Source file: Download SONET-MIB.txt · Publisher's file

Vendor MIB copy from the Netdisco archive.

Source file: Download SONET-MIB · Publisher's file

Vendor MIB copy from the LibreNMS archive.

Source file: Download SONET-MIB-2558.mib · Publisher's file

Other official packages with the same file

s3100-16tf-switch-snmp-mib-files.zip

s5860-series-swithes-snmp-mib-files.zip

s3910-series-swithes-snmp-mib-files.zip

s3410-series-swithes-snmp-mib-files.zip

Source file: Download SONET-MIB · Publisher's file

Vendor MIB copy from the Observium Community archive.

Related source files and packages:

Source file: Download SONET-2558.mib · Publisher's file

Related source files and packages:

Show more related files and packages
Other official packages with the same file

3610.zip

3610.zip

3610.zip

3610-MIB.rar

Source file: Download rfc3592.txt · Publisher's file Junos OS Evolved 26.2R1

Other official packages with the same file

Junos OS 26.2R1

Source file: Download SONET-MIB.my · Publisher's file

Source file: Download RFC 3592 · Publisher's file · RFC errata

Source file: Download RFC 2558 · Publisher's file · RFC errata

Browse all files from Cisco

Description 2

The counter associated with the number of Severely Errored Seconds encountered by a SONET/SDH Line in the current 15 minute Tesink Standards Track [Page 29] RFC 2558 SONET/SDH Objects March 1999 interval.

Sources for this description

MIBdepot

See 1 matching source record

Evidence

Source records

4 records

Matching descriptions are grouped; open a group to compare definitions and supporting files.

Records for description 1MIBdepot, RFC Editor3 records · 11 sources

Description 1

sonetLineCurrentSESs · mandatoryMIBdepot2 sources

Status in source: mandatory.

Names: sonetLineCurrentSESs

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "sonetLineCurrentSESs",
    "OBJECT-TYPE",
    "SYNTAX",
    "Gauge",
    "ACCESS",
    "read-only",
    "STATUS",
    "mandatory",
    "DESCRIPTION",
    "\"The counter associated with the number of Severely Errored Seconds encountered by a SONET/SDH Line in the current 15 minute interval.\"",
    "::=",
    "{",
    "sonetLineCurrentEntry",
    "3",
    "}"
  ],
  "syntax_tree": [
    [
      "ApplicationSyntax",
      "Gauge"
    ],
    null,
    [
      "MaxAccessPart",
      "read-only"
    ],
    [
      "Status",
      "mandatory"
    ],
    [
      "DESCRIPTION",
      "The counter associated with the number of Severely Errored Seconds encountered by a SONET/SDH Line in the current 15 minute interval."
    ],
    null,
    null,
    null,
    null
  ]
}
sonetLineCurrentSESs · currentMIBdepot, RFC Editor5 sources

Status in source: current.

Names: sonetLineCurrentSESs

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "sonetLineCurrentSESs",
    "OBJECT-TYPE",
    "SYNTAX",
    "Gauge32",
    "MAX-ACCESS",
    "read-only",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"The counter associated with the number of Severely Errored Seconds encountered by a SONET/SDH Line in the current 15 minute interval.\"",
    "::=",
    "{",
    "sonetLineCurrentEntry",
    "3",
    "}"
  ],
  "syntax_tree": [
    [
      "ApplicationSyntax",
      "Gauge32"
    ],
    null,
    [
      "MaxAccessPart",
      "read-only"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "The counter associated with the number of Severely Errored Seconds encountered by a SONET/SDH Line in the current 15 minute interval."
    ],
    null,
    null,
    null,
    null
  ]
}
sonetLineCurrentSESs · mandatoryMIBdepot4 sources

Status in source: mandatory.

Names: sonetLineCurrentSESs

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "sonetLineCurrentSESs",
    "OBJECT-TYPE",
    "SYNTAX",
    "Gauge32",
    "ACCESS",
    "read-only",
    "STATUS",
    "mandatory",
    "DESCRIPTION",
    "\"The counter associated with the number of Severely Errored Seconds encountered by a SONET/SDH Line in the current 15 minute interval.\"",
    "::=",
    "{",
    "sonetLineCurrentEntry",
    "3",
    "}"
  ],
  "syntax_tree": [
    [
      "ApplicationSyntax",
      "Gauge32"
    ],
    null,
    [
      "MaxAccessPart",
      "read-only"
    ],
    [
      "Status",
      "mandatory"
    ],
    [
      "DESCRIPTION",
      "The counter associated with the number of Severely Errored Seconds encountered by a SONET/SDH Line in the current 15 minute interval."
    ],
    null,
    null,
    null,
    null
  ]
}
Records for description 2MIBdepot1 record · 1 source

Description 2

sonetLineCurrentSESs · currentMIBdepot1 source

Status in source: current.

