OID reference

dot3StatsSymbolErrors

1.3.6.1.4.1.10297.202.7000.1.3.1.1.23

Description

For an interface operating at 100 Mb/s, the number of times there was an invalid data symbol when a valid carrier was present. For an interface operating in half-duplex mode at 1000 Mb/s, the number of times the receiving media is non-idle (a carrier event) for a period of time equal to or greater than slotTime, and d…

Full description and source information

Identification

Identifier and names

Parent
1.3.6.1.4.1.10297.202.7000.1.3.1.1 (portStatisticEntry)
Node code
23
Node name
dot3StatsSymbolErrors
Category
SNMP management object
Numeric OID
1.3.6.1.4.1.10297.202.7000.1.3.1.1.23
URN notation
urn:oid:1.3.6.1.4.1.10297.202.7000.1.3.1.1.23
ASN.1, OID-IRI and named path variants
ASN.1 notation

{1 3 6 1 4 1 10297 202 7000 1 3 1 1 23}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) advantech(10297) aSwitchMIB(202) proneer(7000) monitoring(1) portMonitoring(3) portStatisticTable(1) portStatisticEntry(1) dot3StatsSymbolErrors(23)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) advantech(10297) aSwitchMIB(202) proneer(7000) monitoring(1) portMonitoring(3) portStatisticTable(1) portStatisticEntry(1) dot3StatsSymbolErrors(23)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) advantech(10297) aSwitchMIB(202) proneer(7000) monitoring(1) portMonitoring(3) portStatisticTable(1) portStatisticEntry(1) dot3StatsSymbolErrors(23)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) advantech(10297) aSwitchMIB(202) proneer(7000) monitoring(1) portMonitoring(3) portStatisticTable(1) portStatisticEntry(1) dot3StatsSymbolErrors(23)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) advantech(10297) aSwitchMIB(202) proneer(7000) monitoring(1) portMonitoring(3) portStatisticTable(1) portStatisticEntry(1) dot3StatsSymbolErrors(23)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) advantech(10297) aSwitchMIB(202) proneer(7000) monitoring(1) portMonitoring(3) portStatisticTable(1) portStatisticEntry(1) dot3StatsSymbolErrors(23)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) advantech(10297) aSwitchMIB(202) proneer(7000) monitoring(1) portMonitoring(3) portStatisticTable(1) portStatisticEntry(1) dot3StatsSymbolErrors(23)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) advantech(10297) aSwitchMIB(202) proneer(7000) monitoring(1) portMonitoring(3) portStatisticTable(1) portStatisticEntry(1) dot3StatsSymbolErrors(23)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprise(1) advantech(10297) aSwitchMIB(202) proneer(7000) monitoring(1) portMonitoring(3) portStatisticTable(1) portStatisticEntry(1) dot3StatsSymbolErrors(23)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) advantech(10297) aSwitchMIB(202) proneer(7000) monitoring(1) portMonitoring(3) portStatisticTable(1) portStatisticEntry(1) dot3StatsSymbolErrors(23)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) advantech(10297) aSwitchMIB(202) proneer(7000) monitoring(1) portMonitoring(3) portStatisticTable(1) portStatisticEntry(1) dot3StatsSymbolErrors(23)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) advantech(10297) aSwitchMIB(202) proneer(7000) monitoring(1) portMonitoring(3) portStatisticTable(1) portStatisticEntry(1) dot3StatsSymbolErrors(23)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) enterprise(1) advantech(10297) aSwitchMIB(202) proneer(7000) monitoring(1) portMonitoring(3) portStatisticTable(1) portStatisticEntry(1) dot3StatsSymbolErrors(23)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) enterprises(1) advantech(10297) aSwitchMIB(202) proneer(7000) monitoring(1) portMonitoring(3) portStatisticTable(1) portStatisticEntry(1) dot3StatsSymbolErrors(23)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) advantech(10297) aSwitchMIB(202) proneer(7000) monitoring(1) portMonitoring(3) portStatisticTable(1) portStatisticEntry(1) dot3StatsSymbolErrors(23)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) vendor-objects(1) advantech(10297) aSwitchMIB(202) proneer(7000) monitoring(1) portMonitoring(3) portStatisticTable(1) portStatisticEntry(1) dot3StatsSymbolErrors(23)}
OID-IRI notation
  • /1/3/6/1/4/1/10297/202/7000/1/3/1/1/23
  • /ISO/Identified-Organization/6/1/4/1/10297/202/7000/1/3/1/1/23
  • /ISO/3/6/1/4/1/10297/202/7000/1/3/1/1/23
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/10297/aSwitchMIB/proneer/monitoring/portMonitoring/portStatisticTable/portStatisticEntry/dot3StatsSymbolErrors
  • /iso/identified-organization/dod/internet/private/enterprise/advantech/aSwitchMIB/proneer/monitoring/portMonitoring/portStatisticTable/portStatisticEntry/dot3StatsSymbolErrors
  • /iso/identified-organization/dod/internet/private/enterprises/10297/aSwitchMIB/proneer/monitoring/portMonitoring/portStatisticTable/portStatisticEntry/dot3StatsSymbolErrors
  • /iso/identified-organization/dod/internet/private/enterprises/advantech/aSwitchMIB/proneer/monitoring/portMonitoring/portStatisticTable/portStatisticEntry/dot3StatsSymbolErrors
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/10297/aSwitchMIB/proneer/monitoring/portMonitoring/portStatisticTable/portStatisticEntry/dot3StatsSymbolErrors
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/advantech/aSwitchMIB/proneer/monitoring/portMonitoring/portStatisticTable/portStatisticEntry/dot3StatsSymbolErrors
  • /iso/identified-organization/dod/internet/private/vendor-objects/10297/aSwitchMIB/proneer/monitoring/portMonitoring/portStatisticTable/portStatisticEntry/dot3StatsSymbolErrors
  • /iso/identified-organization/dod/internet/private/vendor-objects/advantech/aSwitchMIB/proneer/monitoring/portMonitoring/portStatisticTable/portStatisticEntry/dot3StatsSymbolErrors
  • /iso/org/dod/internet/private/enterprise/10297/aSwitchMIB/proneer/monitoring/portMonitoring/portStatisticTable/portStatisticEntry/dot3StatsSymbolErrors
  • /iso/org/dod/internet/private/enterprise/advantech/aSwitchMIB/proneer/monitoring/portMonitoring/portStatisticTable/portStatisticEntry/dot3StatsSymbolErrors
  • /iso/org/dod/internet/private/enterprises/10297/aSwitchMIB/proneer/monitoring/portMonitoring/portStatisticTable/portStatisticEntry/dot3StatsSymbolErrors
  • /iso/org/dod/internet/private/enterprises/advantech/aSwitchMIB/proneer/monitoring/portMonitoring/portStatisticTable/portStatisticEntry/dot3StatsSymbolErrors
  • /iso/org/dod/internet/private/ldap-enterprise/10297/aSwitchMIB/proneer/monitoring/portMonitoring/portStatisticTable/portStatisticEntry/dot3StatsSymbolErrors
  • /iso/org/dod/internet/private/ldap-enterprise/advantech/aSwitchMIB/proneer/monitoring/portMonitoring/portStatisticTable/portStatisticEntry/dot3StatsSymbolErrors
  • /iso/org/dod/internet/private/vendor-objects/10297/aSwitchMIB/proneer/monitoring/portMonitoring/portStatisticTable/portStatisticEntry/dot3StatsSymbolErrors
  • /iso/org/dod/internet/private/vendor-objects/advantech/aSwitchMIB/proneer/monitoring/portMonitoring/portStatisticTable/portStatisticEntry/dot3StatsSymbolErrors
  • Additional combinations skipped.

