Status in source: mandatory.
Technical details
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"signatureMinDets",
"OBJECT-TYPE",
"SYNTAX",
"INTEGER",
"(",
"0",
".",
".",
"255",
")",
"ACCESS",
"read-write",
"STATUS",
"mandatory",
"DESCRIPTION",
"\" <Definition> This object defines the minimum number of operational sensors that constitute a valid input to the signature comparison routine. This value shall not exceed the maxSignatureDetectors object value. If the number of operational sensors falls below this value, timebaseOperationModeEnable and timebaseSpecFunctEnable shall assume a value of enabled. A value of ZERO prevents reverting to time base because of failed sensors. <Object Identifier> 1.3.6.1.4.1.1206.4.2.10.21.3.1.2\"",
"DEFVAL",
"{",
"2",
"}",
"::=",
"{",
"signatureConfigurationEntry",
"2",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"INTEGER",
[
"integerSubType",
[
[
0,
255
]
]
]
],
null,
[
"MaxAccessPart",
"read-write"
],
[
"Status",
"mandatory"
],
[
"DESCRIPTION",
"<Definition> This object defines the minimum number of operational sensors that constitute a valid input to the signature comparison routine. This value shall not exceed the maxSignatureDetectors object value. If the number of operational sensors falls below this value, timebaseOperationModeEnable and timebaseSpecFunctEnable shall assume a value of enabled. A value of ZERO prevents reverting to time base because of failed sensors. <Object Identifier> 1.3.6.1.4.1.1206.4.2.10.21.3.1.2"
],
null,
null,
null,
[
"DEFVAL",
2
]
]
}