Names: sonetLineCurrentSESs

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "sonetLineCurrentSESs",
    "OBJECT-TYPE",
    "SYNTAX",
    "PerfCurrentCount",
    "MAX-ACCESS",
    "read-only",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"The counter associated with the number of Severely Errored Seconds encountered by a SONET/SDH Line in the current 15 minute Tesink Standards Track [Page 29] RFC 2558 SONET/SDH Objects March 1999 interval.\"",
    "::=",
    "{",
    "sonetLineCurrentEntry",
    "3",
    "}"
  ],
  "syntax_tree": [
    [
      "row",
      "PerfCurrentCount"
    ],
    null,
    [
      "MaxAccessPart",
      "read-only"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "The counter associated with the number of Severely Errored Seconds encountered by a SONET/SDH Line in the current 15 minute Tesink Standards Track [Page 29] RFC 2558 SONET/SDH Objects March 1999 interval."
    ],
    null,
    null,
    null,
    null
  ]
}
  • Preserved mibdepot archive

    Module: SONET-MIB

    See published definition above

    Module imports
    {'IF-MIB': ['ifIndex'], 'SNMPv2-TC': ['DisplayString', 'TruthValue'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Integer32', 'transmission'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP'], 'PerfHist-TC-MIB': ['PerfCurrentCount', 'PerfIntervalCount']}

    Source data warning: Recovered from a file whose complete MIB does not parse. The original assignment and definition are preserved. Registration and implementation details may be inaccurate; consult the original file. Other damaged or unresolved declarations are not established registrations.

    · Download SONET-MIB-rfc2558.txt

Historical records

Additional source information

Information from Circitor
sonetLineCurrentSESs OBJECT-TYPE
    SYNTAX  PerfCurrentCount
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
     "The counter associated with the number of
     Severely Errored Seconds
     encountered by a SONET/SDH Line in the current 15
     minute
     interval."
    ::= { sonetLineCurrentEntry 3 }
Information from Cisco SMIv1
sonetLineCurrentSESs OBJECT-TYPE
    SYNTAX PerfCurrentCount

    ACCESS read-only
    STATUS mandatory
    DESCRIPTION
        "The counter associated with the number of
        Severely Errored Seconds
        encountered by a SONET/SDH Line in the current 15
        minute
        interval."
    ::= { sonetLineCurrentEntry 3 }
Information from MIBdepot
sonetLineCurrentSESs OBJECT-TYPE
    SYNTAX  PerfCurrentCount
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
     "The counter associated with the number of
     Severely Errored Seconds
     encountered by a SONET/SDH Line in the current 15
     minute
     interval."
    ::= { sonetLineCurrentEntry 3 }
Information from Cisco
sonetLineCurrentSESs OBJECT-TYPE
       SYNTAX  PerfCurrentCount
       MAX-ACCESS  read-only
       STATUS  current
       DESCRIPTION
        "The counter associated with the number of
        Severely Errored Seconds
        encountered by a SONET/SDH Line in the current 15
        minute
        interval."
       ::= { sonetLineCurrentEntry 3 }

Registration

Registration authorities

First Registration Authority (inferred from ancestor 1.3.6)

Defense Communication Agency

Current Registration Authority (inferred from ancestor 1.3.6.1.2)

Internet Assigned Numbers Authority

Siblings (4)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.2.1.10.39.1.3.1.1.1 sonetLineCurrentStatus00 This variable indicates the
status of the interface.
The sonetLineCurrentStatus
is a bit map represented
as a sum, therefore,
it can…
1.3.6.1.2.1.10.39.1.3.1.1.2 sonetLineCurrentESs00 The counter associated with the number of Errored
Seconds encountered by a SONET/SDH
Line in the current 15 minute interval.
1.3.6.1.2.1.10.39.1.3.1.1.4 sonetLineCurrentCVs00 The counter associated with the number of Coding
Violations encountered by a
SONET/SDH Line in the current 15 minute interval.
1.3.6.1.2.1.10.39.1.3.1.1.5 sonetLineCurrentUASs00 The counter associated with the number of
Unavailable Seconds
encountered by a SONET/SDH Line in the current 15
minute
interval.