SNMP properties

Value type
Integer32
Maximum access defined by MIB
read-only
Status in MIB
current

Using this OID with SNMP

At least one MIB declaration places this object in a table row. A value belongs to a row instance; its suffix depends on the row's INDEX or AUGMENTS definition.

In ADVANTECH-EKI-PRONEER-MIB, the row index portStatisticIndex is declared as Integer32. A non-negative index value is encoded as one numeric subidentifier. An instance has the form .1.3.6.1.4.1.10297.202.7000.1.3.1.1.23.<portStatisticIndex>. Use an index value actually present on the device and permitted by its MIB. Other definitions can differ.

snmpwalk [connection options] DEVICE .1.3.6.1.4.1.10297.202.7000.1.3.1.1.23

Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.

Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.

The displayed source records contain one distinct definition. Compare its source records.

dot3StatsSymbolErrors OBJECT-TYPE
		    SYNTAX  	Integer32
		    MAX-ACCESS  read-only
		    STATUS  	current
		    DESCRIPTION	"For an interface operating at 100 Mb/s, the
					 	number of times there was an invalid data symbol
					 	when a valid carrier was present.
					 	
					 	For an interface operating in half-duplex mode
					 	at 1000 Mb/s, the number of times the receiving
					 	media is non-idle (a carrier event) for a period
					 	of time equal to or greater than slotTime, and
					 	during which there was at least one occurrence
					 	of an event that causes the PHY to indicate
					 	'Data reception error' or 'carrier extend error'
					 	on the GMII.
					 	
