Status in source: current.
Technical details
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"hpnicfDot3OamEventLogWindowLo",
"OBJECT-TYPE",
"SYNTAX",
"Unsigned32",
"MAX-ACCESS",
"read-only",
"STATUS",
"current",
"DESCRIPTION",
"\"If the event represents a threshold crossing event, the two objects hpnicfDot3OamEventWindowHi and hpnicfDot3OamEventWindowLo form an unsigned 64-bit integer yielding the window over which the value was measured for the threshold crossing event (e.g. 5, when 11 occurrences happened in 5 seconds while the threshold was 10). The two objects are combined as: hpnicfDot3OamEventLogWindow = ((2^32) * hpnicfDot3OamEventLogWindowHi) + hpnicfDot3OamEventLogWindowLo Otherwise, this value is returned as all F's (0xFFFFFFFF) and adds no useful information. \"",
"REFERENCE",
"\"[802.3ah], 30.3.6.1.37 and 57.5.3.2.\"",
"::=",
"{",
"hpnicfDot3OamEventLogEntry",
"7",
"}"
],
"syntax_tree": [
[
"ApplicationSyntax",
"Unsigned32"
],
null,
[
"MaxAccessPart",
"read-only"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"If the event represents a threshold crossing event, the two objects hpnicfDot3OamEventWindowHi and hpnicfDot3OamEventWindowLo form an unsigned 64-bit integer yielding the window over which the value was measured for the threshold crossing event (e.g. 5, when 11 occurrences happened in 5 seconds while the threshold was 10). The two objects are combined as: hpnicfDot3OamEventLogWindow = ((2^32) * hpnicfDot3OamEventLogWindowHi) + hpnicfDot3OamEventLogWindowLo Otherwise, this value is returned as all F's (0xFFFFFFFF) and adds no useful information."
],
[
"REFERENCE",
"[802.3ah], 30.3.6.1.37 and 57.5.3.2."
],
null,
null,
null
]
}