OID reference

rsuSpatStatus

1.3.6.1.4.1.1206.4.18.21.9

Description

<Definition> If a bit is enabled or active, the associated bit shall be set to (1). The definition of the term 'recent' is defined by the system in use. Bit 0 is equal to Bit 0 of the BIT STRING of DE_IntersectionStatusObject, Bit 1 is equal to Bit 1, etc. Bit 0: Enabled when unitControlStatus is remoteManualControl (…

Full description and source information

Identification

Identifier and names

Parent
1.3.6.1.4.1.1206.4.18.21 (21)
Node code
9
Node name
rsuSpatStatus
Category
SNMP management object
Numeric OID
1.3.6.1.4.1.1206.4.18.21.9
URN notation
urn:oid:1.3.6.1.4.1.1206.4.18.21.9
ASN.1, OID-IRI and named path variants
ASN.1 notation

{1 3 6 1 4 1 1206 4 18 21 9}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) nema(1206) transportation(4) 18 21 rsuSpatStatus(9)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) nema(1206) transportation(4) 18 21 rsuSpatStatus(9)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) nema(1206) transportation(4) 18 21 rsuSpatStatus(9)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) nema(1206) transportation(4) 18 21 rsuSpatStatus(9)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) nema(1206) transportation(4) 18 21 rsuSpatStatus(9)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) nema(1206) transportation(4) 18 21 rsuSpatStatus(9)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) nema(1206) transportation(4) 18 21 rsuSpatStatus(9)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) nema(1206) transportation(4) 18 21 rsuSpatStatus(9)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprise(1) nema(1206) transportation(4) 18 21 rsuSpatStatus(9)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) nema(1206) transportation(4) 18 21 rsuSpatStatus(9)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) nema(1206) transportation(4) 18 21 rsuSpatStatus(9)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) nema(1206) transportation(4) 18 21 rsuSpatStatus(9)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) enterprise(1) nema(1206) transportation(4) 18 21 rsuSpatStatus(9)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) enterprises(1) nema(1206) transportation(4) 18 21 rsuSpatStatus(9)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) nema(1206) transportation(4) 18 21 rsuSpatStatus(9)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) vendor-objects(1) nema(1206) transportation(4) 18 21 rsuSpatStatus(9)}
OID-IRI notation
  • /1/3/6/1/4/1/1206/4/18/21/9
  • /ISO/Identified-Organization/6/1/4/1/1206/4/18/21/9
  • /ISO/3/6/1/4/1/1206/4/18/21/9
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/1206/transportation/18/21/rsuSpatStatus
  • /iso/identified-organization/dod/internet/private/enterprise/nema/transportation/18/21/rsuSpatStatus
  • /iso/identified-organization/dod/internet/private/enterprises/1206/transportation/18/21/rsuSpatStatus
  • /iso/identified-organization/dod/internet/private/enterprises/nema/transportation/18/21/rsuSpatStatus
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/1206/transportation/18/21/rsuSpatStatus
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/nema/transportation/18/21/rsuSpatStatus
  • /iso/identified-organization/dod/internet/private/vendor-objects/1206/transportation/18/21/rsuSpatStatus
  • /iso/identified-organization/dod/internet/private/vendor-objects/nema/transportation/18/21/rsuSpatStatus
  • /iso/org/dod/internet/private/enterprise/1206/transportation/18/21/rsuSpatStatus
  • /iso/org/dod/internet/private/enterprise/nema/transportation/18/21/rsuSpatStatus
  • /iso/org/dod/internet/private/enterprises/1206/transportation/18/21/rsuSpatStatus
  • /iso/org/dod/internet/private/enterprises/nema/transportation/18/21/rsuSpatStatus
  • /iso/org/dod/internet/private/ldap-enterprise/1206/transportation/18/21/rsuSpatStatus
  • /iso/org/dod/internet/private/ldap-enterprise/nema/transportation/18/21/rsuSpatStatus
  • /iso/org/dod/internet/private/vendor-objects/1206/transportation/18/21/rsuSpatStatus
  • /iso/org/dod/internet/private/vendor-objects/nema/transportation/18/21/rsuSpatStatus
  • Additional combinations skipped.

