OID reference

dmsActivateMessage

1.3.6.1.4.1.1206.4.2.3.6.3

Description

<Definition> A code indicating the active message. The value of this object may be SET by a management station or modified by logic internal to the DMS (e.g., activation of the end duration message, etc.). When modified by internal logic with a reference to a message ID code, the duration indicates 65535 (infinite), t…

Full description and source information

Identification

Identifier and names

Parent
1.3.6.1.4.1.1206.4.2.3.6 (signControl)
Node code
3
Node name
dmsActivateMessage
Category
SNMP management object
Numeric OID
1.3.6.1.4.1.1206.4.2.3.6.3
URN notation
urn:oid:1.3.6.1.4.1.1206.4.2.3.6.3
ASN.1, OID-IRI and named path variants
ASN.1 notation

{1 3 6 1 4 1 1206 4 2 3 6 3}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) nema(1206) transportation(4) devices(2) dms(3) signControl(6) dmsActivateMessage(3)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) nema(1206) transportation(4) devices(2) fontDefinition(3) signControl(6) dmsActivateMessage(3)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) nema(1206) transportation(4) devices(2) dms(3) signControl(6) dmsActivateMessage(3)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) nema(1206) transportation(4) devices(2) fontDefinition(3) signControl(6) dmsActivateMessage(3)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) nema(1206) transportation(4) devices(2) dms(3) signControl(6) dmsActivateMessage(3)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) nema(1206) transportation(4) devices(2) fontDefinition(3) signControl(6) dmsActivateMessage(3)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) nema(1206) transportation(4) devices(2) dms(3) signControl(6) dmsActivateMessage(3)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) nema(1206) transportation(4) devices(2) fontDefinition(3) signControl(6) dmsActivateMessage(3)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) nema(1206) transportation(4) devices(2) dms(3) signControl(6) dmsActivateMessage(3)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) nema(1206) transportation(4) devices(2) fontDefinition(3) signControl(6) dmsActivateMessage(3)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) nema(1206) transportation(4) devices(2) dms(3) signControl(6) dmsActivateMessage(3)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) nema(1206) transportation(4) devices(2) fontDefinition(3) signControl(6) dmsActivateMessage(3)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) nema(1206) transportation(4) devices(2) dms(3) signControl(6) dmsActivateMessage(3)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) nema(1206) transportation(4) devices(2) fontDefinition(3) signControl(6) dmsActivateMessage(3)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) nema(1206) transportation(4) devices(2) dms(3) signControl(6) dmsActivateMessage(3)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) nema(1206) transportation(4) devices(2) fontDefinition(3) signControl(6) dmsActivateMessage(3)}
  • Additional combinations skipped.
OID-IRI notation
  • /1/3/6/1/4/1/1206/4/2/3/6/3
  • /ISO/Identified-Organization/6/1/4/1/1206/4/2/3/6/3
  • /ISO/3/6/1/4/1/1206/4/2/3/6/3
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/1206/transportation/devices/dms/signControl/dmsActivateMessage
  • /iso/identified-organization/dod/internet/private/enterprise/1206/transportation/devices/fontDefinition/signControl/dmsActivateMessage
  • /iso/identified-organization/dod/internet/private/enterprise/nema/transportation/devices/dms/signControl/dmsActivateMessage
  • /iso/identified-organization/dod/internet/private/enterprise/nema/transportation/devices/fontDefinition/signControl/dmsActivateMessage
  • /iso/identified-organization/dod/internet/private/enterprises/1206/transportation/devices/dms/signControl/dmsActivateMessage
  • /iso/identified-organization/dod/internet/private/enterprises/1206/transportation/devices/fontDefinition/signControl/dmsActivateMessage
  • /iso/identified-organization/dod/internet/private/enterprises/nema/transportation/devices/dms/signControl/dmsActivateMessage
  • /iso/identified-organization/dod/internet/private/enterprises/nema/transportation/devices/fontDefinition/signControl/dmsActivateMessage
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/1206/transportation/devices/dms/signControl/dmsActivateMessage
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/1206/transportation/devices/fontDefinition/signControl/dmsActivateMessage
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/nema/transportation/devices/dms/signControl/dmsActivateMessage
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/nema/transportation/devices/fontDefinition/signControl/dmsActivateMessage
  • /iso/identified-organization/dod/internet/private/vendor-objects/1206/transportation/devices/dms/signControl/dmsActivateMessage
  • /iso/identified-organization/dod/internet/private/vendor-objects/1206/transportation/devices/fontDefinition/signControl/dmsActivateMessage
  • /iso/identified-organization/dod/internet/private/vendor-objects/nema/transportation/devices/dms/signControl/dmsActivateMessage
  • /iso/identified-organization/dod/internet/private/vendor-objects/nema/transportation/devices/fontDefinition/signControl/dmsActivateMessage
  • Additional combinations skipped.

SNMP properties

Value type
MessageActivationCode
Maximum access defined by MIB
read-write
Status in MIB
deprecated, mandatory

Definitions may combine these properties differently.

Compare 2 source variants

Variant 1 — ITE public NTCIP working repository MIBs

Value type
MessageActivationCode
Maximum access defined by MIB
read-write
Status in MIB
deprecated

Variant 2 — NTCIP published standard MIB annexes (reviewed modules), ITE public NTCIP working repository MIBs

Value type
MessageActivationCode
Maximum access defined by MIB
read-write
Status in MIB
mandatory

Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.

Available source records contain 5 distinct definitions; some records may not include a definition.

Show 5 published definitions

dmsActivateMessage · unconfirmed

dmsActivateMessage  OBJECT-TYPE 
SYNTAX      MessageActivationCode 
MAX-ACCESS  read-write 
STATUS      deprecated  
DESCRIPTION  
"<Definition> A code indicating the active message. The value of this object 
may be SET by a management station or modified by logic internal to the DMS 
(e.g., activation of the end duration message, etc.). 

When modified by internal logic with a reference to a message ID code, the 
duration indicates 65535 (infinite), the activate priority indicates 255, and 
the source address indicates an address of 127.0.0.1.

If a GET is performed on this object, the DMS shall respond with the value 
for the last message that was successfully activated.
The dmsActivateMsgError object shall be updated appropriately upon any 
attempt to update the value of this object, whether from an internal or 
external source.

