OID reference

historyControlInterval

1.3.6.1.2.1.16.2.1.1.5

Description

The interval in seconds over which the data is sampled for each bucket in the part of the media-specific table associated with this historyControlEntry. This interval can be set to any number of seconds between 1 and 3600 (1 hour). Because the counters in a bucket may overflow at their maximum value with no indication…

Full description and source information

Identification

Identifier and names

Parent
1.3.6.1.2.1.16.2.1.1 (historyControlEntry)
Node code
5
Node name
historyControlInterval
Category
SNMP management object
Numeric OID
1.3.6.1.2.1.16.2.1.1.5
URN notation
urn:oid:1.3.6.1.2.1.16.2.1.1.5
Type
OBJECT-TYPE
ASN.1, OID-IRI and named path variants
ASN.1 notation

{1 3 6 1 2 1 16 2 1 1 5}

  • {iso(1) identified-organization(3) dod(6) internet(1) mgmt(2) mib-2(1) rmon(16) history(2) historyControlTable(1) historyControlEntry(1) historyControlInterval(5)}
  • {iso(1) identified-organization(3) dod(6) internet(1) mgmt(2) mib(1) rmon(16) history(2) historyControlTable(1) historyControlEntry(1) historyControlInterval(5)}
  • {iso(1) identified-organization(3) dod(6) internet(1) mgmt(2) stdmib-2(1) rmon(16) history(2) historyControlTable(1) historyControlEntry(1) historyControlInterval(5)}
  • {iso(1) org(3) dod(6) internet(1) mgmt(2) mib-2(1) rmon(16) history(2) historyControlTable(1) historyControlEntry(1) historyControlInterval(5)}
  • {iso(1) org(3) dod(6) internet(1) mgmt(2) mib(1) rmon(16) history(2) historyControlTable(1) historyControlEntry(1) historyControlInterval(5)}
  • {iso(1) org(3) dod(6) internet(1) mgmt(2) stdmib-2(1) rmon(16) history(2) historyControlTable(1) historyControlEntry(1) historyControlInterval(5)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) mgmt(2) mib-2(1) rmon(16) history(2) historyControlTable(1) historyControlEntry(1) historyControlInterval(5)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) mgmt(2) mib(1) rmon(16) history(2) historyControlTable(1) historyControlEntry(1) historyControlInterval(5)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) mgmt(2) stdmib-2(1) rmon(16) history(2) historyControlTable(1) historyControlEntry(1) historyControlInterval(5)}
  • {iso(1) iso-organization(3) dod(6) internet(1) mgmt(2) mib-2(1) rmon(16) history(2) historyControlTable(1) historyControlEntry(1) historyControlInterval(5)}
  • {iso(1) iso-organization(3) dod(6) internet(1) mgmt(2) mib(1) rmon(16) history(2) historyControlTable(1) historyControlEntry(1) historyControlInterval(5)}
  • {iso(1) iso-organization(3) dod(6) internet(1) mgmt(2) stdmib-2(1) rmon(16) history(2) historyControlTable(1) historyControlEntry(1) historyControlInterval(5)}
OID-IRI notation
  • /1/3/6/1/2/1/16/2/1/1/5
  • /ISO/Identified-Organization/6/1/2/1/16/2/1/1/5
  • /ISO/3/6/1/2/1/16/2/1/1/5
Named path variants
  • /iso/identified-organization/dod/internet/mgmt/mib-2/rmon/history/historyControlTable/historyControlEntry/historyControlInterval
  • /iso/identified-organization/dod/internet/mgmt/mib/rmon/history/historyControlTable/historyControlEntry/historyControlInterval
  • /iso/identified-organization/dod/internet/mgmt/RFC1066-MIB-INTERPRETATION/rmon/history/historyControlTable/historyControlEntry/historyControlInterval
  • /iso/identified-organization/dod/internet/mgmt/stdmib-2/rmon/history/historyControlTable/historyControlEntry/historyControlInterval
  • /iso/org/dod/internet/mgmt/mib-2/rmon/history/historyControlTable/historyControlEntry/historyControlInterval
  • /iso/org/dod/internet/mgmt/mib/rmon/history/historyControlTable/historyControlEntry/historyControlInterval
  • /iso/org/dod/internet/mgmt/RFC1066-MIB-INTERPRETATION/rmon/history/historyControlTable/historyControlEntry/historyControlInterval
  • /iso/org/dod/internet/mgmt/stdmib-2/rmon/history/historyControlTable/historyControlEntry/historyControlInterval
  • /iso/iso-identified-organization/dod/internet/mgmt/mib-2/rmon/history/historyControlTable/historyControlEntry/historyControlInterval
  • /iso/iso-identified-organization/dod/internet/mgmt/mib/rmon/history/historyControlTable/historyControlEntry/historyControlInterval
  • /iso/iso-identified-organization/dod/internet/mgmt/RFC1066-MIB-INTERPRETATION/rmon/history/historyControlTable/historyControlEntry/historyControlInterval
  • /iso/iso-identified-organization/dod/internet/mgmt/stdmib-2/rmon/history/historyControlTable/historyControlEntry/historyControlInterval
  • /iso/iso-organization/dod/internet/mgmt/mib-2/rmon/history/historyControlTable/historyControlEntry/historyControlInterval
  • /iso/iso-organization/dod/internet/mgmt/mib/rmon/history/historyControlTable/historyControlEntry/historyControlInterval
  • /iso/iso-organization/dod/internet/mgmt/RFC1066-MIB-INTERPRETATION/rmon/history/historyControlTable/historyControlEntry/historyControlInterval
  • /iso/iso-organization/dod/internet/mgmt/stdmib-2/rmon/history/historyControlTable/historyControlEntry/historyControlInterval