SNMP properties

Value type
BITS
Maximum access defined by MIB
read-write
Status in MIB
current

Bit values

Bit positionName
0manual
1stopTime
2failureFlash
3preempt
4priority
5fixedTime
6trafficDependent
7standby
8failureMode
12invalidMAP
13invalidSPaT

Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.

The displayed source records contain one distinct definition. Compare its source records.

rsuSpatStatus   OBJECT-TYPE
    SYNTAX        BITS{
                   manual(0),
                   stopTime(1),
                   failureFlash(2),
                   preempt(3),
                   priority(4),
                   fixedTime(5),
                   trafficDependent(6),
                   standby(7),
                   failureMode(8),
                   invalidMAP(12),
                   invalidSPaT(13) }
     MAX-ACCESS   read-write
     STATUS       current
     DESCRIPTION "<Definition> If a bit is enabled or active, the associated
          bit shall be set to (1). The definition of the term 'recent' is
          defined by the system in use. Bit 0 is equal to Bit 0 of the BIT
          STRING of DE_IntersectionStatusObject, Bit 1 is equal to Bit 1, etc.




                                                                                    

                                                                                      
                                                                                     

           Bit 0: Enabled when unitControlStatus is remoteManualControl (9) or
           localManualControl (10)
           Bit 1: Enabled when Bit 4: Stop Time in unitAlarmStatus2 is TRUE
           Bit 2: Enabled when unitFlashStatus is localManual (4), faultMonitor
           (5), or mmu (6). This bit may also be enabled if the preemptState is
           other(1) and indeterminate.
           Bit 3: Enabled when the preemptState for any preempt is any value
           other than notActive (2) or notActiveWithCall (3). This bit may also
           be enabled if the preemptState is other(1) and determinate.
           Bit 4: Enabled when the priorityStrategyRequestStatusInCO for any
           priority request is a value of requestQueued (2), or
           activeProcessing (4).
           Bit 5: Enabled if the CU is operating in fixedTime mode. This bit
           and bit 6 cannot both be simultaneously active (1).
           Bit 6: Enabled if the CU is operating in an actuated mode. This bit
           and bit 5 cannot both be simultaneously active (1).
           Bit 7: Enabled if the unitFlashStatus is automatic (3), startup (7),
           or preempt (8).
           Bit 8: Controller failure or failure in operation.
           Bit 9: Reserved. SET to 0.
           Bit 10: Reserved. SET to 1.
           Bit 11: Reserved. SET to 1.
           Bit 12: Enabled if the MAP message is invalid.
           Bit 13: Enabled if the SPaT message is invalid.
           Bits 14-15: Reserved

         The default bit value for Bits 10 and 11 is enabled (1). The default
         bit value for all other Bits is disabled (0).
         See Section 2.5 of RFC 3416 for encoding.
    <Object Identifier> 1.3.6.1.4.1.1206.4.18.21.9"
    REFERENCE "NTCIP 1202 spatStatus2 & SAE J2735
         DE_IntersectionStatusObject"
::= { rsuAscData 9 }

Meaning

Descriptions

1 unique

Identical descriptions are grouped. Different wording and device-specific notes are retained.

