If this is a Field Replaceable Unit or if it is part of another FRU, this provides an index into the FRU table; 'value = -1' indicates that the group is not a FRU.
Sources for this description
Symbios storage MIB copies (IPNetwork Monitor archive)
OID reference
1.3.6.1.4.1.1123.3.1.2.4.1.7.1.8
If this is a Field Replaceable Unit or if it is part of another FRU, this provides an index into the FRU table; 'value = -1' indicates that the group is not a FRU.
Identification
{1 3 6 1 4 1 1123 3 1 2 4 1 7 1 8}
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
The displayed source records contain one distinct definition. Compare its source records.
a7FruGroupIndex OBJECT-TYPE
SYNTAX DmiInteger
ACCESS read-only
STATUS mandatory
DESCRIPTION "If this is a Field Replaceable Unit or if it is part of another
FRU, this provides an index into the FRU table; 'value = -1' indicates that
the group is not a FRU."
::= {eStorageController 8}
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
If this is a Field Replaceable Unit or if it is part of another FRU, this provides an index into the FRU table; 'value = -1' indicates that the group is not a FRU.
Symbios storage MIB copies (IPNetwork Monitor archive)
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: mandatory.
Names: a7FruGroupIndex
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"a7FruGroupIndex",
"OBJECT-TYPE",
"SYNTAX",
"DmiInteger",
"ACCESS",
"read-only",
"STATUS",
"mandatory",
"DESCRIPTION",
"\"If this is a Field Replaceable Unit or if it is part of another FRU, this provides an index into the FRU table; 'value = -1' indicates that the group is not a FRU.\"",
"::=",
"{",
"eStorageController",
"8",
"}"
],
"syntax_tree": [
[
"row",
"DmiInteger"
],
null,
[
"MaxAccessPart",
"read-only"
],
[
"Status",
"mandatory"
],
[
"DESCRIPTION",
"If this is a Field Replaceable Unit or if it is part of another FRU, this provides an index into the FRU table; 'value = -1' indicates that the group is not a FRU."
],
null,
null,
null,
null
]
}Module: SYMBIOSSDMSMASSSTORAGESYSTEMMIFDEF2-MIB
See published definition above
{'RFC-1212': ['OBJECT-TYPE'], 'RFC1155-SMI': ['Counter', 'enterprises'], 'RFC1213-MIB': ['DisplayString']}Source data warning: This is a third-party archive copy attributed to Symbios Logic; the original manufacturer distribution and edition have not been independently confirmed. The file states it was generated by miftomib version 1.0a, and it has no explicit publication date; applicability to current devices is unconfirmed.
· Download Symbios mass storage MIB — IPNetwork Monitor archive copyRegistration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.1123.3.1.2.4.1.7.1.1 | a7ControllerIndex | 0 | 0 | |
| 1.3.6.1.4.1.1123.3.1.2.4.1.7.1.2 | a7Identification | 0 | 0 | |
| 1.3.6.1.4.1.1123.3.1.2.4.1.7.1.3 | a7WorldwideIdentifierType | 0 | 0 | |
| 1.3.6.1.4.1.1123.3.1.2.4.1.7.1.4 | a7WorldwideIdentifier | 0 | 0 | |
| 1.3.6.1.4.1.1123.3.1.2.4.1.7.1.5 | a7ProtectionManagement | 0 | 0 | |
| 1.3.6.1.4.1.1123.3.1.2.4.1.7.1.6 | a7BusMaster | 0 | 0 | |
| 1.3.6.1.4.1.1123.3.1.2.4.1.7.1.7 | a7SecondsSinceLastPower-up | 0 | 0 | |
| 1.3.6.1.4.1.1123.3.1.2.4.1.7.1.9 | a7OperationalGroupIndex | 0 | 0 |