SNMP properties

Value type
INTEGER, Integer32
Units
Seconds
Maximum access defined by MIB
read-write, read-create
Status in MIB
current, mandatory
Default value
1800

Definitions may combine these properties differently.

Compare 3 source variants

Variant 1 — MIBdepot

Value type
INTEGER
Maximum access defined by MIB
read-write
Status in MIB
current
Default value
1800
Allowed ranges
1–3600

Variant 2 — MIBdepot, Cisco SMIv1, and others

Value type
INTEGER
Maximum access defined by MIB
read-write
Status in MIB
mandatory
Default value
1800
Allowed ranges
1–3600

Variant 3 — Cisco

Value type
Integer32
Units
Seconds
Maximum access defined by MIB
read-create
Status in MIB
current
Default value
1800
Allowed ranges
1–3600

Using this OID with SNMP

At least one MIB declaration places this object in a table row. A value belongs to a row instance; its suffix depends on the row's INDEX or AUGMENTS definition.

In RFC1271-MIB, the row index historyControlIndex is declared as INTEGER. A non-negative index value is encoded as one numeric subidentifier. An instance has the form .1.3.6.1.2.1.16.2.1.1.5.<historyControlIndex>. Use an index value actually present on the device and permitted by its MIB. Other definitions can differ.

snmpwalk [connection options] DEVICE .1.3.6.1.2.1.16.2.1.1.5

Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.

Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.

Available source records contain 2 distinct definitions; some records may not include a definition.

Show 2 published definitions

historyControlInterval · unspecified

3.3.1.2.6 historyControlInterval(1.3.6.1.2.1.16.2.1.1.5)
定義
各サンプリングが行われる秒間隔を示す。この間隔は 1 から 3600 の間で設定が可能であ る。
実装
snmp‑server rmon‑history default‑entry enable 設定が有効な場合、30 秒と 1800 秒の エントリーが物理ポート数分作成される。

historyControlInterval · current

historyControlInterval OBJECT-TYPE
              SYNTAX INTEGER (1..3600)
              MAX-ACCESS read-write
              STATUS current
              DESCRIPTION
                  "The interval in seconds over which the data is
                  sampled for each bucket in the part of the
                  media-specific table associated with this
                  historyControlEntry.  This interval can
                  be set to any number of seconds between 1 and
                  3600 (1 hour).