<Definition> If a bit is enabled or active, the associated bit shall be set to (1). The definition of the term 'recent' is defined by the system in use. Bit 0 is equal to Bit 0 of the BIT STRING of DE_IntersectionStatusObject, Bit 1 is equal to Bit 1, etc. Bit 0: Enabled when unitControlStatus is remoteManualControl (9) or localManualControl (10) Bit 1: Enabled when Bit 4: Stop Time in unitAlarmStatus2 is TRUE Bit 2: Enabled when unitFlashStatus is localManual (4), faultMonitor (5), or mmu (6). This bit may also be enabled if the preemptState is other(1) and indeterminate. Bit 3: Enabled when the preemptState for any preempt is any value other than notActive (2) or notActiveWithCall (3). This bit may also be enabled if the preemptState is other(1) and determinate. Bit 4: Enabled when the priorityStrategyRequestStatusInCO for any priority request is a value of requestQueued (2), or activeProcessing (4). Bit 5: Enabled if the CU is operating in fixedTime mode. This bit and bit 6 cannot both be simultaneously active (1). Bit 6: Enabled if the CU is operating in an actuated mode. This bit and bit 5 cannot both be simultaneously active (1). Bit 7: Enabled if the unitFlashStatus is automatic (3), startup (7), or preempt (8). Bit 8: Controller failure or failure in operation. Bit 9: Reserved. SET to 0. Bit 10: Reserved. SET to 1. Bit 11: Reserved. SET to 1. Bit 12: Enabled if the MAP message is invalid. Bit 13: Enabled if the SPaT message is invalid. Bits 14-15: Reserved The default bit value for Bits 10 and 11 is enabled (1). The default bit value for all other Bits is disabled (0). See Section 2.5 of RFC 3416 for encoding. <Object Identifier> 1.3.6.1.4.1.1206.4.18.21.9

Sources for this description

NTCIP published standard MIB annexes (reviewed modules)

See 1 matching source record

Evidence

Source records

1 records

Matching descriptions are grouped; open a group to compare definitions and supporting files.

Records for description 1NTCIP published standard MIB annexes (reviewed modules)1 record · 1 source

Description 1

rsuSpatStatus · unconfirmedNTCIP published standard MIB annexes (reviewed modules)1 source

Status in source: unconfirmed.