					 	For an interface operating in full-duplex mode
					 	at 1000 Mb/s, the number of times the receiving
					 	media is non-idle (a carrier event) for a period
					 	of time equal to or greater than minFrameSize,
					 	and during which there was at least one
					 	occurrence of an event that causes the PHY to
					 	indicate 'Data reception error' on the GMII.
					 	
					 	For an interface operating at 10 Gb/s, the
					 	number of times the receiving media is non-idle
					 	(a carrier event) for a period of time equal to
					 	or greater than minFrameSize, and during which
					 	there was at least one occurrence of an event
					 	that causes the PHY to indicate 'Receive Error'
					 	on the XGMII.
					 	
					 	The count represented by an instance of this
					 	object is incremented at most once per carrier
					 	event, even if multiple symbol errors occur
					 	during the carrier event.  This count does
					 	not increment if a collision is present.
					 	
					 	This counter does not increment when the
					 	interface is operating at 10 Mb/s.
					 	
					 	For interfaces operating at 10 Gb/s, this
					 	counter can roll over in less than 5 minutes if
					 	it is incrementing at its maximum rate.  Since
					 	that amount of time could be less than a
					 	management station's poll cycle time, in order
					 	to avoid a loss of information, a management
					 	station is advised to poll the
					 	dot3HCStatsSymbolErrors object for 10 Gb/s
					 	or faster interfaces.
					 	
					 	Discontinuities in the value of this counter can
					 	occur at re-initialization of the management
					 	system, and at other times as indicated by the
					 	value of ifCounterDiscontinuityTime."
		    ::= { portStatisticEntry 23 }

Meaning

Descriptions

1 unique

Identical descriptions are grouped. Different wording and device-specific notes are retained.

For an interface operating at 100 Mb/s, the number of times there was an invalid data symbol when a valid carrier was present. For an interface operating in half-duplex mode at 1000 Mb/s, the number of times the receiving media is non-idle (a carrier event) for a period of time equal to or greater than slotTime, and during which there was at least one occurrence of an event that causes the PHY to indicate 'Data reception error' or 'carrier extend error' on the GMII. For an interface operating in full-duplex mode at 1000 Mb/s, the number of times the receiving media is non-idle (a carrier event) for a period of time equal to or greater than minFrameSize, and during which there was at least one occurrence of an event that causes the PHY to indicate 'Data reception error' on the GMII. For an interface operating at 10 Gb/s, the number of times the receiving media is non-idle (a carrier event) for a period of time equal to or greater than minFrameSize, and during which there was at least one occurrence of an event that causes the PHY to indicate 'Receive Error' on the XGMII. The count represented by an instance of this object is incremented at most once per carrier event, even if multiple symbol errors occur during the carrier event. This count does not increment if a collision is present. This counter does not increment when the interface is operating at 10 Mb/s. For interfaces operating at 10 Gb/s, this counter can roll over in less than 5 minutes if it is incrementing at its maximum rate. Since that amount of time could be less than a management station's poll cycle time, in order to avoid a loss of information, a management station is advised to poll the dot3HCStatsSymbolErrors object for 10 Gb/s or faster interfaces. Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime.

Sources for this description

Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

See 1 matching source record

Evidence

Source records

1 records

Matching descriptions are grouped; open a group to compare definitions and supporting files.

Records for description 1Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 record · 1 source

Description 1

dot3StatsSymbolErrors · currentMultiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 source

Status in source: current.