If a message activation error occurs (e.g., dmsActivateMsgError is updated to 
a value other than 'none'), the new message shall not be activated and, if 
the activation request originated from a SET request, a genErr shall be 
returned. A management station should then GET the dmsActivateMsgError object 
as soon as possible to minimize the chance of additional activation attempts 
from overwriting the dmsActivateMsgError.

If a message is attempted to be activated via the scheduler or any internal 
message (e.g., end duration message, etc.) and the message to be activated 
contains an error, than the following objects shall be set to the appropriate 
values (as defined within these objects):
- dmsActivateMsgError,
- dmsActivateErrorMsgCode,
- dmsMultiSyntaxError,
- dmsMultiSyntaxErrorPosition (if supported),
- dmsMultiOtherErrorDescription (if supported),
- dmsDrumStatus (if supported)

A 'criticalTemperature' alarm shall have no effect on the 'activation' of a 
message, it will only affect the display of the active message. Thus, a 
message activation may occur during a 'criticalTemperature' alarm and the 
sign controller will behave as if the message is displayed. However, the 
shortErrorStatus will indicate a criticalTemperature alarm and the sign face 
illumination will be off. As soon as the DMS determines that the 
'criticalTemperature' alarm is no longer present, the DMS shall display the 
message stored in the currentBuffer. 

<Superseded by> dmsActivateMessageV4  
<Informative> This object was deprecated in NTCIP 1203 v04 in favor of 
MessageActivationCodeV4, which is designed to support IPv6 and to more 
securely record the source of the request.
<Parameter Type> Control
<Object Identifier> 1.3.6.1.4.1.1206.4.2.3.6.3"
::= { signControl 3 }

dmsActivateMessage · mandatory

dmsActivateMessage OBJECT-TYPE
SYNTAX           MessageActivationCode
ACCESS           read-write
STATUS           mandatory
DESCRIPTION “A code indicating the message which the sign shall activate. The dmsActivateMsgError
object shall be set appropriately when this object is SET. If a message activation error occurs, the new
message shall not be displayed and a GenErr shall be returned.”
::= {signControl 3}

dmsActivateMessage · mandatory

dmsActivateMessage OBJECT-TYPE
SYNTAX MessageActivationCode
ACCESS read-write
STATUS mandatory
DESCRIPTION
"<Definition> A code indicating the active message.   The value of this object



                                                                                         

Page 171                                                           NTCIP 1203 v02.35


may be SET by a management station or modified by logic internal to the DMS
(e.g., activation of the end duration message, etc.).

When modified by internal logic with a reference to a message ID code, the
duration will indicate 65535 (infinite), the activate priority will indicate
255, and the source address will indicate an address of 127.0.0.1.

If a GET is performed on this object, the DMS shall respond with the value
for the last message that was successfully activated.
The dmsActivateMsgError object shall be updated appropriately upon any
attempt to update the value of this object, whether from an internal or
external source.

If a message activation error occurs (e.g., dmsActivateMsgError is updated to
a value other than 'none'), the new message shall not be activated and, if
the activation request originated from a SET request, a genErr shall be
returned. A management station should then GET the dmsActivateMsgError
object as soon as possible to minimize the chance of additional activation
attempts from overwriting the dmsActivateMsgError.


If a message is attempted to be activated via the scheduler or any internal
message (e.g., end duration message, etc.) and the message to be activated
contains an error, than the following objects shall be set to the appropriate
values (as defined within these objects):
         − dmsActivateMsgError,
         − dmsActivateErrorMsgCode,
         − dmsMultiSyntaxError,
         − dmsMultiSyntaxErrorPosition (if supported),
         − dmsMultiOtherErrorDescription (if supported),
         − dmsDrumStatus (if supported)

A 'criticalTemperature' alarm shall have no effect on the 'activation' of a
message, it will only affect the display of the active message. Thus, a
message activation may occur during a 'criticalTemperature' alarm and the
sign controller will behave as if the message is displayed. However, the
shortErrorStatus will indicate a criticalTemperature alarm and the sign face
illumination will be off. As soon as the DMS determines that the
'criticalTemperature' alarm is no longer present, the DMS shall display the
message stored in the currentBuffer.

<Object Identifier> 1.3.6.1.4.1.1206.4.2.3.6.3"
::= { signControl 3 }

dmsActivateMessage · mandatory

dmsActivateMessage  OBJECT-TYPE
SYNTAX  MessageActivationCode
ACCESS  read-write
STATUS  mandatory
DESCRIPTION 
"<Definition> A code indicating the active message. The value of this object may be SET by a management station or modified by logic internal to the DMS (e.g., activation of the end duration message, etc.). 

When modified by internal logic with a reference to a message ID code, the duration indicates 65535 (infinite), the activate priority indicates 255, and the source address indicates an address of 127.0.0.1.

If a GET is performed on this object, the DMS shall respond with the value for the last message that was successfully activated.
The dmsActivateMsgError object shall be updated appropriately upon any attempt to update the value of this object, whether from an internal or external source.

If a message activation error occurs (e.g., dmsActivateMsgError is updated to a value other than 'none'), the new message shall not be activated and, if the activation request originated from a SET request, a genErr shall be returned. A management station should then GET the dmsActivateMsgError object as soon as possible to minimize the chance of additional activation attempts from overwriting the dmsActivateMsgError.

If a message is attempted to be activated via the scheduler or any internal message (e.g., end duration message, etc.) and the message to be activated contains an error, than the following objects shall be set to the appropriate values (as defined within these objects):
- dmsActivateMsgError,
- dmsActivateErrorMsgCode,
- dmsMultiSyntaxError,
- dmsMultiSyntaxErrorPosition (if supported),
- dmsMultiOtherErrorDescription (if supported),
- dmsDrumStatus (if supported)

A 'criticalTemperature' alarm shall have no effect on the 'activation' of a message, it will only affect the display of the active message. Thus, a message activation may occur during a 'criticalTemperature' alarm and the sign controller will behave as if the message is displayed. However, the shortErrorStatus will indicate a criticalTemperature alarm and the sign face illumination will be off. As soon as the DMS determines that the 'criticalTemperature' alarm is no longer present, the DMS shall display the message stored in the currentBuffer.

<Object Identifier> 1.3.6.1.4.1.1206.4.2.3.6.3"
::= { signControl 3 }

dmsActivateMessage · mandatory

dmsActivateMessage OBJECT-TYPE
SYNTAX MessageActivationCode
ACCESS read-write
STATUS mandatory


                                                                                         

                 
        

DESCRIPTION
"<Definition> A code indicating the active message. The value of this object
may be SET by a management station or modified by logic internal to the DMS
(e.g., activation of the end duration message, etc.).

