Status in source: deprecated.
Names: eventClearConfiguration
Technical details
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"eventClearConfiguration",
"OBJECT-TYPE",
"SYNTAX",
"Integer32",
"(",
"0",
".",
".",
"65535",
")",
"MAX-ACCESS",
"read-write",
"STATUS",
"deprecated",
"DESCRIPTION",
"\"<Definition>This object contains the event configuration(s) to clear from the report node. A SET of n = 1..65535, n <= maxEventLogConfigs shall cause all information related to that configuration to be cleared from the report node. This includes clearing the event configuration table for all eventConfigID = n data, and clearing all event log entries for eventConfigID = n. A SET of 0 shall clear all configurations within the device as described (i.e. completely clear the report node with the exception that the eventClassTable is and preconfigured event configuration are not altered). A GET shall always return zero (0). Note: This object cannot be included in a block object. The device shall respond with badValue if the eventLogConfig = n does not exist. The device shall respond with badValue if an attempt to clear a preconfigured event log entries is made. <Superseded by> LOG-MIB. fdLogEventFactoryRowStatus (ISO 20684-5) & COND-TRIGGER-MIB.fdCondTriggerRowStatus (ISO 20684-3) <Informative> A user can separately delete the trigger and the factory. <Object Identifier> 1.3.6.1.4.1.1206.4.1.1.7.8.2\"",
"::=",
"{",
"eventClearObjects",
"2",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"Integer32",
[
"integerSubType",
[
[
0,
65535
]
]
]
],
null,
[
"MaxAccessPart",
"read-write"
],
[
"Status",
"deprecated"
],
[
"DESCRIPTION",
"<Definition>This object contains the event configuration(s) to clear from the report node. A SET of n = 1..65535, n <= maxEventLogConfigs shall cause all information related to that configuration to be cleared from the report node. This includes clearing the event configuration table for all eventConfigID = n data, and clearing all event log entries for eventConfigID = n. A SET of 0 shall clear all configurations within the device as described (i.e. completely clear the report node with the exception that the eventClassTable is and preconfigured event configuration are not altered). A GET shall always return zero (0). Note: This object cannot be included in a block object. The device shall respond with badValue if the eventLogConfig = n does not exist. The device shall respond with badValue if an attempt to clear a preconfigured event log entries is made. <Superseded by> LOG-MIB. fdLogEventFactoryRowStatus (ISO 20684-5) & COND-TRIGGER-MIB.fdCondTriggerRowStatus (ISO 20684-3) <Informative> A user can separately delete the trigger and the factory. <Object Identifier> 1.3.6.1.4.1.1206.4.1.1.7.8.2"
],
null,
null,
null,
null
]
}
- ITE public NTCIP working repository MIBs
· Publisher's source file: NTCIP-1201 — ntcip1201-AuxIO.mib
Module: NTCIP1201-NtcipTraps
See published definition above
Module imports
{'SNMPv2-TC': ['DisplayString'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'Integer32', 'Unsigned32', 'Counter32', 'IpAddress', 'zeroDotZero'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'NOTIFICATION-GROUP'], 'NTCIP1201-Report': ['eventConfigID'], 'FIELD-DEVICE-TC-MIB': ['ITSOerString'], 'NTCIP8004-Transportation': ['application', 'protocols', 'NtcipRowStatusStatic']}
Source data warning: This original is published in an ITE NTCIP working repository. Repository publication does not establish that this particular revision is an adopted standard. Consult its native revision history and the NTCIP published standards catalog before implementation. Copyright and distribution notices are retained in the downloadable original.
· Download NTCIP-1201 — ntcip1201-AuxIO.mib
Same file in ntcip1201-SNMPConfig.mib.
Same file in ntcip1201-Security.mib.
Same file in ntcip1201-ProfilesSTMP.mib.