OID reference

apexAlarmChassisRedundancySecondaryFailover

1.3.6.1.4.1.1166.1.31.100.8091

Description

Generated when the secondary active APEX fails over to the primary standby unit. Trap tells if failover is operator induced, or automatic because of a fault. Major if automatic due to some fault Warning if force-failover. Cleared when redundancy is disabled or when the secondary becomes active and the primary is stand…

Full description and source information

Identification

Identifier and names

Parent
1.3.6.1.4.1.1166.1.31.100 (apexAlarms)
Node code
8091
Node name
apexAlarmChassisRedundancySecondaryFailover
Category
SNMP management object
Numeric OID
1.3.6.1.4.1.1166.1.31.100.8091
URN notation
urn:oid:1.3.6.1.4.1.1166.1.31.100.8091
ASN.1, OID-IRI and named path variants
ASN.1 notation

{1 3 6 1 4 1 1166 1 31 100 8091}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) gi(1166) giproducts(1) apex(31) apexAlarms(100) apexAlarmChassisRedundancySecondaryFailover(8091)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) giMIB(1166) giproducts(1) apex(31) apexAlarms(100) apexAlarmChassisRedundancySecondaryFailover(8091)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) gi(1166) giproducts(1) apex(31) apexAlarms(100) apexAlarmChassisRedundancySecondaryFailover(8091)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) giMIB(1166) giproducts(1) apex(31) apexAlarms(100) apexAlarmChassisRedundancySecondaryFailover(8091)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) gi(1166) giproducts(1) apex(31) apexAlarms(100) apexAlarmChassisRedundancySecondaryFailover(8091)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) giMIB(1166) giproducts(1) apex(31) apexAlarms(100) apexAlarmChassisRedundancySecondaryFailover(8091)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) gi(1166) giproducts(1) apex(31) apexAlarms(100) apexAlarmChassisRedundancySecondaryFailover(8091)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) giMIB(1166) giproducts(1) apex(31) apexAlarms(100) apexAlarmChassisRedundancySecondaryFailover(8091)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) gi(1166) giproducts(1) apex(31) apexAlarms(100) apexAlarmChassisRedundancySecondaryFailover(8091)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) giMIB(1166) giproducts(1) apex(31) apexAlarms(100) apexAlarmChassisRedundancySecondaryFailover(8091)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) gi(1166) giproducts(1) apex(31) apexAlarms(100) apexAlarmChassisRedundancySecondaryFailover(8091)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) giMIB(1166) giproducts(1) apex(31) apexAlarms(100) apexAlarmChassisRedundancySecondaryFailover(8091)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) gi(1166) giproducts(1) apex(31) apexAlarms(100) apexAlarmChassisRedundancySecondaryFailover(8091)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) giMIB(1166) giproducts(1) apex(31) apexAlarms(100) apexAlarmChassisRedundancySecondaryFailover(8091)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) gi(1166) giproducts(1) apex(31) apexAlarms(100) apexAlarmChassisRedundancySecondaryFailover(8091)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) giMIB(1166) giproducts(1) apex(31) apexAlarms(100) apexAlarmChassisRedundancySecondaryFailover(8091)}
  • Additional combinations skipped.
OID-IRI notation
  • /1/3/6/1/4/1/1166/1/31/100/8091
  • /ISO/Identified-Organization/6/1/4/1/1166/1/31/100/8091
  • /ISO/3/6/1/4/1/1166/1/31/100/8091
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/1166/giproducts/apex/apexAlarms/apexAlarmChassisRedundancySecondaryFailover
  • /iso/identified-organization/dod/internet/private/enterprise/gi/giproducts/apex/apexAlarms/apexAlarmChassisRedundancySecondaryFailover
  • /iso/identified-organization/dod/internet/private/enterprise/giMIB/giproducts/apex/apexAlarms/apexAlarmChassisRedundancySecondaryFailover
  • /iso/identified-organization/dod/internet/private/enterprises/1166/giproducts/apex/apexAlarms/apexAlarmChassisRedundancySecondaryFailover
  • /iso/identified-organization/dod/internet/private/enterprises/gi/giproducts/apex/apexAlarms/apexAlarmChassisRedundancySecondaryFailover
  • /iso/identified-organization/dod/internet/private/enterprises/giMIB/giproducts/apex/apexAlarms/apexAlarmChassisRedundancySecondaryFailover
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/1166/giproducts/apex/apexAlarms/apexAlarmChassisRedundancySecondaryFailover
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/gi/giproducts/apex/apexAlarms/apexAlarmChassisRedundancySecondaryFailover
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/giMIB/giproducts/apex/apexAlarms/apexAlarmChassisRedundancySecondaryFailover
  • /iso/identified-organization/dod/internet/private/vendor-objects/1166/giproducts/apex/apexAlarms/apexAlarmChassisRedundancySecondaryFailover
  • /iso/identified-organization/dod/internet/private/vendor-objects/gi/giproducts/apex/apexAlarms/apexAlarmChassisRedundancySecondaryFailover
  • /iso/identified-organization/dod/internet/private/vendor-objects/giMIB/giproducts/apex/apexAlarms/apexAlarmChassisRedundancySecondaryFailover
  • /iso/org/dod/internet/private/enterprise/1166/giproducts/apex/apexAlarms/apexAlarmChassisRedundancySecondaryFailover
  • /iso/org/dod/internet/private/enterprise/gi/giproducts/apex/apexAlarms/apexAlarmChassisRedundancySecondaryFailover
  • /iso/org/dod/internet/private/enterprise/giMIB/giproducts/apex/apexAlarms/apexAlarmChassisRedundancySecondaryFailover
  • /iso/org/dod/internet/private/enterprises/1166/giproducts/apex/apexAlarms/apexAlarmChassisRedundancySecondaryFailover
  • Additional combinations skipped.