When modified by internal logic with a reference to a message ID code, the
duration indicates 65535 (infinite), the activate priority indicates 255, and
the source address indicates an address of 127.0.0.1.

If a GET is performed on this object, the DMS shall respond with the value
for the last message that was successfully activated.
The dmsActivateMsgError object shall be updated appropriately upon any
attempt to update the value of this object, whether from an internal or
external source.

If a message activation error occurs (e.g., dmsActivateMsgError is updated to
a value other than 'none'), the new message shall not be activated and, if
the activation request originated from a SET request, a genErr shall be
returned. A management station should then GET the dmsActivateMsgError object
as soon as possible to minimize the chance of additional activation attempts
from overwriting the dmsActivateMsgError.

If a message is attempted to be activated via the scheduler or any internal
message (e.g., end duration message, etc.) and the message to be activated
contains an error, than the following objects shall be set to the appropriate
values (as defined within these objects):
            – dmsActivateMsgError,
            – dmsActivateErrorMsgCode,
            – dmsMultiSyntaxError,
            – dmsMultiSyntaxErrorPosition (if supported),
            – dmsMultiOtherErrorDescription (if supported),
            – dmsDrumStatus (if supported)

A 'criticalTemperature' alarm shall have no effect on the 'activation' of a
message, it will only affect the display of the active message. Thus, a
message activation may occur during a 'criticalTemperature' alarm and the
sign controller will behave as if the message is displayed. However, the
shortErrorStatus will indicate a criticalTemperature alarm and the sign face
illumination will be off. As soon as the DMS determines that the
'criticalTemperature' alarm is no longer present, the DMS shall display the
message stored in the currentBuffer.

<Object Identifier> 1.3.6.1.4.1.1206.4.2.3.6.3"
::= { signControl 3 }

Meaning

Descriptions

5 unique

Identical descriptions are grouped. Different wording and device-specific notes are retained.

Description 1

<Definition> A code indicating the active message. The value of this object may be SET by a management station or modified by logic internal to the DMS (e.g., activation of the end duration message, etc.). When modified by internal logic with a reference to a message ID code, the duration indicates 65535 (infinite), the activate priority indicates 255, and the source address indicates an address of 127.0.0.1. If a GET is performed on this object, the DMS shall respond with the value for the last message that was successfully activated. The dmsActivateMsgError object shall be updated appropriately upon any attempt to update the value of this object, whether from an internal or external source. If a message activation error occurs (e.g., dmsActivateMsgError is updated to a value other than 'none'), the new message shall not be activated and, if the activation request originated from a SET request, a genErr shall be returned. A management station should then GET the dmsActivateMsgError object as soon as possible to minimize the chance of additional activation attempts from overwriting the dmsActivateMsgError. If a message is attempted to be activated via the scheduler or any internal message (e.g., end duration message, etc.) and the message to be activated contains an error, than the following objects shall be set to the appropriate values (as defined within these objects): - dmsActivateMsgError, - dmsActivateErrorMsgCode, - dmsMultiSyntaxError, - dmsMultiSyntaxErrorPosition (if supported), - dmsMultiOtherErrorDescription (if supported), - dmsDrumStatus (if supported) A 'criticalTemperature' alarm shall have no effect on the 'activation' of a message, it will only affect the display of the active message. Thus, a message activation may occur during a 'criticalTemperature' alarm and the sign controller will behave as if the message is displayed. However, the shortErrorStatus will indicate a criticalTemperature alarm and the sign face illumination will be off. As soon as the DMS determines that the 'criticalTemperature' alarm is no longer present, the DMS shall display the message stored in the currentBuffer. <Superseded by> dmsActivateMessageV4 <Informative> This object was deprecated in NTCIP 1203 v04 in favor of MessageActivationCodeV4, which is designed to support IPv6 and to more securely record the source of the request. <Parameter Type> Control <Object Identifier> 1.3.6.1.4.1.1206.4.2.3.6.3

Sources for this description

ITE public NTCIP working repository MIBs

See 1 matching source record

Description 2

A code indicating the message which the sign shall activate. The dmsActivateMsgError object shall be set appropriately when this object is SET. If a message activation error occurs, the new message shall not be displayed and a GenErr shall be returned.

Sources for this description

NTCIP published standard MIB annexes (reviewed modules)

See 1 matching source record

Description 3

<Definition> A code indicating the active message. The value of this object Page 171 NTCIP 1203 v02.35 may be SET by a management station or modified by logic internal to the DMS (e.g., activation of the end duration message, etc.). When modified by internal logic with a reference to a message ID code, the duration will indicate 65535 (infinite), the activate priority will indicate 255, and the source address will indicate an address of 127.0.0.1. If a GET is performed on this object, the DMS shall respond with the value for the last message that was successfully activated. The dmsActivateMsgError object shall be updated appropriately upon any attempt to update the value of this object, whether from an internal or external source. If a message activation error occurs (e.g., dmsActivateMsgError is updated to a value other than 'none'), the new message shall not be activated and, if the activation request originated from a SET request, a genErr shall be returned. A management station should then GET the dmsActivateMsgError object as soon as possible to minimize the chance of additional activation attempts from overwriting the dmsActivateMsgError. If a message is attempted to be activated via the scheduler or any internal message (e.g., end duration message, etc.) and the message to be activated contains an error, than the following objects shall be set to the appropriate values (as defined within these objects): − dmsActivateMsgError, − dmsActivateErrorMsgCode, − dmsMultiSyntaxError, − dmsMultiSyntaxErrorPosition (if supported), − dmsMultiOtherErrorDescription (if supported), − dmsDrumStatus (if supported) A 'criticalTemperature' alarm shall have no effect on the 'activation' of a message, it will only affect the display of the active message. Thus, a message activation may occur during a 'criticalTemperature' alarm and the sign controller will behave as if the message is displayed. However, the shortErrorStatus will indicate a criticalTemperature alarm and the sign face illumination will be off. As soon as the DMS determines that the 'criticalTemperature' alarm is no longer present, the DMS shall display the message stored in the currentBuffer. <Object Identifier> 1.3.6.1.4.1.1206.4.2.3.6.3

Sources for this description

NTCIP published standard MIB annexes (reviewed modules)

