Status in source: current.
Names: fsElpsPgConfigRowStatus
Technical details
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"fsElpsPgConfigRowStatus",
"OBJECT-TYPE",
"SYNTAX",
"RowStatus",
"MAX-ACCESS",
"read-write",
"STATUS",
"current",
"DESCRIPTION",
"\"This object indicates the status of this row/entry. Setting this object to Active is not allowed in the following scenarios: - If the value of the column fsElpsPgConfigMonitorMechanism is set to 'cfm/mplsOam' and there is no active entry corresponding to this protection group present in the fsElpsPgCfmTable table. - If the value of the column fsElpsPgConfigType is set to 'list' and there is no active entry corresponding to this protection group in the fsElpsPgServiceListTable table or fsElpsPgServiceListPointerTable. - If the value of the column fsElpsPgConfigType is set to 'list' and a valid non-zero value is set in the fsElpsPgConfigWorkingServiceValue and fsElpsPgConfigProtectionServiceValue columns of this table. Setting the rowstatus value 'destroy' to this object will delete the related entries present in fsElpsPgCfmTable, fsElpsPgServiceListTable / fsElpsPgServiceListPointerTable. The writable columns in any row of this table cannot be changed while the row is active.\"",
"::=",
"{",
"fsElpsPgConfigEntry",
"13",
"}"
],
"syntax_tree": [
[
"row",
"RowStatus"
],
null,
[
"MaxAccessPart",
"read-write"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"This object indicates the status of this row/entry. Setting this object to Active is not allowed in the following scenarios: - If the value of the column fsElpsPgConfigMonitorMechanism is set to 'cfm/mplsOam' and there is no active entry corresponding to this protection group present in the fsElpsPgCfmTable table. - If the value of the column fsElpsPgConfigType is set to 'list' and there is no active entry corresponding to this protection group in the fsElpsPgServiceListTable table or fsElpsPgServiceListPointerTable. - If the value of the column fsElpsPgConfigType is set to 'list' and a valid non-zero value is set in the fsElpsPgConfigWorkingServiceValue and fsElpsPgConfigProtectionServiceValue columns of this table. Setting the rowstatus value 'destroy' to this object will delete the related entries present in fsElpsPgCfmTable, fsElpsPgServiceListTable / fsElpsPgServiceListPointerTable. The writable columns in any row of this table cannot be changed while the row is active."
],
null,
null,
null,
null
]
}
- Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
· Publisher's source file: Source package: observium-community-latest.tar.gz
Vendor MIB copy from the Observium Community archive.
Module: SUPERMICRO-ELPS-MIB
See published definition above
Module imports
{'IF-MIB': ['InterfaceIndex', 'InterfaceIndexOrZero'], 'SNMPv2-TC': ['RowStatus', 'RowPointer', 'TruthValue', 'DisplayString', 'TEXTUAL-CONVENTION'], 'SNMPv2-SMI': ['OBJECT-TYPE', 'MODULE-IDENTITY', 'enterprises', 'Unsigned32', 'Counter32', 'NOTIFICATION-TYPE'], 'IEEE8021-CFM-MIB': ['Dot1agCfmMepId']}
· Download SUPERMICRO-ELPS-MIB
Related source files and packages: