OID reference

xconName

1.3.6.1.4.1.1038.108.30.7

Description

A text string which identifies the name of this cross-connection. M1400 UIT-T specifies the field's format like this: NameTownA/NameSuffixA-NameTownB/NameSuffixB NameFunctionSNameSerial * NameTownX field accepts alpha-numeric and space characters. NameTownB is preceded by a '-' character. Maximum length is 12 charract…

Full description and source information

Identification

Identifier and names

Parent
1.3.6.1.4.1.1038.108.30 (xcon)
Node code
7
Node name
xconName
Category
SNMP management object
Numeric OID
1.3.6.1.4.1.1038.108.30.7
URN notation
urn:oid:1.3.6.1.4.1.1038.108.30.7
ASN.1, OID-IRI and named path variants
ASN.1 notation

{1 3 6 1 4 1 1038 108 30 7}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) sat(1038) xconnection(108) xcon(30) xconName(7)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) sagemDr(1038) xconnection(108) xcon(30) xconName(7)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) sat(1038) xconnection(108) xcon(30) xconName(7)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) sagemDr(1038) xconnection(108) xcon(30) xconName(7)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) sat(1038) xconnection(108) xcon(30) xconName(7)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) sagemDr(1038) xconnection(108) xcon(30) xconName(7)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) sat(1038) xconnection(108) xcon(30) xconName(7)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) sagemDr(1038) xconnection(108) xcon(30) xconName(7)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) sat(1038) xconnection(108) xcon(30) xconName(7)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) sagemDr(1038) xconnection(108) xcon(30) xconName(7)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) sat(1038) xconnection(108) xcon(30) xconName(7)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) sagemDr(1038) xconnection(108) xcon(30) xconName(7)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) sat(1038) xconnection(108) xcon(30) xconName(7)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) sagemDr(1038) xconnection(108) xcon(30) xconName(7)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) sat(1038) xconnection(108) xcon(30) xconName(7)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) sagemDr(1038) xconnection(108) xcon(30) xconName(7)}
  • Additional combinations skipped.
OID-IRI notation
  • /1/3/6/1/4/1/1038/108/30/7
  • /ISO/Identified-Organization/6/1/4/1/1038/108/30/7
  • /ISO/3/6/1/4/1/1038/108/30/7
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/sat/xconnection/xcon/xconName
  • /iso/identified-organization/dod/internet/private/enterprise/sagemDr/xconnection/xcon/xconName
  • /iso/identified-organization/dod/internet/private/enterprises/sat/xconnection/xcon/xconName
  • /iso/identified-organization/dod/internet/private/enterprises/sagemDr/xconnection/xcon/xconName
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/sat/xconnection/xcon/xconName
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/sagemDr/xconnection/xcon/xconName
  • /iso/identified-organization/dod/internet/private/vendor-objects/sat/xconnection/xcon/xconName
  • /iso/identified-organization/dod/internet/private/vendor-objects/sagemDr/xconnection/xcon/xconName
  • /iso/org/dod/internet/private/enterprise/sat/xconnection/xcon/xconName
  • /iso/org/dod/internet/private/enterprise/sagemDr/xconnection/xcon/xconName
  • /iso/org/dod/internet/private/enterprises/sat/xconnection/xcon/xconName
  • /iso/org/dod/internet/private/enterprises/sagemDr/xconnection/xcon/xconName
  • /iso/org/dod/internet/private/ldap-enterprise/sat/xconnection/xcon/xconName
  • /iso/org/dod/internet/private/ldap-enterprise/sagemDr/xconnection/xcon/xconName
  • /iso/org/dod/internet/private/vendor-objects/sat/xconnection/xcon/xconName
  • /iso/org/dod/internet/private/vendor-objects/sagemDr/xconnection/xcon/xconName
  • Additional combinations skipped.

SNMP properties

Value type
DisplayString
Maximum access defined by MIB
read-write
Status in MIB
current

Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.

The displayed source records contain one distinct definition. Compare its source records.

xconName        OBJECT-TYPE
      SYNTAX       DisplayString 
      MAX-ACCESS   read-write
      STATUS       current
      DESCRIPTION 
	"A text string which identifies the name of this cross-connection.
    M1400 UIT-T specifies the field's format like this:
     	NameTownA/NameSuffixA-NameTownB/NameSuffixB NameFunctionSNameSerial
     		* NameTownX field accepts alpha-numeric and space characters. 
     			NameTownB is preceded by a '-' character.
     			Maximum length is 12 charracters.
     			Not mandatory fields.
     		* NameSuffixX field accepts alpha-numeric characters. 
     		    It's preceded by a '/' character.
     		    Maximum length is 3 characters.
     		    Not mandatory fields.
     		* NameFunction field accepts alpha-numeric characters.
     		    It's followed by a 'S' character.
     		    Maximum length is 3 characters.
     		    Mandatory field.
     		    It represents the function code.
     		* NameSerial field accepts 4-figure number.
     		    Not mandatory field.
     		    It represents the serial number and will be incremented
    			automatically from the base serial number provided.
    For ADR2500 equipments:
    	Links names of a bidirectionnal link must have different name.
    	Same direction SNC protected links have an identical name."    		    
      ::= { xcon 7 }

Meaning

Descriptions

1 unique

Identical descriptions are grouped. Different wording and device-specific notes are retained.