See 1 matching source record

Description 4

<Definition> A code indicating the active message. The value of this object may be SET by a management station or modified by logic internal to the DMS (e.g., activation of the end duration message, etc.). When modified by internal logic with a reference to a message ID code, the duration indicates 65535 (infinite), the activate priority indicates 255, and the source address indicates an address of 127.0.0.1. If a GET is performed on this object, the DMS shall respond with the value for the last message that was successfully activated. The dmsActivateMsgError object shall be updated appropriately upon any attempt to update the value of this object, whether from an internal or external source. If a message activation error occurs (e.g., dmsActivateMsgError is updated to a value other than 'none'), the new message shall not be activated and, if the activation request originated from a SET request, a genErr shall be returned. A management station should then GET the dmsActivateMsgError object as soon as possible to minimize the chance of additional activation attempts from overwriting the dmsActivateMsgError. If a message is attempted to be activated via the scheduler or any internal message (e.g., end duration message, etc.) and the message to be activated contains an error, than the following objects shall be set to the appropriate values (as defined within these objects): - dmsActivateMsgError, - dmsActivateErrorMsgCode, - dmsMultiSyntaxError, - dmsMultiSyntaxErrorPosition (if supported), - dmsMultiOtherErrorDescription (if supported), - dmsDrumStatus (if supported) A 'criticalTemperature' alarm shall have no effect on the 'activation' of a message, it will only affect the display of the active message. Thus, a message activation may occur during a 'criticalTemperature' alarm and the sign controller will behave as if the message is displayed. However, the shortErrorStatus will indicate a criticalTemperature alarm and the sign face illumination will be off. As soon as the DMS determines that the 'criticalTemperature' alarm is no longer present, the DMS shall display the message stored in the currentBuffer. <Object Identifier> 1.3.6.1.4.1.1206.4.2.3.6.3

Sources for this description

ITE public NTCIP working repository MIBs

See 1 matching source record

Description 5

<Definition> A code indicating the active message. The value of this object may be SET by a management station or modified by logic internal to the DMS (e.g., activation of the end duration message, etc.). When modified by internal logic with a reference to a message ID code, the duration indicates 65535 (infinite), the activate priority indicates 255, and the source address indicates an address of 127.0.0.1. If a GET is performed on this object, the DMS shall respond with the value for the last message that was successfully activated. The dmsActivateMsgError object shall be updated appropriately upon any attempt to update the value of this object, whether from an internal or external source. If a message activation error occurs (e.g., dmsActivateMsgError is updated to a value other than 'none'), the new message shall not be activated and, if the activation request originated from a SET request, a genErr shall be returned. A management station should then GET the dmsActivateMsgError object as soon as possible to minimize the chance of additional activation attempts from overwriting the dmsActivateMsgError. If a message is attempted to be activated via the scheduler or any internal message (e.g., end duration message, etc.) and the message to be activated contains an error, than the following objects shall be set to the appropriate values (as defined within these objects): – dmsActivateMsgError, – dmsActivateErrorMsgCode, – dmsMultiSyntaxError, – dmsMultiSyntaxErrorPosition (if supported), – dmsMultiOtherErrorDescription (if supported), – dmsDrumStatus (if supported) A 'criticalTemperature' alarm shall have no effect on the 'activation' of a message, it will only affect the display of the active message. Thus, a message activation may occur during a 'criticalTemperature' alarm and the sign controller will behave as if the message is displayed. However, the shortErrorStatus will indicate a criticalTemperature alarm and the sign face illumination will be off. As soon as the DMS determines that the 'criticalTemperature' alarm is no longer present, the DMS shall display the message stored in the currentBuffer. <Object Identifier> 1.3.6.1.4.1.1206.4.2.3.6.3

Sources for this description

NTCIP published standard MIB annexes (reviewed modules)

See 1 matching source record

Evidence

Source records

5 records

Matching descriptions are grouped; open a group to compare definitions and supporting files.

Records for description 1ITE public NTCIP working repository MIBs1 record · 1 source

Description 1

dmsActivateMessage · unconfirmedITE public NTCIP working repository MIBs1 source

Status in source: unconfirmed.

Names: dmsActivateMessage

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "dmsActivateMessage",
    "OBJECT-TYPE",
    "SYNTAX",
    "MessageActivationCode",
    "MAX-ACCESS",
    "read-write",
    "STATUS",
    "deprecated",
    "DESCRIPTION",
    "\"<Definition> A code indicating the active message. The value of this object may be SET by a management station or modified by logic internal to the DMS (e.g., activation of the end duration message, etc.). When modified by internal logic with a reference to a message ID code, the duration indicates 65535 (infinite), the activate priority indicates 255, and the source address indicates an address of 127.0.0.1. If a GET is performed on this object, the DMS shall respond with the value for the last message that was successfully activated. The dmsActivateMsgError object shall be updated appropriately upon any attempt to update the value of this object, whether from an internal or external source. If a message activation error occurs (e.g., dmsActivateMsgError is updated to a value other than 'none'), the new message shall not be activated and, if the activation request originated from a SET request, a genErr shall be returned. A management station should then GET the dmsActivateMsgError object as soon as possible to minimize the chance of additional activation attempts from overwriting the dmsActivateMsgError. If a message is attempted to be activated via the scheduler or any internal message (e.g., end duration message, etc.) and the message to be activated contains an error, than the following objects shall be set to the appropriate values (as defined within these objects): - dmsActivateMsgError, - dmsActivateErrorMsgCode, - dmsMultiSyntaxError, - dmsMultiSyntaxErrorPosition (if supported), - dmsMultiOtherErrorDescription (if supported), - dmsDrumStatus (if supported) A 'criticalTemperature' alarm shall have no effect on the 'activation' of a message, it will only affect the display of the active message. Thus, a message activation may occur during a 'criticalTemperature' alarm and the sign controller will behave as if the message is displayed. However, the shortErrorStatus will indicate a criticalTemperature alarm and the sign face illumination will be off. As soon as the DMS determines that the 'criticalTemperature' alarm is no longer present, the DMS shall display the message stored in the currentBuffer. <Superseded by> dmsActivateMessageV4 <Informative> This object was deprecated in NTCIP 1203 v04 in favor of MessageActivationCodeV4, which is designed to support IPv6 and to more securely record the source of the request. <Parameter Type> Control <Object Identifier> 1.3.6.1.4.1.1206.4.2.3.6.3\"",
    "::=",
    "{",
    "signControl",
    "3",
    "}"
  ],
  "syntax_tree": [
    [
      "row",
      "MessageActivationCode"
    ],
    null,
    [
      "MaxAccessPart",
      "read-write"
    ],
    [
      "Status",
      "deprecated"
    ],
    [
      "DESCRIPTION",
      "<Definition> A code indicating the active message. The value of this object may be SET by a management station or modified by logic internal to the DMS (e.g., activation of the end duration message, etc.). When modified by internal logic with a reference to a message ID code, the duration indicates 65535 (infinite), the activate priority indicates 255, and the source address indicates an address of 127.0.0.1. If a GET is performed on this object, the DMS shall respond with the value for the last message that was successfully activated. The dmsActivateMsgError object shall be updated appropriately upon any attempt to update the value of this object, whether from an internal or external source. If a message activation error occurs (e.g., dmsActivateMsgError is updated to a value other than 'none'), the new message shall not be activated and, if the activation request originated from a SET request, a genErr shall be returned. A management station should then GET the dmsActivateMsgError object as soon as possible to minimize the chance of additional activation attempts from overwriting the dmsActivateMsgError. If a message is attempted to be activated via the scheduler or any internal message (e.g., end duration message, etc.) and the message to be activated contains an error, than the following objects shall be set to the appropriate values (as defined within these objects): - dmsActivateMsgError, - dmsActivateErrorMsgCode, - dmsMultiSyntaxError, - dmsMultiSyntaxErrorPosition (if supported), - dmsMultiOtherErrorDescription (if supported), - dmsDrumStatus (if supported) A 'criticalTemperature' alarm shall have no effect on the 'activation' of a message, it will only affect the display of the active message. Thus, a message activation may occur during a 'criticalTemperature' alarm and the sign controller will behave as if the message is displayed. However, the shortErrorStatus will indicate a criticalTemperature alarm and the sign face illumination will be off. As soon as the DMS determines that the 'criticalTemperature' alarm is no longer present, the DMS shall display the message stored in the currentBuffer. <Superseded by> dmsActivateMessageV4 <Informative> This object was deprecated in NTCIP 1203 v04 in favor of MessageActivationCodeV4, which is designed to support IPv6 and to more securely record the source of the request. <Parameter Type> Control <Object Identifier> 1.3.6.1.4.1.1206.4.2.3.6.3"
    ],
    null,
    null,
    null,
    null
  ]
}
  • ITE public NTCIP working repository MIBs · Publisher's source file: NTCIP-1203 — NTCIP1203-Dms.mib