SNMP properties

Value type
INTEGER
Maximum access defined by MIB
read-only
Status in MIB
current

Enumerated values

ValueName
1ok
2indeterminate
3warning
4minor
5major
6critical

Using this OID with SNMP

At least one MIB declaration places this object in a scalar group. A scalar instance uses the suffix .0.

snmpget [connection options] DEVICE .1.3.6.1.4.1.1166.1.31.100.8091.0

Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.

Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.

The displayed source records contain one distinct definition. Compare its source records.

apexAlarmChassisRedundancySecondaryFailover OBJECT-TYPE
    SYNTAX INTEGER
        {
         ok(1),
         indeterminate(2),
         warning(3),
         minor(4),
         major(5),
         critical(6)
        }
    MAX-ACCESS read-only
    STATUS current
    DESCRIPTION
        "Generated when the secondary active APEX fails over to the primary standby unit.
        Trap tells if failover is operator induced, or automatic because of a fault.
        Major if automatic due to some fault Warning if force-failover.
        Cleared when redundancy is disabled or when the secondary becomes active and
        the primary is standby.
        "
        --MOT-MIBCOMP-BE-EXT <DbHint map="SCALAR" crs_fmt="1" crs_desc="Chassis Redundancy Secondary FailOver."
        --crs_define="EC_CHASSIS_REDUNDANCY_SECONDARY_FAILOVER_ALARM"></DbHint>

::= { apexAlarms 8091 }

Meaning

Descriptions

1 unique

Identical descriptions are grouped. Different wording and device-specific notes are retained.

Generated when the secondary active APEX fails over to the primary standby unit. Trap tells if failover is operator induced, or automatic because of a fault. Major if automatic due to some fault Warning if force-failover. Cleared when redundancy is disabled or when the secondary becomes active and the primary is standby.

Sources for this description

Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

See 1 matching source record

Evidence

Source records

1 records

Matching descriptions are grouped; open a group to compare definitions and supporting files.

Records for description 1Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 record · 1 source

Description 1

apexAlarmChassisRedundancySecondaryFailover · currentMultiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 source

Status in source: current.

Names: apexAlarmChassisRedundancySecondaryFailover

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "apexAlarmChassisRedundancySecondaryFailover",
    "OBJECT-TYPE",
    "SYNTAX",
    "INTEGER",
    "{",
    "ok",
    "(",
    "1",
    ")",
    ",",
    "indeterminate",
    "(",
    "2",
    ")",
    ",",
    "warning",
    "(",
    "3",
    ")",
    ",",
    "minor",
    "(",
    "4",
    ")",
    ",",
    "major",
    "(",
    "5",
    ")",
    ",",
    "critical",
    "(",
    "6",
    ")",
    "}",
    "MAX-ACCESS",
    "read-only",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"Generated when the secondary active APEX fails over to the primary standby unit. Trap tells if failover is operator induced, or automatic because of a fault. Major if automatic due to some fault Warning if force-failover. Cleared when redundancy is disabled or when the secondary becomes active and the primary is standby. \"",
    "::=",
    "{",
    "apexAlarms",
    "8091",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "INTEGER",
      [
        "enumSpec",
        [
          [
            "ok",
            1
          ],
          [
            "indeterminate",
            2
          ],
          [
            "warning",
            3
          ],
          [
            "minor",
            4
          ],
          [
            "major",
            5
          ],
          [
            "critical",
            6
          ]
        ]
      ]
    ],
    null,
    [
      "MaxAccessPart",
      "read-only"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "Generated when the secondary active APEX fails over to the primary standby unit. Trap tells if failover is operator induced, or automatic because of a fault. Major if automatic due to some fault Warning if force-failover. Cleared when redundancy is disabled or when the secondary becomes active and the primary is standby."
    ],
    null,
    null,
    null,
    null
  ]
}

