OID reference

rsuIntTemp

1.3.6.1.4.1.1206.4.2.18.12.2

Description

<Definition> Contains the internal temperature of the RSU in degrees Celsius. A value of -101 indicates unknown. <Object Identifier> 1.3.6.1.4.1.1206.4.2.18.12.2

Full description and source information

Identification

Identifier and names

Parent
1.3.6.1.4.1.1206.4.2.18.12 (rsuSystemStats)
Node code
2
Node name
rsuIntTemp
Category
SNMP management object
Numeric OID
1.3.6.1.4.1.1206.4.2.18.12.2
URN notation
urn:oid:1.3.6.1.4.1.1206.4.2.18.12.2
ASN.1, OID-IRI and named path variants
ASN.1 notation

{1 3 6 1 4 1 1206 4 2 18 12 2}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) nema(1206) transportation(4) devices(2) rsu(18) rsuSystemStats(12) rsuIntTemp(2)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) nema(1206) transportation(4) devices(2) rsu(18) rsuSystemStats(12) rsuIntTemp(2)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) nema(1206) transportation(4) devices(2) rsu(18) rsuSystemStats(12) rsuIntTemp(2)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) nema(1206) transportation(4) devices(2) rsu(18) rsuSystemStats(12) rsuIntTemp(2)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) nema(1206) transportation(4) devices(2) rsu(18) rsuSystemStats(12) rsuIntTemp(2)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) nema(1206) transportation(4) devices(2) rsu(18) rsuSystemStats(12) rsuIntTemp(2)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) nema(1206) transportation(4) devices(2) rsu(18) rsuSystemStats(12) rsuIntTemp(2)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) nema(1206) transportation(4) devices(2) rsu(18) rsuSystemStats(12) rsuIntTemp(2)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprise(1) nema(1206) transportation(4) devices(2) rsu(18) rsuSystemStats(12) rsuIntTemp(2)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) nema(1206) transportation(4) devices(2) rsu(18) rsuSystemStats(12) rsuIntTemp(2)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) nema(1206) transportation(4) devices(2) rsu(18) rsuSystemStats(12) rsuIntTemp(2)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) nema(1206) transportation(4) devices(2) rsu(18) rsuSystemStats(12) rsuIntTemp(2)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) enterprise(1) nema(1206) transportation(4) devices(2) rsu(18) rsuSystemStats(12) rsuIntTemp(2)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) enterprises(1) nema(1206) transportation(4) devices(2) rsu(18) rsuSystemStats(12) rsuIntTemp(2)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) nema(1206) transportation(4) devices(2) rsu(18) rsuSystemStats(12) rsuIntTemp(2)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) vendor-objects(1) nema(1206) transportation(4) devices(2) rsu(18) rsuSystemStats(12) rsuIntTemp(2)}
OID-IRI notation
  • /1/3/6/1/4/1/1206/4/2/18/12/2
  • /ISO/Identified-Organization/6/1/4/1/1206/4/2/18/12/2
  • /ISO/3/6/1/4/1/1206/4/2/18/12/2
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/1206/transportation/devices/rsu/rsuSystemStats/rsuIntTemp
  • /iso/identified-organization/dod/internet/private/enterprise/nema/transportation/devices/rsu/rsuSystemStats/rsuIntTemp
  • /iso/identified-organization/dod/internet/private/enterprises/1206/transportation/devices/rsu/rsuSystemStats/rsuIntTemp
  • /iso/identified-organization/dod/internet/private/enterprises/nema/transportation/devices/rsu/rsuSystemStats/rsuIntTemp
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/1206/transportation/devices/rsu/rsuSystemStats/rsuIntTemp
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/nema/transportation/devices/rsu/rsuSystemStats/rsuIntTemp
  • /iso/identified-organization/dod/internet/private/vendor-objects/1206/transportation/devices/rsu/rsuSystemStats/rsuIntTemp
  • /iso/identified-organization/dod/internet/private/vendor-objects/nema/transportation/devices/rsu/rsuSystemStats/rsuIntTemp
  • /iso/org/dod/internet/private/enterprise/1206/transportation/devices/rsu/rsuSystemStats/rsuIntTemp
  • /iso/org/dod/internet/private/enterprise/nema/transportation/devices/rsu/rsuSystemStats/rsuIntTemp
  • /iso/org/dod/internet/private/enterprises/1206/transportation/devices/rsu/rsuSystemStats/rsuIntTemp
  • /iso/org/dod/internet/private/enterprises/nema/transportation/devices/rsu/rsuSystemStats/rsuIntTemp
  • /iso/org/dod/internet/private/ldap-enterprise/1206/transportation/devices/rsu/rsuSystemStats/rsuIntTemp
  • /iso/org/dod/internet/private/ldap-enterprise/nema/transportation/devices/rsu/rsuSystemStats/rsuIntTemp
  • /iso/org/dod/internet/private/vendor-objects/1206/transportation/devices/rsu/rsuSystemStats/rsuIntTemp
  • /iso/org/dod/internet/private/vendor-objects/nema/transportation/devices/rsu/rsuSystemStats/rsuIntTemp
  • Additional combinations skipped.

