This object is not used by this module and always returns the value of the Channel 2 Received Opt power Major High Alarm Limit Analog parameter.
Sources for this description
General Instrument GX2 MIB copies with Oracle inventory
OID reference
1.3.6.1.4.1.1166.6.1.2.35.2.1.16
This object is not used by this module and always returns the value of the Channel 2 Received Opt power Major High Alarm Limit Analog parameter.
Identification
{1 3 6 1 4 1 1166 6 1 2 35 2 1 16}
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
The displayed source records contain one distinct definition. Compare its source records.
dualdrr2xmajorLowRecdOptPwr2 OBJECT-TYPE
SYNTAX Float
ACCESS read-only
STATUS obsolete
DESCRIPTION
"This object is not used by this module and always returns the value of the
Channel 2 Received Opt power Major High Alarm Limit Analog parameter."
::= { gx2dualdrr2xAnalogEntry 16}
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
This object is not used by this module and always returns the value of the Channel 2 Received Opt power Major High Alarm Limit Analog parameter.
General Instrument GX2 MIB copies with Oracle inventory
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: obsolete.
Names: dualdrr2xmajorLowRecdOptPwr2
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"dualdrr2xmajorLowRecdOptPwr2",
"OBJECT-TYPE",
"SYNTAX",
"Float",
"ACCESS",
"read-only",
"STATUS",
"obsolete",
"DESCRIPTION",
"\"This object is not used by this module and always returns the value of the Channel 2 Received Opt power Major High Alarm Limit Analog parameter.\"",
"::=",
"{",
"gx2dualdrr2xAnalogEntry",
"16",
"}"
],
"syntax_tree": [
[
"row",
"Float"
],
null,
[
"MaxAccessPart",
"read-only"
],
[
"Status",
"obsolete"
],
[
"DESCRIPTION",
"This object is not used by this module and always returns the value of the Channel 2 Received Opt power Major High Alarm Limit Analog parameter."
],
null,
null,
null,
null
]
}Module: OMNI-gx2dualdrr2x-MIB
See published definition above
{'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'GX2HFC-MIB': ['gx2DualDrr2x'], 'RFC1155-SMI': ['Counter'], 'RFC1213-MIB': ['DisplayString'], 'NLSBBN-TRAPS-MIB': ['trapIdentifier', 'trapNetworkElemModelNumber', 'trapNetworkElemSerialNum', 'trapPerceivedSeverity', 'trapNetworkElemOperState', 'trapNetworkElemAlarmStatus', 'trapNetworkElemAdminState', 'trapNetworkElemAvailStatus', 'trapText', 'trapNETrapLastTrapTimeStamp', 'trapChangedObjectId', 'trapChangedValueInteger', 'trapChangedValueDisplayString']}Source data warning: This is a third-party IPNetwork Monitor archive copy attributed to General Instrument, Motorola or ARRIS. Oracle lists the corresponding module family as supported; the manufacturer distribution and applicability to particular devices or firmware have not been independently confirmed.
· Download General Instrument OMNI-gx2dualdrr2x-MIB — IPNetwork Monitor archive copyRelated source files and packages:
Registration