Status in source: current.
Technical details
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"apexQamModuleStatError",
"OBJECT-TYPE",
"SYNTAX",
"INTEGER",
"{",
"notApplicable",
"(",
"0",
")",
",",
"ok",
"(",
"1",
")",
",",
"removed",
"(",
"2",
")",
",",
"unsupported",
"(",
"3",
")",
",",
"notInstalled",
"(",
"4",
")",
",",
"powerFault",
"(",
"5",
")",
",",
"offline",
"(",
"6",
")",
",",
"dc5VoltError",
"(",
"7",
")",
",",
"dc3-3VoltError",
"(",
"8",
")",
",",
"commLost",
"(",
"9",
")",
",",
"codeVersions",
"(",
"10",
")",
",",
"codeDownload",
"(",
"11",
")",
",",
"codeDownloadError",
"(",
"12",
")",
"}",
"MAX-ACCESS",
"read-only",
"STATUS",
"current",
"DESCRIPTION",
"\"Summary of errors reported on an QAM Module basis. These errors are reported in apexAlarmQamModuleFault. ok - No errors. removed - Reflects apexQamModuleStatInstalled. unsupported - Reflects apexQamModuleStatInstalled. notInstalled - Reflects apexQamModuleStatInstalled. powerFault - Reflects apexQamModuleStatPowerFault. offline - Indicates the QAM Module and the RF Ports on it are being brought to operational mode after module is inserted or the module has recovered from a power fault. dc5VoltError - 5 Vdc error, see also apexQamModuleStat5VdcSupply and apexQamModuleStat5VdcFault. dc3-3VoltError - 3.3 Vdc error, see also apexQamModuleStat3dot3VdcSupply and apexQamModuleStat3dot3VdcFault. commLost - Communication Lost, see also apexQamModuleStatCommError. codeVersions - Incorrect Code Versions on module, see also apexQamModuleStatCodeInitError, apexQamQrmRevisionTable, and apexQamQrmRevisionStatusTable. codeDownload - Code Download In Progress, see also apexQrmDownloadStatusTable. codeDownloadError - Code Download Error, see also apexQrmDownloadStatusTable. \"",
"::=",
"{",
"apexQamModuleStatusEntry",
"7",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"INTEGER",
[
"enumSpec",
[
[
"notApplicable",
0
],
[
"ok",
1
],
[
"removed",
2
],
[
"unsupported",
3
],
[
"notInstalled",
4
],
[
"powerFault",
5
],
[
"offline",
6
],
[
"dc5VoltError",
7
],
[
"dc3-3VoltError",
8
],
[
"commLost",
9
],
[
"codeVersions",
10
],
[
"codeDownload",
11
],
[
"codeDownloadError",
12
]
]
]
],
null,
[
"MaxAccessPart",
"read-only"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"Summary of errors reported on an QAM Module basis. These errors are reported in apexAlarmQamModuleFault. ok - No errors. removed - Reflects apexQamModuleStatInstalled. unsupported - Reflects apexQamModuleStatInstalled. notInstalled - Reflects apexQamModuleStatInstalled. powerFault - Reflects apexQamModuleStatPowerFault. offline - Indicates the QAM Module and the RF Ports on it are being brought to operational mode after module is inserted or the module has recovered from a power fault. dc5VoltError - 5 Vdc error, see also apexQamModuleStat5VdcSupply and apexQamModuleStat5VdcFault. dc3-3VoltError - 3.3 Vdc error, see also apexQamModuleStat3dot3VdcSupply and apexQamModuleStat3dot3VdcFault. commLost - Communication Lost, see also apexQamModuleStatCommError. codeVersions - Incorrect Code Versions on module, see also apexQamModuleStatCodeInitError, apexQamQrmRevisionTable, and apexQamQrmRevisionStatusTable. codeDownload - Code Download In Progress, see also apexQrmDownloadStatusTable. codeDownloadError - Code Download Error, see also apexQrmDownloadStatusTable."
],
null,
null,
null,
null
]
}