    Module: NTCIP1203-Dms

    See published definition above

    Module imports
    {'SNMPv2-TC': ['TEXTUAL-CONVENTION', 'DisplayString', 'StorageType', 'RowStatus'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-IDENTITY', 'OBJECT-TYPE', 'Integer32', 'Unsigned32', 'Counter32', 'IpAddress'], 'SNMPv2-CONF': ['OBJECT-GROUP'], 'ISO26048-1-Srsa': ['fdSrsaTypeCode', 'fdSrsaPortIndex'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString'], 'ISO26048-1-Global-TC': ['ITSDirection', 'ITSInteger8', 'ITSLatitude84', 'ITSLongitude84', 'ITSBitmap'], 'TRANSPORT-ADDRESS-MIB': ['TransportAddressType', 'TransportAddress'], 'NTCIP8004-Transportation': ['NtcipOwnerString', 'NtcipIntegerBitmap8', 'NtcipIntegerBitmap16', 'NtcipTwoColors', 'devices']}

    Source data warning: This original is published in an ITE NTCIP working repository. Repository publication does not establish that this particular revision is an adopted standard. Consult its native revision history and the NTCIP published standards catalog before implementation. Copyright and distribution notices are retained in the downloadable original.

    Source data warning: Published module-root disagreement: dms has an SMI assignment resolving to 1.3.6.1.4.1.1206.4.2.6, while its DESCRIPTION explicitly prints 1.3.6.1.4.1.1206.4.2.3. All dependent assignments from this module require verification. No root number has been silently corrected.

    Source data warning: Published source disagreement: this literal SMI assignment resolves to 1.3.6.1.4.1.1206.4.2.6.6.3, but its DESCRIPTION explicitly lists 1.3.6.1.4.1.1206.4.2.3.6.3. Both published numeric claims are retained as unconfirmed evidence. Neither value is presented as a verified correction or an independently confirmed registration; consult the original file and the applicable standard edition.

    · Download NTCIP-1203 — NTCIP1203-Dms.mib
Records for description 2NTCIP published standard MIB annexes (reviewed modules)1 record · 1 source

Description 2

dmsActivateMessage · mandatoryNTCIP published standard MIB annexes (reviewed modules)1 source

Status in source: mandatory.

Names: dmsActivateMessage

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "dmsActivateMessage",
    "OBJECT-TYPE",
    "SYNTAX",
    "MessageActivationCode",
    "ACCESS",
    "read-write",
    "STATUS",
    "mandatory",
    "DESCRIPTION",
    "“",
    "A",
    "code",
    "indicating",
    "the",
    "message",
    "which",
    "the",
    "sign",
    "shall",
    "activate",
    ".",
    "The",
    "dmsActivateMsgError",
    "object",
    "shall",
    "be",
    "set",
    "appropriately",
    "when",
    "this",
    "object",
    "is",
    "SET",
    ".",
    "If",
    "a",
    "message",
    "activation",
    "error",
    "occurs",
    ",",
    "the",
    "new",
    "message",
    "shall",
    "not",
    "be",
    "displayed",
    "and",
    "a",
    "GenErr",
    "shall",
    "be",
    "returned",
    ".",
    "”",
    "::=",
    "{",
    "signControl",
    "3",
    "}"
  ],
  "syntax_tree": [
    [
      "row",
      "MessageActivationCode"
    ],
    null,
    [
      "MaxAccessPart",
      "read-write"
    ],
    [
      "Status",
      "mandatory"
    ],
    [
      "DESCRIPTION",
      "A code indicating the message which the sign shall activate. The dmsActivateMsgError object shall be set appropriately when this object is SET. If a message activation error occurs, the new message shall not be displayed and a GenErr shall be returned."
    ],
    null,
    null,
    null,
    null
  ]
}
Records for description 3NTCIP published standard MIB annexes (reviewed modules)1 record · 1 source

Description 3

dmsActivateMessage · mandatoryNTCIP published standard MIB annexes (reviewed modules)1 source

Status in source: mandatory.