A text string which identifies the name of this cross-connection. M1400 UIT-T specifies the field's format like this: NameTownA/NameSuffixA-NameTownB/NameSuffixB NameFunctionSNameSerial * NameTownX field accepts alpha-numeric and space characters. NameTownB is preceded by a '-' character. Maximum length is 12 charracters. Not mandatory fields. * NameSuffixX field accepts alpha-numeric characters. It's preceded by a '/' character. Maximum length is 3 characters. Not mandatory fields. * NameFunction field accepts alpha-numeric characters. It's followed by a 'S' character. Maximum length is 3 characters. Mandatory field. It represents the function code. * NameSerial field accepts 4-figure number. Not mandatory field. It represents the serial number and will be incremented automatically from the base serial number provided. For ADR2500 equipments: Links names of a bidirectionnal link must have different name. Same direction SNC protected links have an identical name.

Sources for this description

Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

See 1 matching source record

Evidence

Source records

1 records

Matching descriptions are grouped; open a group to compare definitions and supporting files.

Records for description 1Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 record · 1 source

Description 1

xconName · currentMultiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 source

Status in source: current.

Names: xconName

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "xconName",
    "OBJECT-TYPE",
    "SYNTAX",
    "DisplayString",
    "MAX-ACCESS",
    "read-write",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"A text string which identifies the name of this cross-connection. M1400 UIT-T specifies the field's format like this: NameTownA/NameSuffixA-NameTownB/NameSuffixB NameFunctionSNameSerial * NameTownX field accepts alpha-numeric and space characters. NameTownB is preceded by a '-' character. Maximum length is 12 charracters. Not mandatory fields. * NameSuffixX field accepts alpha-numeric characters. It's preceded by a '/' character. Maximum length is 3 characters. Not mandatory fields. * NameFunction field accepts alpha-numeric characters. It's followed by a 'S' character. Maximum length is 3 characters. Mandatory field. It represents the function code. * NameSerial field accepts 4-figure number. Not mandatory field. It represents the serial number and will be incremented automatically from the base serial number provided. For ADR2500 equipments: Links names of a bidirectionnal link must have different name. Same direction SNC protected links have an identical name.\"",
    "::=",
    "{",
    "xcon",
    "7",
    "}"
  ],
  "syntax_tree": [
    [
      "row",
      "DisplayString"
    ],
    null,
    [
      "MaxAccessPart",
      "read-write"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "A text string which identifies the name of this cross-connection. M1400 UIT-T specifies the field's format like this: NameTownA/NameSuffixA-NameTownB/NameSuffixB NameFunctionSNameSerial * NameTownX field accepts alpha-numeric and space characters. NameTownB is preceded by a '-' character. Maximum length is 12 charracters. Not mandatory fields. * NameSuffixX field accepts alpha-numeric characters. It's preceded by a '/' character. Maximum length is 3 characters. Not mandatory fields. * NameFunction field accepts alpha-numeric characters. It's followed by a 'S' character. Maximum length is 3 characters. Mandatory field. It represents the function code. * NameSerial field accepts 4-figure number. Not mandatory field. It represents the serial number and will be incremented automatically from the base serial number provided. For ADR2500 equipments: Links names of a bidirectionnal link must have different name. Same direction SNC protected links have an identical name."
    ],
    null,
    null,
    null,
    null
  ]
}

Registration

Registration authorities

First Registration Authority (inferred from ancestor 1.3.6.1.4.1.1038)

Alain Mleczko

Siblings (9)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.1038.108.30.1 xconNumber00
1.3.6.1.4.1.1038.108.30.2 xconSinkType00
1.3.6.1.4.1.1038.108.30.3 xconSinkIndex00
1.3.6.1.4.1.1038.108.30.4 xconSrcType00
1.3.6.1.4.1.1038.108.30.5 xconSrcIndex00
1.3.6.1.4.1.1038.108.30.6 xconDirection00
1.3.6.1.4.1.1038.108.30.8 xconAction00
1.3.6.1.4.1.1038.108.30.20 xconProceed00
1.3.6.1.4.1.1038.108.30.21 xconDiagnostic00