SNMP properties

Value type
Integer32
Units
degree Celsius, degrees Celsius
Maximum access defined by MIB
read-only
Status in MIB
current
Default value
-101

Definitions may combine these properties differently.

Compare 2 source variants

Variant 1 — NTCIP published standard MIB annexes (reviewed modules)

Value type
Integer32
Units
degree Celsius
Maximum access defined by MIB
read-only
Status in MIB
current
Default value
-101
Allowed ranges
-101–100

Variant 2 — NTCIP published standard MIB annexes (reviewed modules)

Value type
Integer32
Units
degrees Celsius
Maximum access defined by MIB
read-only
Status in MIB
current
Default value
-101
Allowed ranges
-101–100

Using this OID with SNMP

At least one MIB declaration places this object in a scalar group. A scalar instance uses the suffix .0.

snmpget [connection options] DEVICE .1.3.6.1.4.1.1206.4.2.18.12.2.0

Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.

Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.

Available source records contain 2 distinct definitions; some records may not include a definition.

Show 2 published definitions

rsuIntTemp · current

rsuIntTemp OBJECT-TYPE
    SYNTAX       Integer32 (-101..100)
    UNITS        "degree Celsius"
    MAX-ACCESS   read-only
    STATUS       current
    DESCRIPTION "<Definition> Contains the internal temperature of the RSU
        in degrees Celsius. A value of -101 indicates unknown.
    <Object Identifier> 1.3.6.1.4.1.1206.4.2.18.12.2"
    DEFVAL       { -101 }
::= { rsuSystemStats 2 }

rsuIntTemp · current

rsuIntTemp OBJECT-TYPE
    SYNTAX        Integer32 (-101..100)
    UNITS         "degrees Celsius"
    MAX-ACCESS    read-only
    STATUS        current
    DESCRIPTION "<Definition> Contains the internal temperature of the RSU
          in degrees Celsius. A value of -101 indicates unknown.
    <Object Identifier> 1.3.6.1.4.1.1206.4.2.18.12.2"
    DEFVAL { -101 }
::= { rsuSystemStats 2 }

Meaning

Descriptions

1 unique

Identical descriptions are grouped. Different wording and device-specific notes are retained.

<Definition> Contains the internal temperature of the RSU in degrees Celsius. A value of -101 indicates unknown. <Object Identifier> 1.3.6.1.4.1.1206.4.2.18.12.2

Sources for this description

NTCIP published standard MIB annexes (reviewed modules)

See 2 matching source records

Evidence

Source records

2 records

Matching descriptions are grouped; open a group to compare definitions and supporting files.

Records for description 1NTCIP published standard MIB annexes (reviewed modules)2 records · 2 sources

Description 1

rsuIntTemp · currentNTCIP published standard MIB annexes (reviewed modules)1 source

Status in source: current.

Names: rsuIntTemp

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "rsuIntTemp",
    "OBJECT-TYPE",
    "SYNTAX",
    "Integer32",
    "(",
    "-",
    "101",
    ".",
    ".",
    "100",
    ")",
    "UNITS",
    [
      "literal",
      "226465677265652043656c7369757322"
    ],
    "MAX-ACCESS",
    "read-only",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"<Definition> Contains the internal temperature of the RSU in degrees Celsius. A value of -101 indicates unknown. <Object Identifier> 1.3.6.1.4.1.1206.4.2.18.12.2\"",
    "DEFVAL",
    "{",
    "-",
    "101",
    "}",
    "::=",
    "{",
    "rsuSystemStats",
    "2",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "Integer32",
      [
        "integerSubType",
        [
          [
            -101,
            100
          ]
        ]
      ]
    ],
    [
      "UNITS",
      "degree Celsius"
    ],
    [
      "MaxAccessPart",
      "read-only"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "<Definition> Contains the internal temperature of the RSU in degrees Celsius. A value of -101 indicates unknown. <Object Identifier> 1.3.6.1.4.1.1206.4.2.18.12.2"
    ],
    null,
    null,
    null,
    [
      "DEFVAL",
      -101
    ]
  ]
}
rsuIntTemp · currentNTCIP published standard MIB annexes (reviewed modules)1 source

Status in source: current.