                  Because the counters in a bucket may overflow at their
                  maximum value with no indication, a prudent manager
                  will take into account the possibility of overflow
                  in any of the associated counters.  It is important
                  to consider the minimum time in which any counter
                  could overflow on a particular media type and set
                  the historyControlInterval object to a value less
                  than this interval.  This is typically most
                  important for the 'octets' counter in any
                  media-specific table.  For example, on an Ethernet
                  network, the etherHistoryOctets counter could
                  overflow in about one hour at the Ethernet's maximum
                  utilization.

                  This object may not be modified if the associated
                  historyControlStatus object is equal to valid(1)."
              DEFVAL { 1800 }
              ::= { historyControlEntry 5 }

Meaning

Descriptions

8 unique

Identical descriptions are grouped. Different wording and device-specific notes are retained.

Description 1

The interval in seconds over which the data is sampled for each bucket in the part of the media-specific table associated with this historyControlEntry. This interval can be set to any number of seconds between 1 and 3600 (1 hour). Because the counters in a bucket may overflow at their maximum value with no indication, a prudent manager will take into account the possibility of overflow in any of the associated counters. It is important to consider the minimum time in which any counter could overflow on a particular media type and set the historyControlInterval object to a value less than this interval. This is typically most important for the 'octets' counter in any media-specific table. For example, on an Ethernet network, the etherHistoryOctets counter could overflow in about one hour at the Ethernet's maximum utilization. This object may not be modified if the associated historyControlStatus object is equal to valid(1).
Original text from OID Repository
historyControlInterval OBJECT-TYPE
SYNTAX INTEGER (1..3600)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The interval in seconds over which the data is
sampled for each bucket in the part of the
media-specific table associated with this
historyControlEntry. This interval can
be set to any number of seconds between 1 and
3600 (1 hour).
Because the counters in a bucket may overflow at their
maximum value with no indication, a prudent manager
will take into account the possibility of overflow
in any of the associated counters. It is important
to consider the minimum time in which any counter
could overflow on a particular media type and set
the historyControlInterval object to a value less
than this interval. This is typically most
important for the 'octets' counter in any
media-specific table. For example, on an Ethernet
network, the etherHistoryOctets counter could
overflow in about one hour at the Ethernet's maximum
utilization.
This object may not be modified if the associated
historyControlStatus object is equal to valid(1)."
DEFVAL { 1800 }
Sources for this description

MIBdepot

See 4 matching source records

OID Repository

View at oid-base.com
Automatically extracted from rfc1757

Circitor

Parsed from RMON-MIB.mib · RMON-MIB

Source file: Download RMON-MIB-1757.mib · Publisher's file

Source file: Download rfc1757.mib · Publisher's file

Source file: Download RMON-MIB.my · Publisher's file

Cisco SMIv1

Source file: Download RMON-MIB-V1SMI.my · Publisher's file

Description 2

The interval in seconds over which the data is
sampled for each bucket in the part of the
media-specific table associated with this
historyControl entry. This interval can
be set to any number of seconds between 1 and


3600 (1 hour).

Because the counters in a bucket may overflow at their
maximum value with no indication, a prudent manager
will take into account the possibility of overflow
in any of the associated counters. It is important
to consider the minimum time in which any counter
could overflow on a particular media type and set
the historyControlInterval object to a value less
than this interval. This is typically most
important for the 'octets' counter in any
media-specific table. For example, on an Ethernet
network, the etherHistoryOctets counter could overflow
in about one hour at the Ethernet's maximum
utilization.