Names: dot3StatsSymbolErrors

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "dot3StatsSymbolErrors",
    "OBJECT-TYPE",
    "SYNTAX",
    "Integer32",
    "MAX-ACCESS",
    "read-only",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"For an interface operating at 100 Mb/s, the number of times there was an invalid data symbol when a valid carrier was present. For an interface operating in half-duplex mode at 1000 Mb/s, the number of times the receiving media is non-idle (a carrier event) for a period of time equal to or greater than slotTime, and during which there was at least one occurrence of an event that causes the PHY to indicate 'Data reception error' or 'carrier extend error' on the GMII. For an interface operating in full-duplex mode at 1000 Mb/s, the number of times the receiving media is non-idle (a carrier event) for a period of time equal to or greater than minFrameSize, and during which there was at least one occurrence of an event that causes the PHY to indicate 'Data reception error' on the GMII. For an interface operating at 10 Gb/s, the number of times the receiving media is non-idle (a carrier event) for a period of time equal to or greater than minFrameSize, and during which there was at least one occurrence of an event that causes the PHY to indicate 'Receive Error' on the XGMII. The count represented by an instance of this object is incremented at most once per carrier event, even if multiple symbol errors occur during the carrier event. This count does not increment if a collision is present. This counter does not increment when the interface is operating at 10 Mb/s. For interfaces operating at 10 Gb/s, this counter can roll over in less than 5 minutes if it is incrementing at its maximum rate. Since that amount of time could be less than a management station's poll cycle time, in order to avoid a loss of information, a management station is advised to poll the dot3HCStatsSymbolErrors object for 10 Gb/s or faster interfaces. Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime.\"",
    "::=",
    "{",
    "portStatisticEntry",
    "23",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "Integer32"
    ],
    null,
    [
      "MaxAccessPart",
      "read-only"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "For an interface operating at 100 Mb/s, the number of times there was an invalid data symbol when a valid carrier was present. For an interface operating in half-duplex mode at 1000 Mb/s, the number of times the receiving media is non-idle (a carrier event) for a period of time equal to or greater than slotTime, and during which there was at least one occurrence of an event that causes the PHY to indicate 'Data reception error' or 'carrier extend error' on the GMII. For an interface operating in full-duplex mode at 1000 Mb/s, the number of times the receiving media is non-idle (a carrier event) for a period of time equal to or greater than minFrameSize, and during which there was at least one occurrence of an event that causes the PHY to indicate 'Data reception error' on the GMII. For an interface operating at 10 Gb/s, the number of times the receiving media is non-idle (a carrier event) for a period of time equal to or greater than minFrameSize, and during which there was at least one occurrence of an event that causes the PHY to indicate 'Receive Error' on the XGMII. The count represented by an instance of this object is incremented at most once per carrier event, even if multiple symbol errors occur during the carrier event. This count does not increment if a collision is present. This counter does not increment when the interface is operating at 10 Mb/s. For interfaces operating at 10 Gb/s, this counter can roll over in less than 5 minutes if it is incrementing at its maximum rate. Since that amount of time could be less than a management station's poll cycle time, in order to avoid a loss of information, a management station is advised to poll the dot3HCStatsSymbolErrors object for 10 Gb/s or faster interfaces. Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime."
    ],
    null,
    null,
    null,
    null
  ]
}

Registration

Registration authorities

First Registration Authority (inferred from ancestor 1.3.6.1.4.1.10297)

Wei Franz

Siblings (25)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.10297.202.7000.1.3.1.1.1 portStatisticIndex00
1.3.6.1.4.1.10297.202.7000.1.3.1.1.2 portCounterClear00
1.3.6.1.4.1.10297.202.7000.1.3.1.1.3 ifInOctets00
1.3.6.1.4.1.10297.202.7000.1.3.1.1.4 ifInUcastPkts00
1.3.6.1.4.1.10297.202.7000.1.3.1.1.5 ifInNUcastPkts00
1.3.6.1.4.1.10297.202.7000.1.3.1.1.6 ifInDiscards00
1.3.6.1.4.1.10297.202.7000.1.3.1.1.7 ifOutOctets00
1.3.6.1.4.1.10297.202.7000.1.3.1.1.8 ifOutUcastPkts00
1.3.6.1.4.1.10297.202.7000.1.3.1.1.9 ifOutNUcastPkts00
1.3.6.1.4.1.10297.202.7000.1.3.1.1.10 ifOutDiscards00
1.3.6.1.4.1.10297.202.7000.1.3.1.1.11 ifInMulticastPkts00
1.3.6.1.4.1.10297.202.7000.1.3.1.1.12 ifInBroadcastPkts00
1.3.6.1.4.1.10297.202.7000.1.3.1.1.13 ifOutMulticastPkts00
1.3.6.1.4.1.10297.202.7000.1.3.1.1.14 ifOutBroadcastPkts00
1.3.6.1.4.1.10297.202.7000.1.3.1.1.15 dot3StatsAlignmentErrors00
1.3.6.1.4.1.10297.202.7000.1.3.1.1.16 dot3StatsFCSErrors00
1.3.6.1.4.1.10297.202.7000.1.3.1.1.17 dot3StatsSingleCollisionFrames00
1.3.6.1.4.1.10297.202.7000.1.3.1.1.18 dot3StatsMultipleCollisionFrames00
1.3.6.1.4.1.10297.202.7000.1.3.1.1.19 dot3StatsDeferredTransmissions00
1.3.6.1.4.1.10297.202.7000.1.3.1.1.20 dot3StatsLateCollisions00
1.3.6.1.4.1.10297.202.7000.1.3.1.1.21 dot3StatsExcessiveCollisions00
1.3.6.1.4.1.10297.202.7000.1.3.1.1.22 dot3StatsFrameTooLongs00
1.3.6.1.4.1.10297.202.7000.1.3.1.1.24 dot3ControlInUnknownOpcodes00
1.3.6.1.4.1.10297.202.7000.1.3.1.1.25 dot3InPauseFrames00
1.3.6.1.4.1.10297.202.7000.1.3.1.1.26 dot3OutPauseFrames00