Names: dmsActivateMessage

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "dmsActivateMessage",
    "OBJECT-TYPE",
    "SYNTAX",
    "MessageActivationCode",
    "ACCESS",
    "read-write",
    "STATUS",
    "mandatory",
    "DESCRIPTION",
    "\"<Definition> A code indicating the active message. The value of this object Page 171 NTCIP 1203 v02.35 may be SET by a management station or modified by logic internal to the DMS (e.g., activation of the end duration message, etc.). When modified by internal logic with a reference to a message ID code, the duration will indicate 65535 (infinite), the activate priority will indicate 255, and the source address will indicate an address of 127.0.0.1. If a GET is performed on this object, the DMS shall respond with the value for the last message that was successfully activated. The dmsActivateMsgError object shall be updated appropriately upon any attempt to update the value of this object, whether from an internal or external source. If a message activation error occurs (e.g., dmsActivateMsgError is updated to a value other than 'none'), the new message shall not be activated and, if the activation request originated from a SET request, a genErr shall be returned. A management station should then GET the dmsActivateMsgError object as soon as possible to minimize the chance of additional activation attempts from overwriting the dmsActivateMsgError. If a message is attempted to be activated via the scheduler or any internal message (e.g., end duration message, etc.) and the message to be activated contains an error, than the following objects shall be set to the appropriate values (as defined within these objects): − dmsActivateMsgError, − dmsActivateErrorMsgCode, − dmsMultiSyntaxError, − dmsMultiSyntaxErrorPosition (if supported), − dmsMultiOtherErrorDescription (if supported), − dmsDrumStatus (if supported) A 'criticalTemperature' alarm shall have no effect on the 'activation' of a message, it will only affect the display of the active message. Thus, a message activation may occur during a 'criticalTemperature' alarm and the sign controller will behave as if the message is displayed. However, the shortErrorStatus will indicate a criticalTemperature alarm and the sign face illumination will be off. As soon as the DMS determines that the 'criticalTemperature' alarm is no longer present, the DMS shall display the message stored in the currentBuffer. <Object Identifier> 1.3.6.1.4.1.1206.4.2.3.6.3\"",
    "::=",
    "{",
    "signControl",
    "3",
    "}"
  ],
  "syntax_tree": [
    [
      "row",
      "MessageActivationCode"
    ],
    null,
    [
      "MaxAccessPart",
      "read-write"
    ],
    [
      "Status",
      "mandatory"
    ],
    [
      "DESCRIPTION",
      "<Definition> A code indicating the active message. The value of this object Page 171 NTCIP 1203 v02.35 may be SET by a management station or modified by logic internal to the DMS (e.g., activation of the end duration message, etc.). When modified by internal logic with a reference to a message ID code, the duration will indicate 65535 (infinite), the activate priority will indicate 255, and the source address will indicate an address of 127.0.0.1. If a GET is performed on this object, the DMS shall respond with the value for the last message that was successfully activated. The dmsActivateMsgError object shall be updated appropriately upon any attempt to update the value of this object, whether from an internal or external source. If a message activation error occurs (e.g., dmsActivateMsgError is updated to a value other than 'none'), the new message shall not be activated and, if the activation request originated from a SET request, a genErr shall be returned. A management station should then GET the dmsActivateMsgError object as soon as possible to minimize the chance of additional activation attempts from overwriting the dmsActivateMsgError. If a message is attempted to be activated via the scheduler or any internal message (e.g., end duration message, etc.) and the message to be activated contains an error, than the following objects shall be set to the appropriate values (as defined within these objects): − dmsActivateMsgError, − dmsActivateErrorMsgCode, − dmsMultiSyntaxError, − dmsMultiSyntaxErrorPosition (if supported), − dmsMultiOtherErrorDescription (if supported), − dmsDrumStatus (if supported) A 'criticalTemperature' alarm shall have no effect on the 'activation' of a message, it will only affect the display of the active message. Thus, a message activation may occur during a 'criticalTemperature' alarm and the sign controller will behave as if the message is displayed. However, the shortErrorStatus will indicate a criticalTemperature alarm and the sign face illumination will be off. As soon as the DMS determines that the 'criticalTemperature' alarm is no longer present, the DMS shall display the message stored in the currentBuffer. <Object Identifier> 1.3.6.1.4.1.1206.4.2.3.6.3"
    ],
    null,
    null,
    null,
    null
  ]
}
Records for description 4ITE public NTCIP working repository MIBs1 record · 1 source

Description 4

dmsActivateMessage · mandatoryITE public NTCIP working repository MIBs1 source

Status in source: mandatory.

