<Definition> The object identifier of the object instance to be sampled for the recording. The object instance shall be accessed using the security parameters as specified in recMechV2FactorySecurityModel, recMechV2FactorySecurityLevel, recMechV2FactorySecurityName, and recMechV2FactorySampleContext. (See RFC 3415 for details about how the view-based access control model uses these parameters.) An attempt to set this object to a value that is not within the read mib view for the supplied security parameters shall result in a failure of Step 10 of the set operation, thereby resulting in an 'inconsistent value' error. NOTE: The object instance does not have to exist at the time that this object is set for the set to be successful. If the object identifier does not point to a valid object instance within the read mib view for the indicated security parameters at the time that the data is being sampled, the sample shall record a zero- length string. <Object Identifier> 1.3.6.1.4.1.1206.4.2.6.9.2.3.1.6
OID reference
recMechV2FactorySampleOID
1.3.6.1.4.1.1206.4.2.6.9.2.3.1.6
Description
<Definition> The object identifier of the object instance to be sampled for the recording. The object instance shall be accessed using the security parameters as specified in recMechV2FactorySecurityModel, recMechV2FactorySecurityLevel, recMechV2FactorySecurityName, and recMechV2FactorySampleContext. (See RFC 3415 for…
Identification
Identifier and names
- Parent
- 1.3.6.1.4.1.1206.4.2.6.9.2.3.1 (recMechV2FactoryEntry)
- Node code
- 6
- Node name
- recMechV2FactorySampleOID
- Category
- SNMP management object
- Numeric OID
- 1.3.6.1.4.1.1206.4.2.6.9.2.3.1.6
- URN notation
- urn:oid:1.3.6.1.4.1.1206.4.2.6.9.2.3.1.6
ASN.1, OID-IRI and named path variants
- ASN.1 notation
-
{1 3 6 1 4 1 1206 4 2 6 9 2 3 1 6}
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) nema(1206) transportation(4) devices(2) global(6) globalV2(9) recMechV2(2) recMechV2FactoryTable(3) recMechV2FactoryEntry(1) recMechV2FactorySampleOID(6)}
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) nema(1206) transportation(4) devices(2) global(6) globalV2(9) statMultiFieldTable(2) recMechV2FactoryTable(3) recMechV2FactoryEntry(1) recMechV2FactorySampleOID(6)}
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) nema(1206) transportation(4) devices(2) global(6) dmsStatus(9) recMechV2(2) recMechV2FactoryTable(3) recMechV2FactoryEntry(1) recMechV2FactorySampleOID(6)}
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) nema(1206) transportation(4) devices(2) global(6) dmsStatus(9) statMultiFieldTable(2) recMechV2FactoryTable(3) recMechV2FactoryEntry(1) recMechV2FactorySampleOID(6)}
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) nema(1206) transportation(4) devices(2) dms(6) globalV2(9) recMechV2(2) recMechV2FactoryTable(3) recMechV2FactoryEntry(1) recMechV2FactorySampleOID(6)}
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) nema(1206) transportation(4) devices(2) dms(6) globalV2(9) statMultiFieldTable(2) recMechV2FactoryTable(3) recMechV2FactoryEntry(1) recMechV2FactorySampleOID(6)}
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) nema(1206) transportation(4) devices(2) dms(6) dmsStatus(9) recMechV2(2) recMechV2FactoryTable(3) recMechV2FactoryEntry(1) recMechV2FactorySampleOID(6)}
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) nema(1206) transportation(4) devices(2) dms(6) dmsStatus(9) statMultiFieldTable(2) recMechV2FactoryTable(3) recMechV2FactoryEntry(1) recMechV2FactorySampleOID(6)}
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) nema(1206) transportation(4) devices(2) global(6) globalV2(9) recMechV2(2) recMechV2FactoryTable(3) recMechV2FactoryEntry(1) recMechV2FactorySampleOID(6)}
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) nema(1206) transportation(4) devices(2) global(6) globalV2(9) statMultiFieldTable(2) recMechV2FactoryTable(3) recMechV2FactoryEntry(1) recMechV2FactorySampleOID(6)}
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) nema(1206) transportation(4) devices(2) global(6) dmsStatus(9) recMechV2(2) recMechV2FactoryTable(3) recMechV2FactoryEntry(1) recMechV2FactorySampleOID(6)}
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) nema(1206) transportation(4) devices(2) global(6) dmsStatus(9) statMultiFieldTable(2) recMechV2FactoryTable(3) recMechV2FactoryEntry(1) recMechV2FactorySampleOID(6)}
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) nema(1206) transportation(4) devices(2) dms(6) globalV2(9) recMechV2(2) recMechV2FactoryTable(3) recMechV2FactoryEntry(1) recMechV2FactorySampleOID(6)}
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) nema(1206) transportation(4) devices(2) dms(6) globalV2(9) statMultiFieldTable(2) recMechV2FactoryTable(3) recMechV2FactoryEntry(1) recMechV2FactorySampleOID(6)}
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) nema(1206) transportation(4) devices(2) dms(6) dmsStatus(9) recMechV2(2) recMechV2FactoryTable(3) recMechV2FactoryEntry(1) recMechV2FactorySampleOID(6)}
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) nema(1206) transportation(4) devices(2) dms(6) dmsStatus(9) statMultiFieldTable(2) recMechV2FactoryTable(3) recMechV2FactoryEntry(1) recMechV2FactorySampleOID(6)}
- Additional combinations skipped.