Names: rsuIntTemp

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "rsuIntTemp",
    "OBJECT-TYPE",
    "SYNTAX",
    "Integer32",
    "(",
    "-",
    "101",
    ".",
    ".",
    "100",
    ")",
    "UNITS",
    [
      "literal",
      "22646567726565732043656c7369757322"
    ],
    "MAX-ACCESS",
    "read-only",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"<Definition> Contains the internal temperature of the RSU in degrees Celsius. A value of -101 indicates unknown. <Object Identifier> 1.3.6.1.4.1.1206.4.2.18.12.2\"",
    "DEFVAL",
    "{",
    "-",
    "101",
    "}",
    "::=",
    "{",
    "rsuSystemStats",
    "2",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "Integer32",
      [
        "integerSubType",
        [
          [
            -101,
            100
          ]
        ]
      ]
    ],
    [
      "UNITS",
      "degrees Celsius"
    ],
    [
      "MaxAccessPart",
      "read-only"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "<Definition> Contains the internal temperature of the RSU in degrees Celsius. A value of -101 indicates unknown. <Object Identifier> 1.3.6.1.4.1.1206.4.2.18.12.2"
    ],
    null,
    null,
    null,
    [
      "DEFVAL",
      -101
    ]
  ]
}
  • NTCIP published standard MIB annexes (reviewed modules) · Publisher's source file: NTCIP 1218 v01A, Object Definitions for Roadside Units (RSUs) — original PDF · Official record

    Module: NTCIP1218-v01

    See published definition above

    Module imports
    {'SNMPv2-TC': ['TEXTUAL-CONVENTION', 'DateAndTime', 'RowStatus', 'DisplayString', 'MacAddress'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Integer32', 'Counter32', 'NOTIFICATION-TYPE', 'enterprises'], 'URI-TC-MIB': ['Uri255', 'Uri1024'], 'NTCIP8004v02': ['devices', 'OerString'], 'SYSLOG-TC-MIB': ['SyslogSeverity'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}

    Source data warning: Recovered from a file whose complete MIB does not parse. The original assignment and definition are preserved. Registration and implementation details may be inaccurate; consult the original file. Other damaged or unresolved declarations are not established registrations.

    Source data warning: This record is transcribed from a published NTCIP MIB annex. The downloadable text is a derived transcription with page furniture and section headings masked; the unmodified original PDF is authoritative. Native definitions, DESCRIPTION and STATUS are retained. A published object definition does not establish support by any particular device.

    Source data warning: Potentially inaccurate interpretation of historical NTCIP namespace references: NTCIP8004v02. These exact source files require the reviewed bindings shown below. The numeric roots used here are the explicit assignments in normative Annex A.2 of published NTCIP 8004 v02 (2010), physical pages 43–44. This does not establish that every historical module revision is identical. The annex also prints enterprise instead of RFC 1155 enterprises and declares Protocols while referencing protocols; those spelling interpretations are disclosed. The original IMPORTS, numeric suffixes and definitions remain unchanged. Verify both originals before implementation.

    · Download NTCIP-1218-v01A-2024-AsPublished.pdf — NTCIP1218-v01 (MIB transcription)

Registration

Registration authorities

First Registration Authority (inferred from ancestor 1.3.6.1.4.1.1206)

Schopp Bruce J.

Direct children (1)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.1206.4.2.18.12.2.1 111

Siblings (5)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.1206.4.2.18.12.1 rsuTimeSincePowerOn00
1.3.6.1.4.1.1206.4.2.18.12.3 rsuIntTempLowThreshold00
1.3.6.1.4.1.1206.4.2.18.12.4 rsuIntTempHighThreshold00
1.3.6.1.4.1.1206.4.2.18.12.5 maxRsuCommRange00
1.3.6.1.4.1.1206.4.2.18.12.6 rsuCommRangeTable113