This object may not be modified if the associated
historyControlStatus object is equal to valid(1).
Sources for this description

Description 3

The interval in seconds over which the data is sampled for each bucket in the part of the media-specific table associated with this historyControlEntry. This interval can be set to any number of seconds between 1 and 3600 (1 hour). Because the counters in a bucket may overflow at their maximum value with no indication, a prudent manager will take into account the possibility of overflow in any of the associated counters. It is important to consider the minimum time in which any counter could overflow on a particular media type and set the historyControlInterval object to a value less than this interval. This is typically most important for the 'octets' counter in any media-specific table. For example, on an Ethernet network, the etherHistoryOctets counter could overflow in about one hour at the Ethernet's maximum utilization. This object may not be modified if the associated historyControlStatus object is equal to valid(1).

Implementation notes: The actually supported value range is 5..3600

Sources for this description

Huawei official enterprise MIB Query and object descriptions

See 4 matching source records

Description 4

Sampling interval in seconds.

Sources for this description

H3C official MIB documentation and object descriptions

See 1 matching source record

Description 5

The interval in seconds over which the data is sampled for each bucket in the part of the media-specific table associated with this historyControlEntry. This interval can be set to any number of seconds between 1 and 3600 (1 hour). Because the counters in a bucket may overflow at their maximum value with no indication, a prudent manager will take into account the possibility of overflow in any of the associated counters. It is important to consider the minimum time in which any counter could overflow on a particular media type and set the historyControlInterval object to a value less than this interval. This is typically most important for the 'octets' counter in any media-specific table. For example, on an Ethernet network, the etherHistoryOctets counter could overflow in about one hour at the Ethernet's maximum utilization. This object may not be modified if the associated historyControlStatus object is equal to valid(1).

Implementation notes: The actually supported value range is 5-3600.

Sources for this description

Huawei official enterprise MIB Query and object descriptions

See 4 matching source records

Description 6

The value of this object identifies the interval of collecting statistics and sampling for the media statistics history table. Value range: 1 to 3600 seconds

Implementation notes: Currently, the value range from 5 to 3600 seconds.

Sources for this description

Huawei official enterprise MIB Query and object descriptions

See 1 matching source record

Description 7

The interval in seconds over which the data is sampled for each bucket in the part of the media-specific table associated with this historyControlEntry. This interval can be set to any number of seconds between 1 and 3600 (1 hour). Because the counters in a bucket may overflow at their maximum value with no indication, a prudent manager will take into account the possibility of overflow in any of the associated counters. It is important to consider the minimum time in which any counter could overflow on a particular media type and set the historyControlInterval object to a value less than this interval. This is typically most important for the 'octets' counter in any media-specific table. For example, on an Ethernet network, the etherHistoryOctets counter could overflow in about one hour at the Ethernet's maximum utilization. This object may not be modified if the associated historyControlStatus object is equal to valid(1).

Implementation notes: The actually supported value range is 5..3600 This object is implemented as defined in the corresponding MIB files.

Sources for this description

Huawei official enterprise MIB Query and object descriptions

See 4 matching source records

Description 8

Definition: 各サンプリングが行われる秒間隔を示す。この間隔は 1 から 3600 の間で設定が可能であ る。 AEOS 8.45 implementation: snmp‑server rmon‑history default‑entry enable 設定が有効な場合、30 秒と 1800 秒の エントリーが物理ポート数分作成される。

Sources for this description

APRESIA AEOS 8.45 official MIB implementation manual

See 1 matching source record

Evidence

Source records

7 records

Matching descriptions are grouped; representative source files are shown for each definition.

Records for description 1, 3, 5, 7Huawei official enterprise MIB Query and object descriptions, MIBdepot4 records · 5 sources

Description 1 · Description 3 · Description 5 · Description 7

historyControlInterval · unspecifiedHuawei official enterprise MIB Query and object descriptions1 source
historyControlInterval · unspecifiedHuawei official enterprise MIB Query and object descriptions1 source
historyControlInterval · unspecifiedHuawei official enterprise MIB Query and object descriptions1 source

Status in source: unspecified.

Names: historyControlInterval

Technical details
{
  "syntax": "Integer32{(1,3600)}",
  "max_access": "read-create",
  "object_class": "table column",
  "implementation_notes": "The actually supported value range is 5..3600 This object is implemented as defined in the corresponding MIB files."
}
historyControlInterval · currentMIBdepot2 sources

Status in source: current.

