Status in source: current.
Names: apexEasServerRcvUdpPort
Technical details
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"apexEasServerRcvUdpPort",
"OBJECT-TYPE",
"SYNTAX",
"Integer32",
"(",
"0",
".",
".",
"65535",
")",
"MAX-ACCESS",
"read-write",
"STATUS",
"current",
"DESCRIPTION",
"\"This parameter indicates the UDP port on which to receive EAS messages. Range is 1024 to 65535 when apexEasServerPhysInType is 'fastEnet'. Range is 0 to 65535 when apexEasServerPhysInType is 'gbe'. Once written, the change to this parameter will only take immediate effect after apexEasServerApplyChange is set to 'apply'. In order for the change to persist through subsequent reboots or power cycles, the change must be saved via the apexSaveConfig parameter. \"",
"::=",
"{",
"apexEasServerEntry",
"4",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"Integer32",
[
"integerSubType",
[
[
0,
65535
]
]
]
],
null,
[
"MaxAccessPart",
"read-write"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"This parameter indicates the UDP port on which to receive EAS messages. Range is 1024 to 65535 when apexEasServerPhysInType is 'fastEnet'. Range is 0 to 65535 when apexEasServerPhysInType is 'gbe'. Once written, the change to this parameter will only take immediate effect after apexEasServerApplyChange is set to 'apply'. In order for the change to persist through subsequent reboots or power cycles, the change must be saved via the apexSaveConfig parameter."
],
null,
null,
null,
null
]
}