Names: rsuSpatStatus

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "rsuSpatStatus",
    "OBJECT-TYPE",
    "SYNTAX",
    "BITS",
    "{",
    "manual",
    "(",
    "0",
    ")",
    ",",
    "stopTime",
    "(",
    "1",
    ")",
    ",",
    "failureFlash",
    "(",
    "2",
    ")",
    ",",
    "preempt",
    "(",
    "3",
    ")",
    ",",
    "priority",
    "(",
    "4",
    ")",
    ",",
    "fixedTime",
    "(",
    "5",
    ")",
    ",",
    "trafficDependent",
    "(",
    "6",
    ")",
    ",",
    "standby",
    "(",
    "7",
    ")",
    ",",
    "failureMode",
    "(",
    "8",
    ")",
    ",",
    "invalidMAP",
    "(",
    "12",
    ")",
    ",",
    "invalidSPaT",
    "(",
    "13",
    ")",
    "}",
    "MAX-ACCESS",
    "read-write",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"<Definition> If a bit is enabled or active, the associated bit shall be set to (1). The definition of the term 'recent' is defined by the system in use. Bit 0 is equal to Bit 0 of the BIT STRING of DE_IntersectionStatusObject, Bit 1 is equal to Bit 1, etc. Bit 0: Enabled when unitControlStatus is remoteManualControl (9) or localManualControl (10) Bit 1: Enabled when Bit 4: Stop Time in unitAlarmStatus2 is TRUE Bit 2: Enabled when unitFlashStatus is localManual (4), faultMonitor (5), or mmu (6). This bit may also be enabled if the preemptState is other(1) and indeterminate. Bit 3: Enabled when the preemptState for any preempt is any value other than notActive (2) or notActiveWithCall (3). This bit may also be enabled if the preemptState is other(1) and determinate. Bit 4: Enabled when the priorityStrategyRequestStatusInCO for any priority request is a value of requestQueued (2), or activeProcessing (4). Bit 5: Enabled if the CU is operating in fixedTime mode. This bit and bit 6 cannot both be simultaneously active (1). Bit 6: Enabled if the CU is operating in an actuated mode. This bit and bit 5 cannot both be simultaneously active (1). Bit 7: Enabled if the unitFlashStatus is automatic (3), startup (7), or preempt (8). Bit 8: Controller failure or failure in operation. Bit 9: Reserved. SET to 0. Bit 10: Reserved. SET to 1. Bit 11: Reserved. SET to 1. Bit 12: Enabled if the MAP message is invalid. Bit 13: Enabled if the SPaT message is invalid. Bits 14-15: Reserved The default bit value for Bits 10 and 11 is enabled (1). The default bit value for all other Bits is disabled (0). See Section 2.5 of RFC 3416 for encoding. <Object Identifier> 1.3.6.1.4.1.1206.4.18.21.9\"",
    "REFERENCE",
    "\"NTCIP 1202 spatStatus2 & SAE J2735 DE_IntersectionStatusObject\"",
    "::=",
    "{",
    "rsuAscData",
    "9",
    "}"
  ],
  "syntax_tree": [
    [
      "BITS",
      [
        [
          "manual",
          0
        ],
        [
          "stopTime",
          1
        ],
        [
          "failureFlash",
          2
        ],
        [
          "preempt",
          3
        ],
        [
          "priority",
          4
        ],
        [
          "fixedTime",
          5
        ],
        [
          "trafficDependent",
          6
        ],
        [
          "standby",
          7
        ],
        [
          "failureMode",
          8
        ],
        [
          "invalidMAP",
          12
        ],
        [
          "invalidSPaT",
          13
        ]
      ]
    ],
    null,
    [
      "MaxAccessPart",
      "read-write"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "<Definition> If a bit is enabled or active, the associated bit shall be set to (1). The definition of the term 'recent' is defined by the system in use. Bit 0 is equal to Bit 0 of the BIT STRING of DE_IntersectionStatusObject, Bit 1 is equal to Bit 1, etc. Bit 0: Enabled when unitControlStatus is remoteManualControl (9) or localManualControl (10) Bit 1: Enabled when Bit 4: Stop Time in unitAlarmStatus2 is TRUE Bit 2: Enabled when unitFlashStatus is localManual (4), faultMonitor (5), or mmu (6). This bit may also be enabled if the preemptState is other(1) and indeterminate. Bit 3: Enabled when the preemptState for any preempt is any value other than notActive (2) or notActiveWithCall (3). This bit may also be enabled if the preemptState is other(1) and determinate. Bit 4: Enabled when the priorityStrategyRequestStatusInCO for any priority request is a value of requestQueued (2), or activeProcessing (4). Bit 5: Enabled if the CU is operating in fixedTime mode. This bit and bit 6 cannot both be simultaneously active (1). Bit 6: Enabled if the CU is operating in an actuated mode. This bit and bit 5 cannot both be simultaneously active (1). Bit 7: Enabled if the unitFlashStatus is automatic (3), startup (7), or preempt (8). Bit 8: Controller failure or failure in operation. Bit 9: Reserved. SET to 0. Bit 10: Reserved. SET to 1. Bit 11: Reserved. SET to 1. Bit 12: Enabled if the MAP message is invalid. Bit 13: Enabled if the SPaT message is invalid. Bits 14-15: Reserved The default bit value for Bits 10 and 11 is enabled (1). The default bit value for all other Bits is disabled (0). See Section 2.5 of RFC 3416 for encoding. <Object Identifier> 1.3.6.1.4.1.1206.4.18.21.9"
    ],
    [
      "REFERENCE",
      "NTCIP 1202 spatStatus2 & SAE J2735 DE_IntersectionStatusObject"
    ],
    null,
    null,
    null
  ]
}

Registration

Registration authorities

First Registration Authority (inferred from ancestor 1.3.6.1.4.1.1206)

Schopp Bruce J.

Siblings (3)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.1206.4.18.21.10 rsuSpatRoadAuthorityID00
1.3.6.1.4.1.1206.4.18.21.11 rsuSpatEnabledLanesStatus00
1.3.6.1.4.1.1206.4.18.21.13 1312