OID reference

equipDirection

1.3.6.1.4.1.1038.107.9.4

Description

This field selects the direction of data stream. When it is set to `backupDownload', only the transfert is done. When it is set to `download' the transfert is done and then the information transfert is switched in the operational state. When it is set to `switching', there is no transfert; there is only a switching.

Full description and source information

Identification

Identifier and names

Parent
1.3.6.1.4.1.1038.107.9 (equipLoad)
Node code
4
Node name
equipDirection
Category
SNMP management object
Numeric OID
1.3.6.1.4.1.1038.107.9.4
URN notation
urn:oid:1.3.6.1.4.1.1038.107.9.4
ASN.1, OID-IRI and named path variants
ASN.1 notation

{1 3 6 1 4 1 1038 107 9 4}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) sat(1038) equip(107) equipLoad(9) equipDirection(4)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) sagemDr(1038) equip(107) equipLoad(9) equipDirection(4)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) sat(1038) equip(107) equipLoad(9) equipDirection(4)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) sagemDr(1038) equip(107) equipLoad(9) equipDirection(4)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) sat(1038) equip(107) equipLoad(9) equipDirection(4)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) sagemDr(1038) equip(107) equipLoad(9) equipDirection(4)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) sat(1038) equip(107) equipLoad(9) equipDirection(4)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) sagemDr(1038) equip(107) equipLoad(9) equipDirection(4)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) sat(1038) equip(107) equipLoad(9) equipDirection(4)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) sagemDr(1038) equip(107) equipLoad(9) equipDirection(4)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) sat(1038) equip(107) equipLoad(9) equipDirection(4)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) sagemDr(1038) equip(107) equipLoad(9) equipDirection(4)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) sat(1038) equip(107) equipLoad(9) equipDirection(4)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) sagemDr(1038) equip(107) equipLoad(9) equipDirection(4)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) sat(1038) equip(107) equipLoad(9) equipDirection(4)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) sagemDr(1038) equip(107) equipLoad(9) equipDirection(4)}
  • Additional combinations skipped.
OID-IRI notation
  • /1/3/6/1/4/1/1038/107/9/4
  • /ISO/Identified-Organization/6/1/4/1/1038/107/9/4
  • /ISO/3/6/1/4/1/1038/107/9/4
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/sat/equip/equipLoad/equipDirection
  • /iso/identified-organization/dod/internet/private/enterprise/sagemDr/equip/equipLoad/equipDirection
  • /iso/identified-organization/dod/internet/private/enterprises/sat/equip/equipLoad/equipDirection
  • /iso/identified-organization/dod/internet/private/enterprises/sagemDr/equip/equipLoad/equipDirection
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/sat/equip/equipLoad/equipDirection
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/sagemDr/equip/equipLoad/equipDirection
  • /iso/identified-organization/dod/internet/private/vendor-objects/sat/equip/equipLoad/equipDirection
  • /iso/identified-organization/dod/internet/private/vendor-objects/sagemDr/equip/equipLoad/equipDirection
  • /iso/org/dod/internet/private/enterprise/sat/equip/equipLoad/equipDirection
  • /iso/org/dod/internet/private/enterprise/sagemDr/equip/equipLoad/equipDirection
  • /iso/org/dod/internet/private/enterprises/sat/equip/equipLoad/equipDirection
  • /iso/org/dod/internet/private/enterprises/sagemDr/equip/equipLoad/equipDirection
  • /iso/org/dod/internet/private/ldap-enterprise/sat/equip/equipLoad/equipDirection
  • /iso/org/dod/internet/private/ldap-enterprise/sagemDr/equip/equipLoad/equipDirection
  • /iso/org/dod/internet/private/vendor-objects/sat/equip/equipLoad/equipDirection
  • /iso/org/dod/internet/private/vendor-objects/sagemDr/equip/equipLoad/equipDirection
  • Additional combinations skipped.

SNMP properties

Value type
INTEGER
Maximum access defined by MIB
read-write
Status in MIB
current

Enumerated values

ValueName
0download
1upload
2backupDownload
3switching

Using this OID with SNMP

At least one MIB declaration places this object in a scalar group. A scalar instance uses the suffix .0.

snmpget [connection options] DEVICE .1.3.6.1.4.1.1038.107.9.4.0

Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.

Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.

The displayed source records contain one distinct definition. Compare its source records.

equipDirection   OBJECT-TYPE
      SYNTAX       INTEGER { download (0), upload(1)
			, backupDownload (2), switching (3)
	}
      MAX-ACCESS   read-write
      STATUS       current
      DESCRIPTION 
	"This field selects the direction of data stream.
	When it is set to `backupDownload', only the transfert is done.
	When it is set to `download' the transfert is done and then the 
	information transfert is switched in the operational state.
	When it is set to `switching', there is no transfert; 
	there is only  a switching. "     
      ::= { equipLoad 4 }

Meaning

Descriptions

1 unique

Identical descriptions are grouped. Different wording and device-specific notes are retained.

This field selects the direction of data stream. When it is set to `backupDownload', only the transfert is done. When it is set to `download' the transfert is done and then the information transfert is switched in the operational state. When it is set to `switching', there is no transfert; there is only a switching.

Sources for this description

Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

See 1 matching source record

Evidence

Source records

1 records

Matching descriptions are grouped; open a group to compare definitions and supporting files.

Records for description 1Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 record · 1 source

Description 1

equipDirection · currentMultiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 source

Status in source: current.

Names: equipDirection

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "equipDirection",
    "OBJECT-TYPE",
    "SYNTAX",
    "INTEGER",
    "{",
    "download",
    "(",
    "0",
    ")",
    ",",
    "upload",
    "(",
    "1",
    ")",
    ",",
    "backupDownload",
    "(",
    "2",
    ")",
    ",",
    "switching",
    "(",
    "3",
    ")",
    "}",
    "MAX-ACCESS",
    "read-write",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"This field selects the direction of data stream. When it is set to `backupDownload', only the transfert is done. When it is set to `download' the transfert is done and then the information transfert is switched in the operational state. When it is set to `switching', there is no transfert; there is only a switching. \"",
    "::=",
    "{",
    "equipLoad",
    "4",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "INTEGER",
      [
        "enumSpec",
        [
          [
            "download",
            0
          ],
          [
            "upload",
            1
          ],
          [
            "backupDownload",
            2
          ],
          [
            "switching",
            3
          ]
        ]
      ]
    ],
    null,
    [
      "MaxAccessPart",
      "read-write"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "This field selects the direction of data stream. When it is set to `backupDownload', only the transfert is done. When it is set to `download' the transfert is done and then the information transfert is switched in the operational state. When it is set to `switching', there is no transfert; there is only a switching."
    ],
    null,
    null,
    null,
    null
  ]
}

Registration

Registration authorities

First Registration Authority (inferred from ancestor 1.3.6.1.4.1.1038)

Alain Mleczko

Siblings (6)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.1038.107.9.1 equipLocalFile00
1.3.6.1.4.1.1038.107.9.2 equipServerAddress00
1.3.6.1.4.1.1038.107.9.3 equipRemoteFile00
1.3.6.1.4.1.1038.107.9.5 equipLoadProceed00
1.3.6.1.4.1.1038.107.9.6 equipLoadDiagnostic00
1.3.6.1.4.1.1038.107.9.7 equipLoadProtocole00