Status in source: current.
Names: communityString
Technical details
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"communityString",
"OBJECT-TYPE",
"SYNTAX",
"DisplayString",
"MAX-ACCESS",
"read-write",
"STATUS",
"current",
"DESCRIPTION",
"\"A unique textual string that can be used by a SNMP manager as community string. It can be also used as password for other configuration like http, not only snmp. The table must have at least two entries associated with the iONOSANMsupervisor access right (this entry is created by equipement at startup with value `secret') and dIRECTACCESSsupervisor access right (this entry is created by equipement at startup with value 'supervisor') . According to equipment implementation, it is possible to create other entries associed with lower rights that PDU community string can afford (actualy equal if IONOSANMsupervisor status is granted). If the other access rights are created at startup by the equipment, its must use the following values : 'private' for 'iONOSANMoperator, 'public' for 'iONOSANMobserver', 'operator' for dIRECTACCESSoperator, 'observer' for dIRECTACCESSobserver, and 'client' for the others. All community string can be modified only by IONOSANMsupervisor. A dIRECTACCESS community string can be modified by dIRECTACCESSsupervisor. The reading of a community string gives *** for all access rights . An entry may be discarded by setting its community string to void string. This should not be used by the administrator or he could discard himself \"",
"::=",
"{",
"communityEntry",
"2",
"}"
],
"syntax_tree": [
[
"row",
"DisplayString"
],
null,
[
"MaxAccessPart",
"read-write"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"A unique textual string that can be used by a SNMP manager as community string. It can be also used as password for other configuration like http, not only snmp. The table must have at least two entries associated with the iONOSANMsupervisor access right (this entry is created by equipement at startup with value `secret') and dIRECTACCESSsupervisor access right (this entry is created by equipement at startup with value 'supervisor') . According to equipment implementation, it is possible to create other entries associed with lower rights that PDU community string can afford (actualy equal if IONOSANMsupervisor status is granted). If the other access rights are created at startup by the equipment, its must use the following values : 'private' for 'iONOSANMoperator, 'public' for 'iONOSANMobserver', 'operator' for dIRECTACCESSoperator, 'observer' for dIRECTACCESSobserver, and 'client' for the others. All community string can be modified only by IONOSANMsupervisor. A dIRECTACCESS community string can be modified by dIRECTACCESSsupervisor. The reading of a community string gives *** for all access rights . An entry may be discarded by setting its community string to void string. This should not be used by the administrator or he could discard himself"
],
null,
null,
null,
null
]
}