Names: dmsActivateMessage

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "dmsActivateMessage",
    "OBJECT-TYPE",
    "SYNTAX",
    "MessageActivationCode",
    "ACCESS",
    "read-write",
    "STATUS",
    "mandatory",
    "DESCRIPTION",
    "\"<Definition> A code indicating the active message. The value of this object may be SET by a management station or modified by logic internal to the DMS (e.g., activation of the end duration message, etc.). When modified by internal logic with a reference to a message ID code, the duration indicates 65535 (infinite), the activate priority indicates 255, and the source address indicates an address of 127.0.0.1. If a GET is performed on this object, the DMS shall respond with the value for the last message that was successfully activated. The dmsActivateMsgError object shall be updated appropriately upon any attempt to update the value of this object, whether from an internal or external source. If a message activation error occurs (e.g., dmsActivateMsgError is updated to a value other than 'none'), the new message shall not be activated and, if the activation request originated from a SET request, a genErr shall be returned. A management station should then GET the dmsActivateMsgError object as soon as possible to minimize the chance of additional activation attempts from overwriting the dmsActivateMsgError. If a message is attempted to be activated via the scheduler or any internal message (e.g., end duration message, etc.) and the message to be activated contains an error, than the following objects shall be set to the appropriate values (as defined within these objects): - dmsActivateMsgError, - dmsActivateErrorMsgCode, - dmsMultiSyntaxError, - dmsMultiSyntaxErrorPosition (if supported), - dmsMultiOtherErrorDescription (if supported), - dmsDrumStatus (if supported) A 'criticalTemperature' alarm shall have no effect on the 'activation' of a message, it will only affect the display of the active message. Thus, a message activation may occur during a 'criticalTemperature' alarm and the sign controller will behave as if the message is displayed. However, the shortErrorStatus will indicate a criticalTemperature alarm and the sign face illumination will be off. As soon as the DMS determines that the 'criticalTemperature' alarm is no longer present, the DMS shall display the message stored in the currentBuffer. <Object Identifier> 1.3.6.1.4.1.1206.4.2.3.6.3\"",
    "::=",
    "{",
    "signControl",
    "3",
    "}"
  ],
  "syntax_tree": [
    [
      "row",
      "MessageActivationCode"
    ],
    null,
    [
      "MaxAccessPart",
      "read-write"
    ],
    [
      "Status",
      "mandatory"
    ],
    [
      "DESCRIPTION",
      "<Definition> A code indicating the active message. The value of this object may be SET by a management station or modified by logic internal to the DMS (e.g., activation of the end duration message, etc.). When modified by internal logic with a reference to a message ID code, the duration indicates 65535 (infinite), the activate priority indicates 255, and the source address indicates an address of 127.0.0.1. If a GET is performed on this object, the DMS shall respond with the value for the last message that was successfully activated. The dmsActivateMsgError object shall be updated appropriately upon any attempt to update the value of this object, whether from an internal or external source. If a message activation error occurs (e.g., dmsActivateMsgError is updated to a value other than 'none'), the new message shall not be activated and, if the activation request originated from a SET request, a genErr shall be returned. A management station should then GET the dmsActivateMsgError object as soon as possible to minimize the chance of additional activation attempts from overwriting the dmsActivateMsgError. If a message is attempted to be activated via the scheduler or any internal message (e.g., end duration message, etc.) and the message to be activated contains an error, than the following objects shall be set to the appropriate values (as defined within these objects): - dmsActivateMsgError, - dmsActivateErrorMsgCode, - dmsMultiSyntaxError, - dmsMultiSyntaxErrorPosition (if supported), - dmsMultiOtherErrorDescription (if supported), - dmsDrumStatus (if supported) A 'criticalTemperature' alarm shall have no effect on the 'activation' of a message, it will only affect the display of the active message. Thus, a message activation may occur during a 'criticalTemperature' alarm and the sign controller will behave as if the message is displayed. However, the shortErrorStatus will indicate a criticalTemperature alarm and the sign face illumination will be off. As soon as the DMS determines that the 'criticalTemperature' alarm is no longer present, the DMS shall display the message stored in the currentBuffer. <Object Identifier> 1.3.6.1.4.1.1206.4.2.3.6.3"
    ],
    null,
    null,
    null,
    null
  ]
}
  • ITE public NTCIP working repository MIBs · Publisher's source file: NTCIP_1203 — v03/1203v03A-06g.mib

    Module: NTCIP1203-v0305

    See published definition above

    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC1155-SMI': ['IpAddress', 'Counter'], 'RFC1213-MIB': ['DisplayString'], 'NTCIP8004v02': ['OwnerString', 'dms']}

    Source data warning: This original is published in an ITE NTCIP working repository. Repository publication does not establish that this particular revision is an adopted standard. Consult its native revision history and the NTCIP published standards catalog before implementation. Copyright and distribution notices are retained in the downloadable original.

    Source data warning: Potentially inaccurate interpretation of historical NTCIP imports: the original references NTCIP8004v02, which is absent from the public repository snapshot. The numeric roots used here are the explicit assignments in normative Annex A.2 of published NTCIP 8004 v02 (2010), physical pages 43–44. This does not establish that every historical module revision is identical. The annex also prints enterprise instead of RFC 1155 enterprises and declares Protocols while referencing protocols; those spelling interpretations are disclosed. The original IMPORTS, numeric suffixes and definitions remain unchanged. Verify both originals before implementation.

    · Download NTCIP_1203 — v03/1203v03A-06g.mib
Records for description 5NTCIP published standard MIB annexes (reviewed modules)1 record · 1 source

Description 5

dmsActivateMessage · mandatoryNTCIP published standard MIB annexes (reviewed modules)1 source

Status in source: mandatory.

Names: dmsActivateMessage

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "dmsActivateMessage",
    "OBJECT-TYPE",
    "SYNTAX",
    "MessageActivationCode",
    "ACCESS",
    "read-write",
    "STATUS",
    "mandatory",
    "DESCRIPTION",
    "\"<Definition> A code indicating the active message. The value of this object may be SET by a management station or modified by logic internal to the DMS (e.g., activation of the end duration message, etc.). When modified by internal logic with a reference to a message ID code, the duration indicates 65535 (infinite), the activate priority indicates 255, and the source address indicates an address of 127.0.0.1. If a GET is performed on this object, the DMS shall respond with the value for the last message that was successfully activated. The dmsActivateMsgError object shall be updated appropriately upon any attempt to update the value of this object, whether from an internal or external source. If a message activation error occurs (e.g., dmsActivateMsgError is updated to a value other than 'none'), the new message shall not be activated and, if the activation request originated from a SET request, a genErr shall be returned. A management station should then GET the dmsActivateMsgError object as soon as possible to minimize the chance of additional activation attempts from overwriting the dmsActivateMsgError. If a message is attempted to be activated via the scheduler or any internal message (e.g., end duration message, etc.) and the message to be activated contains an error, than the following objects shall be set to the appropriate values (as defined within these objects): – dmsActivateMsgError, – dmsActivateErrorMsgCode, – dmsMultiSyntaxError, – dmsMultiSyntaxErrorPosition (if supported), – dmsMultiOtherErrorDescription (if supported), – dmsDrumStatus (if supported) A 'criticalTemperature' alarm shall have no effect on the 'activation' of a message, it will only affect the display of the active message. Thus, a message activation may occur during a 'criticalTemperature' alarm and the sign controller will behave as if the message is displayed. However, the shortErrorStatus will indicate a criticalTemperature alarm and the sign face illumination will be off. As soon as the DMS determines that the 'criticalTemperature' alarm is no longer present, the DMS shall display the message stored in the currentBuffer. <Object Identifier> 1.3.6.1.4.1.1206.4.2.3.6.3\"",
    "::=",
    "{",
    "signControl",
    "3",
    "}"
  ],
  "syntax_tree": [
    [
      "row",
      "MessageActivationCode"
    ],
    null,
    [
      "MaxAccessPart",
      "read-write"
    ],
    [
      "Status",
      "mandatory"
    ],
    [
      "DESCRIPTION",
      "<Definition> A code indicating the active message. The value of this object may be SET by a management station or modified by logic internal to the DMS (e.g., activation of the end duration message, etc.). When modified by internal logic with a reference to a message ID code, the duration indicates 65535 (infinite), the activate priority indicates 255, and the source address indicates an address of 127.0.0.1. If a GET is performed on this object, the DMS shall respond with the value for the last message that was successfully activated. The dmsActivateMsgError object shall be updated appropriately upon any attempt to update the value of this object, whether from an internal or external source. If a message activation error occurs (e.g., dmsActivateMsgError is updated to a value other than 'none'), the new message shall not be activated and, if the activation request originated from a SET request, a genErr shall be returned. A management station should then GET the dmsActivateMsgError object as soon as possible to minimize the chance of additional activation attempts from overwriting the dmsActivateMsgError. If a message is attempted to be activated via the scheduler or any internal message (e.g., end duration message, etc.) and the message to be activated contains an error, than the following objects shall be set to the appropriate values (as defined within these objects): – dmsActivateMsgError, – dmsActivateErrorMsgCode, – dmsMultiSyntaxError, – dmsMultiSyntaxErrorPosition (if supported), – dmsMultiOtherErrorDescription (if supported), – dmsDrumStatus (if supported) A 'criticalTemperature' alarm shall have no effect on the 'activation' of a message, it will only affect the display of the active message. Thus, a message activation may occur during a 'criticalTemperature' alarm and the sign controller will behave as if the message is displayed. However, the shortErrorStatus will indicate a criticalTemperature alarm and the sign face illumination will be off. As soon as the DMS determines that the 'criticalTemperature' alarm is no longer present, the DMS shall display the message stored in the currentBuffer. <Object Identifier> 1.3.6.1.4.1.1206.4.2.3.6.3"
    ],
    null,
    null,
    null,
    null
  ]
}
  • NTCIP published standard MIB annexes (reviewed modules) · Publisher's source file: NTCIP 1203 v03, Object Definitions for Dynamic Message Signs (DMS) Published September 2014 — original PDF · Official record