Names: historyControlInterval

Records for description 4H3C official MIB documentation and object descriptions1 record · 32 sources
Records for description 6Huawei official enterprise MIB Query and object descriptions1 record · 1 source
Records for description 8APRESIA AEOS 8.45 official MIB implementation manual1 record · 1 source

Description 8

historyControlInterval · unspecifiedAPRESIA AEOS 8.45 official MIB implementation manual1 source

Status in source: unspecified.

Names: historyControlInterval

Technical details
{
  "definition": [
    "3",
    ".",
    "3",
    ".",
    "1",
    ".",
    "2",
    ".",
    "6",
    "historyControlInterval",
    "(",
    "1",
    ".",
    "3",
    ".",
    "6",
    ".",
    "1",
    ".",
    "2",
    ".",
    "1",
    ".",
    "16",
    ".",
    "2",
    ".",
    "1",
    ".",
    "1",
    ".",
    "5",
    ")",
    "定",
    "義",
    "各",
    "サ",
    "ン",
    "プ",
    "リ",
    "ン",
    "グ",
    "が",
    "行",
    "わ",
    "れ",
    "る",
    "秒",
    "間",
    "隔",
    "を",
    "示",
    "す",
    "。",
    "こ",
    "の",
    "間",
    "隔",
    "は",
    "1",
    "か",
    "ら",
    "3600",
    "の",
    "間",
    "で",
    "設",
    "定",
    "が",
    "可",
    "能",
    "で",
    "あ",
    "る",
    "。",
    "実",
    "装",
    "snmp",
    "‑",
    "server",
    "rmon",
    "‑",
    "history",
    "default",
    "‑",
    "entry",
    "enable",
    "設",
    "定",
    "が",
    "有",
    "効",
    "な",
    "場",
    "合",
    "、",
    "30",
    "秒",
    "と",
    "1800",
    "秒",
    "の",
    "エ",
    "ン",
    "ト",
    "リ",
    "ー",
    "が",
    "物",
    "理",
    "ポ",
    "ー",
    "ト",
    "数",
    "分",
    "作",
    "成",
    "さ",
    "れ",
    "る",
    "。"
  ]
}

Historical records

Additional source information

Information from Circitor
historyControlInterval OBJECT-TYPE
              SYNTAX INTEGER (1..3600)
              ACCESS read-write
              STATUS mandatory
              DESCRIPTION
                  "The interval in seconds over which the data is
                  sampled for each bucket in the part of the
                  media-specific table associated with this
                  historyControlEntry.  This interval can
                  be set to any number of seconds between 1 and
                  3600 (1 hour).

                  Because the counters in a bucket may overflow at their
                  maximum value with no indication, a prudent manager
                  will take into account the possibility of overflow
                  in any of the associated counters.  It is important
                  to consider the minimum time in which any counter
                  could overflow on a particular media type and set
                  the historyControlInterval object to a value less





                  than this interval.  This is typically most
                  important for the 'octets' counter in any
                  media-specific table.  For example, on an Ethernet
                  network, the etherHistoryOctets counter could
                  overflow in about one hour at the Ethernet's maximum
                  utilization.

                  This object may not be modified if the associated
                  historyControlStatus object is equal to valid(1)."
              DEFVAL { 1800 }
              ::= { historyControlEntry 5 }
Information from Cisco SMIv1
historyControlInterval OBJECT-TYPE
    SYNTAX INTEGER(1..3600)


    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
        "The interval in seconds over which the data is
        sampled for each bucket in the part of the
        media-specific table associated with this
        historyControlEntry.  This interval can
        be set to any number of seconds between 1 and
        3600 (1 hour).
        