Registration

Registration authorities

First Registration Authority (inferred from ancestor 1.3.6.1.4.1.1166)

Fred Gotwald

Siblings (36)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.1166.1.31.100.8000 apexAlarmHardwareFault00
1.3.6.1.4.1.1166.1.31.100.8001 apexAlarmInvalidInitData00
1.3.6.1.4.1.1166.1.31.100.8002 apexAlarmTemperatureFault00
1.3.6.1.4.1.1166.1.31.100.8003 apexAlarmFanFault00
1.3.6.1.4.1.1166.1.31.100.8004 apexAlarmPowerFault00
1.3.6.1.4.1.1166.1.31.100.8020 apexAlarmGbeLossOfPhysicalInput00
1.3.6.1.4.1.1166.1.31.100.8021 apexAlarmGbeBufferFullness00
1.3.6.1.4.1.1166.1.31.100.8022 apexAlarmGbeInputStreamLowBitRate00
1.3.6.1.4.1.1166.1.31.100.8023 apexAlarmGbeInputStreamHighBitRate00
1.3.6.1.4.1.1166.1.31.100.8024 apexAlarmGbeMptsRedundPrimaryThreshold00
1.3.6.1.4.1.1166.1.31.100.8025 apexAlarmGbeMptsRedundFailOver00
1.3.6.1.4.1.1166.1.31.100.8026 apexAlarmServiceInError00
1.3.6.1.4.1.1166.1.31.100.8027 apexAlarmGbeLossOfInputStream00
1.3.6.1.4.1.1166.1.31.100.8028 apexAlarmGigeToHostCommFault00
1.3.6.1.4.1.1166.1.31.100.8029 apexAlarmGbeInterfaceRedundFailOver00
1.3.6.1.4.1.1166.1.31.100.8030 apexAlarmLossOfInputAncillaryPid00
1.3.6.1.4.1.1166.1.31.100.8031 apexAlarmGbeInputStreamPacketDrop00
1.3.6.1.4.1.1166.1.31.100.8040 apexAlarmOutputUtilizationFault00
1.3.6.1.4.1.1166.1.31.100.8041 apexAlarmOutputOverflow00
1.3.6.1.4.1.1166.1.31.100.8042 apexAlarmQamModuleFault00
1.3.6.1.4.1.1166.1.31.100.8043 apexAlarmQamRfPortFault00
1.3.6.1.4.1.1166.1.31.100.8044 apexAlarmQamChannelFault00
1.3.6.1.4.1.1166.1.31.100.8045 apexAlarmQamRfRedundFailOver00
1.3.6.1.4.1.1166.1.31.100.8046 apexAlarmQamRfRedundMismatch00
1.3.6.1.4.1.1166.1.31.100.8047 apexAlarmQamModuleRemovalFault00
1.3.6.1.4.1.1166.1.31.100.8050 apexAlarmRtspControllerCommFault00
1.3.6.1.4.1.1166.1.31.100.8060 apexAlarmRdsCommFault00
1.3.6.1.4.1.1166.1.31.100.8070 apexAlarmRemCommFault00
1.3.6.1.4.1.1166.1.31.100.8071 apexAlarmRemFault00
1.3.6.1.4.1.1166.1.31.100.8080 apexAlarmDepiControlConnectionFault00
1.3.6.1.4.1.1166.1.31.100.8081 apexAlarmDepiSessionSetupFault00
1.3.6.1.4.1.1166.1.31.100.8082 apexAlarmDtiSyncLossFault00
1.3.6.1.4.1.1166.1.31.100.8090 apexAlarmChassisRedundancyPrimaryFailover00
1.3.6.1.4.1.1166.1.31.100.8092 apexAlarmChassisRedundancyAvailabilityFault00
1.3.6.1.4.1.1166.1.31.100.8093 apexAlarmChassisRedundancyLinkFault00
1.3.6.1.4.1.1166.1.31.100.8094 apexAlarmChassisRedundancyConfigurationFault00