    Module: NTCIP1203-v03-05

    See published definition above

    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'NTCIP8004': ['OwnerString', 'dms'], 'RFC1155-SMI': ['IpAddress', 'Counter'], 'RFC1213-MIB': ['DisplayString']}

    Source data warning: Recovered from a file whose complete MIB does not parse. The original assignment and definition are preserved. Registration and implementation details may be inaccurate; consult the original file. Other damaged or unresolved declarations are not established registrations.

    Source data warning: This record is transcribed from a published NTCIP MIB annex. The downloadable text is a derived transcription with page furniture and section headings masked; the unmodified original PDF is authoritative. Native definitions, DESCRIPTION and STATUS are retained. A published object definition does not establish support by any particular device.

    Source data warning: The PDF prints an invalid ASN.1 module label (NTCIP1203 v03.05). The derived transcription uses an equal-length internal parsing label; this is not an OID registration or an alteration of any numeric assignment. The original label and full PDF are retained.

    Source data warning: Potentially inaccurate interpretation of historical NTCIP namespace references: NTCIP8004. These exact source files require the reviewed bindings shown below. The numeric roots used here are the explicit assignments in normative Annex A.2 of published NTCIP 8004 v02 (2010), physical pages 43–44. This does not establish that every historical module revision is identical. The annex also prints enterprise instead of RFC 1155 enterprises and declares Protocols while referencing protocols; those spelling interpretations are disclosed. The original IMPORTS, numeric suffixes and definitions remain unchanged. Verify both originals before implementation.

    · Download NTCIP1203v03f.pdf — NTCIP1203-v03-05 (MIB transcription)

Registration

Registration authorities

First Registration Authority (inferred from ancestor 1.3.6.1.4.1.1206)

Schopp Bruce J.

Siblings (30)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.1206.4.2.3.6.1 dmsControlMode00
1.3.6.1.4.1.1206.4.2.3.6.2 dmsSWReset00
1.3.6.1.4.1.1206.4.2.3.6.4 dmsMessageTimeRemaining00
1.3.6.1.4.1.1206.4.2.3.6.5 dmsMsgTableSource00
1.3.6.1.4.1.1206.4.2.3.6.6 dmsMsgRequesterID00
1.3.6.1.4.1.1206.4.2.3.6.7 dmsMsgSourceMode00
1.3.6.1.4.1.1206.4.2.3.6.8 dmsShortPowerRecoveryMessage00
1.3.6.1.4.1.1206.4.2.3.6.9 dmsLongPowerRecoveryMessage00
1.3.6.1.4.1.1206.4.2.3.6.10 dmsShortPowerLossTime00
1.3.6.1.4.1.1206.4.2.3.6.11 dmsResetMessage00
1.3.6.1.4.1.1206.4.2.3.6.12 dmsCommunicationsLossMessage00
1.3.6.1.4.1.1206.4.2.3.6.13 dmsTimeCommLoss00
1.3.6.1.4.1.1206.4.2.3.6.14 dmsPowerLossMessage00
1.3.6.1.4.1.1206.4.2.3.6.15 dmsEndDurationMessage00
1.3.6.1.4.1.1206.4.2.3.6.16 dmsMemoryMgmt00
1.3.6.1.4.1.1206.4.2.3.6.17 dmsActivateMsgError00
1.3.6.1.4.1.1206.4.2.3.6.18 dmsMultiSyntaxError00
1.3.6.1.4.1.1206.4.2.3.6.19 dmsMultiSyntaxErrorPosition00
1.3.6.1.4.1.1206.4.2.3.6.20 dmsMultiOtherErrorDescription00
1.3.6.1.4.1.1206.4.2.3.6.21 vmsPixelServiceDuration00
1.3.6.1.4.1.1206.4.2.3.6.22 vmsPixelServiceFrequency00
1.3.6.1.4.1.1206.4.2.3.6.23 vmsPixelServiceTime00
1.3.6.1.4.1.1206.4.2.3.6.24 dmsActivateErrorMsgCode00
1.3.6.1.4.1.1206.4.2.3.6.25 dmsActivateMessageState00
1.3.6.1.4.1.1206.4.2.3.6.26 dmsActivateMessageV400
1.3.6.1.4.1.1206.4.2.3.6.27 dmsActivateErrorMsgCodeV400
1.3.6.1.4.1.1206.4.2.3.6.28 dmsMsgRequesterAddressType00
1.3.6.1.4.1.1206.4.2.3.6.29 dmsMsgRequesterAddress00
1.3.6.1.4.1.1206.4.2.3.6.30 dmsMsgRequesterSecurityName00
1.3.6.1.4.1.1206.4.2.3.6.31 vmsPixelServiceDurationV400