The MIB module is for Advantech automation devices common entities. Copyright (C) 2015 Advantech Automation Group.
Sources for this description
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
OID reference
1.3.6.1.4.1.10297.100
The MIB module is for Advantech automation devices common entities. Copyright (C) 2015 Advantech Automation Group.
Identification
{1 3 6 1 4 1 10297 100}
The displayed source records contain one distinct definition. Compare its source records.
advantechCommonMIB MODULE-IDENTITY
LAST-UPDATED "201501060000Z"
ORGANIZATION "Advantech eAutomation Group"
CONTACT-INFO
" Advantech eAutomation Embedded Software
E-mail: support@advantech.com
Campion.Kang@advantech.com.tw"
DESCRIPTION
"The MIB module is for Advantech automation devices common entities.
Copyright (C) 2015 Advantech Automation Group.
"
-- * Revision history
REVISION "201305250000Z"
DESCRIPTION
"Initial version of the Advantech Common MIB. "
REVISION "201308280000Z"
DESCRIPTION
"Fixed the worng id of psIRQ, psState,
psModuleType and psModulePorts in pciConfigObj "
REVISION "201308290000Z"
DESCRIPTION
"Update the Size of psBaseAddress to 32."
REVISION "201309060000Z"
DESCRIPTION
"1. Update the Size of psBaseAddress to 80(8x10).
2. Add psLength (pciSlotEntry 15).
3. Fixed wrong snmpTrapVersion enumeration from enable(1),
disabled(2) to v1(1), v2c(2), v3(3)."
REVISION "201410130000Z"
DESCRIPTION
"Add DateAndTime specification in the description of the oid
which is DateAndTime type."
REVISION "201410220000Z"
DESCRIPTION
"To support ManageEngine MibBrowser Free Tool"
REVISION "201501060000Z"
DESCRIPTION
"Change psDisplayName, psDescr, psManufacturer, psLocation to SnmpAdminString
to support UTF-8 string."
::= { advantech 100 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
The MIB module is for Advantech automation devices common entities. Copyright (C) 2015 Advantech Automation Group.
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: unspecified.
Names: advantechCommonMIB
{
"smi_kind": "MODULE-IDENTITY",
"definition": [
"advantechCommonMIB",
"MODULE-IDENTITY",
"LAST-UPDATED",
[
"literal",
"223230313530313036303030305a22"
],
"ORGANIZATION",
"\"Advantech eAutomation Group\"",
"CONTACT-INFO",
"\" Advantech eAutomation Embedded Software E-mail: support@advantech.com Campion.Kang@advantech.com.tw\"",
"DESCRIPTION",
"\"The MIB module is for Advantech automation devices common entities. Copyright (C) 2015 Advantech Automation Group. \"",
"REVISION",
[
"literal",
"223230313330353235303030305a22"
],
"DESCRIPTION",
"\"Initial version of the Advantech Common MIB. \"",
"REVISION",
[
"literal",
"223230313330383238303030305a22"
],
"DESCRIPTION",
"\"Fixed the worng id of psIRQ, psState, psModuleType and psModulePorts in pciConfigObj \"",
"REVISION",
[
"literal",
"223230313330383239303030305a22"
],
"DESCRIPTION",
"\"Update the Size of psBaseAddress to 32.\"",
"REVISION",
[
"literal",
"223230313330393036303030305a22"
],
"DESCRIPTION",
"\"1. Update the Size of psBaseAddress to 80(8x10). 2. Add psLength (pciSlotEntry 15). 3. Fixed wrong snmpTrapVersion enumeration from enable(1), disabled(2) to v1(1), v2c(2), v3(3).\"",
"REVISION",
[
"literal",
"223230313431303133303030305a22"
],
"DESCRIPTION",
"\"Add DateAndTime specification in the description of the oid which is DateAndTime type.\"",
"REVISION",
[
"literal",
"223230313431303232303030305a22"
],
"DESCRIPTION",
"\"To support ManageEngine MibBrowser Free Tool\"",
"REVISION",
[
"literal",
"223230313530313036303030305a22"
],
"DESCRIPTION",
"\"Change psDisplayName, psDescr, psManufacturer, psLocation to SnmpAdminString to support UTF-8 string.\"",
"::=",
"{",
"advantech",
"100",
"}"
],
"syntax_tree": [
[
"LAST-UPDATED",
"201501060000Z"
],
[
"ORGANIZATION",
"Advantech eAutomation Group"
],
[
"CONTACT-INFO",
"Advantech eAutomation Embedded Software E-mail: support@advantech.com Campion.Kang@advantech.com.tw"
],
[
"DESCRIPTION",
"The MIB module is for Advantech automation devices common entities. Copyright (C) 2015 Advantech Automation Group."
],
[
"Revisions",
[
[
"201305250000Z",
[
"DESCRIPTION",
"Initial version of the Advantech Common MIB."
]
],
[
"201308280000Z",
[
"DESCRIPTION",
"Fixed the worng id of psIRQ, psState, psModuleType and psModulePorts in pciConfigObj"
]
],
[
"201308290000Z",
[
"DESCRIPTION",
"Update the Size of psBaseAddress to 32."
]
],
[
"201309060000Z",
[
"DESCRIPTION",
"1. Update the Size of psBaseAddress to 80(8x10). 2. Add psLength (pciSlotEntry 15). 3. Fixed wrong snmpTrapVersion enumeration from enable(1), disabled(2) to v1(1), v2c(2), v3(3)."
]
],
[
"201410130000Z",
[
"DESCRIPTION",
"Add DateAndTime specification in the description of the oid which is DateAndTime type."
]
],
[
"201410220000Z",
[
"DESCRIPTION",
"To support ManageEngine MibBrowser Free Tool"
]
],
[
"201501060000Z",
[
"DESCRIPTION",
"Change psDisplayName, psDescr, psManufacturer, psLocation to SnmpAdminString to support UTF-8 string."
]
]
]
]
]
}Vendor MIB copy from the LibreNMS archive.
Module: ADVANTECH-COMMON-MIB
See published definition above
{'SNMPv2-SMI': ['MODULE-IDENTITY', 'enterprises', 'OBJECT-TYPE', 'Integer32', 'IpAddress', 'TimeTicks'], 'SNMPv2-CONF': ['OBJECT-GROUP'], 'SNMPv2-TC-v1': ['DisplayString', 'DateAndTime'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}Related source files and packages:
Same file in Observium Community.
Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.10297.100.1 | atSystem | 8 | 8 | |
| 1.3.6.1.4.1.10297.100.2 | atMgmt | 1 | 10 | |
| 1.3.6.1.4.1.10297.100.3 | atPciConfig | 1 | 23 |
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.10297.202 | aSwitchMIB | 1 | 1331 |