        Because the counters in a bucket may overflow at their
        maximum value with no indication, a prudent manager will
        take into account the possibility of overflow in any of
        the associated counters.  It is important to consider the
        minimum time in which any counter could overflow on a
        particular media type and set the historyControlInterval
        object to a value less than this interval.  This is
        typically most important for the 'octets' counter in any
        media-specific table.  For example, on an Ethernet
        network, the etherHistoryOctets counter could overflow
        in about one hour at the Ethernet's maximum
        utilization.
        
        This object may not be modified if the associated
        historyControlStatus object is equal to valid(1)."
    DEFVAL { 1800 }
    ::= { historyControlEntry 5 }
Information from MIBdepot
historyControlInterval OBJECT-TYPE
              SYNTAX INTEGER (1..3600)
              ACCESS read-write
              STATUS mandatory
              DESCRIPTION
                  "The interval in seconds over which the data is
                  sampled for each bucket in the part of the
                  media-specific table associated with this
                  historyControl entry.  This interval can
                  be set to any number of seconds between 1 and


                  3600 (1 hour).

                  Because the counters in a bucket may overflow at their
                  maximum value with no indication, a prudent manager
                  will take into account the possibility of overflow
                  in any of the associated counters.  It is important
                  to consider the minimum time in which any counter
                  could overflow on a particular media type and set
                  the historyControlInterval object to a value less
                  than this interval.  This is typically most
                  important for the 'octets' counter in any
                  media-specific table.  For example, on an Ethernet
                  network, the etherHistoryOctets counter could overflow
                  in about one hour at the Ethernet's maximum
                  utilization.

                  This object may not be modified if the associated
                  historyControlStatus object is equal to valid(1)."
              DEFVAL { 1800 }
              ::= { historyControlEntry 5 }
Information from Cisco
historyControlInterval OBJECT-TYPE
     SYNTAX     Integer32 (1..3600)
     UNITS      "Seconds"
     MAX-ACCESS read-create
     STATUS     current
     DESCRIPTION
         "The interval in seconds over which the data is
         sampled for each bucket in the part of the
         media-specific table associated with this
         historyControlEntry.  This interval can
         be set to any number of seconds between 1 and
         3600 (1 hour).

         Because the counters in a bucket may overflow at their
         maximum value with no indication, a prudent manager will
         take into account the possibility of overflow in any of
         the associated counters.  It is important to consider the
         minimum time in which any counter could overflow on a
         particular media type and set the historyControlInterval
         object to a value less than this interval.  This is
         typically most important for the 'octets' counter in any
         media-specific table.  For example, on an Ethernet
         network, the etherHistoryOctets counter could overflow
         in about one hour at the Ethernet's maximum
         utilization.

         This object may not be modified if the associated
         historyControlStatus object is equal to valid(1)."
     DEFVAL { 1800 }
     ::= { historyControlEntry 5 }

Registration

Registration authorities

First Registration Authority (inferred from ancestor 1.3.6)

Defense Communication Agency

Current Registration Authority (inferred from ancestor 1.3.6.1.2)

Internet Assigned Numbers Authority

Siblings (6)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.2.1.16.2.1.1.1 historyControlIndex00 An index that uniquely identifies an entry in the
historyControl table. Each such entry defines a
set of samples at a particular…
1.3.6.1.2.1.16.2.1.1.2 historyControlDataSource00 This object identifies the source of the data for
which historical data was collected and
placed in a media-specific table on beh…
1.3.6.1.2.1.16.2.1.1.3 historyControlBucketsRequested00 The requested number of discrete time intervals
over which data is to be saved in the part of the
media-specific table associated…
1.3.6.1.2.1.16.2.1.1.4 historyControlBucketsGranted00 The number of discrete sampling intervals
over which data shall be saved in the part of
the media-specific table associated with …
1.3.6.1.2.1.16.2.1.1.6 historyControlOwner00 The entity that configured this entry and is
therefore using the resources assigned to it.
1.3.6.1.2.1.16.2.1.1.7 historyControlStatus00 The status of this historyControl entry.

Each instance of the media-specific table associated
with this historyControlEntry will …