- OID-IRI notation
- /1/3/6/1/4/1/1206/4/2/6/9/2/3/1/6
- /ISO/Identified-Organization/6/1/4/1/1206/4/2/6/9/2/3/1/6
- /ISO/3/6/1/4/1/1206/4/2/6/9/2/3/1/6
- Named path variants
- /iso/identified-organization/dod/internet/private/enterprise/1206/transportation/devices/global/globalV2/recMechV2/recMechV2FactoryTable/recMechV2FactoryEntry/recMechV2FactorySampleOID
- /iso/identified-organization/dod/internet/private/enterprise/1206/transportation/devices/global/globalV2/statMultiFieldTable/recMechV2FactoryTable/recMechV2FactoryEntry/recMechV2FactorySampleOID
- /iso/identified-organization/dod/internet/private/enterprise/1206/transportation/devices/global/dmsStatus/recMechV2/recMechV2FactoryTable/recMechV2FactoryEntry/recMechV2FactorySampleOID
- /iso/identified-organization/dod/internet/private/enterprise/1206/transportation/devices/global/dmsStatus/statMultiFieldTable/recMechV2FactoryTable/recMechV2FactoryEntry/recMechV2FactorySampleOID
- /iso/identified-organization/dod/internet/private/enterprise/1206/transportation/devices/dms/globalV2/recMechV2/recMechV2FactoryTable/recMechV2FactoryEntry/recMechV2FactorySampleOID
- /iso/identified-organization/dod/internet/private/enterprise/1206/transportation/devices/dms/globalV2/statMultiFieldTable/recMechV2FactoryTable/recMechV2FactoryEntry/recMechV2FactorySampleOID
- /iso/identified-organization/dod/internet/private/enterprise/1206/transportation/devices/dms/dmsStatus/recMechV2/recMechV2FactoryTable/recMechV2FactoryEntry/recMechV2FactorySampleOID
- /iso/identified-organization/dod/internet/private/enterprise/1206/transportation/devices/dms/dmsStatus/statMultiFieldTable/recMechV2FactoryTable/recMechV2FactoryEntry/recMechV2FactorySampleOID
- /iso/identified-organization/dod/internet/private/enterprise/nema/transportation/devices/global/globalV2/recMechV2/recMechV2FactoryTable/recMechV2FactoryEntry/recMechV2FactorySampleOID
- /iso/identified-organization/dod/internet/private/enterprise/nema/transportation/devices/global/globalV2/statMultiFieldTable/recMechV2FactoryTable/recMechV2FactoryEntry/recMechV2FactorySampleOID
- /iso/identified-organization/dod/internet/private/enterprise/nema/transportation/devices/global/dmsStatus/recMechV2/recMechV2FactoryTable/recMechV2FactoryEntry/recMechV2FactorySampleOID
- /iso/identified-organization/dod/internet/private/enterprise/nema/transportation/devices/global/dmsStatus/statMultiFieldTable/recMechV2FactoryTable/recMechV2FactoryEntry/recMechV2FactorySampleOID
- /iso/identified-organization/dod/internet/private/enterprise/nema/transportation/devices/dms/globalV2/recMechV2/recMechV2FactoryTable/recMechV2FactoryEntry/recMechV2FactorySampleOID
- /iso/identified-organization/dod/internet/private/enterprise/nema/transportation/devices/dms/globalV2/statMultiFieldTable/recMechV2FactoryTable/recMechV2FactoryEntry/recMechV2FactorySampleOID
- /iso/identified-organization/dod/internet/private/enterprise/nema/transportation/devices/dms/dmsStatus/recMechV2/recMechV2FactoryTable/recMechV2FactoryEntry/recMechV2FactorySampleOID
- /iso/identified-organization/dod/internet/private/enterprise/nema/transportation/devices/dms/dmsStatus/statMultiFieldTable/recMechV2FactoryTable/recMechV2FactoryEntry/recMechV2FactorySampleOID
- Additional combinations skipped.
SNMP properties
- Value type
- VariablePointer
- Maximum access defined by MIB
- read-create
- Status in MIB
- current
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
Published definition
The displayed source records contain one distinct definition. Compare its source records.
recMechV2FactorySampleOID OBJECT-TYPE
SYNTAX VariablePointer
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"<Definition> The object identifier of the object instance to be
sampled for the recording. The object instance shall be accessed using
the security parameters as specified in recMechV2FactorySecurityModel,
recMechV2FactorySecurityLevel, recMechV2FactorySecurityName, and
recMechV2FactorySampleContext. (See RFC 3415 for details about how the
view-based access control model uses these parameters.)
An attempt to set this object to a value that is not within the read
mib view for the supplied security parameters shall result in a
failure of Step 10 of the set operation, thereby resulting in an
'inconsistent value' error. NOTE: The object instance does not have to
exist at the time that this object is set for the set to be
successful.
If the object identifier does not point to a valid object instance
within the read mib view for the indicated security parameters at the
time that the data is being sampled, the sample shall record a zero-
length string.
<Object Identifier> 1.3.6.1.4.1.1206.4.2.6.9.2.3.1.6"
::= { recMechV2FactoryEntry 6 }
Meaning
Descriptions
Identical descriptions are grouped. Different wording and device-specific notes are retained.
Evidence
Source records
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Records for description 1ITE public NTCIP working repository MIBs
recMechV2FactorySampleOID · currentITE public NTCIP working repository MIBs
Status in source: current.
Names: recMechV2FactorySampleOID
Technical details
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"recMechV2FactorySampleOID",
"OBJECT-TYPE",
"SYNTAX",
"VariablePointer",
"MAX-ACCESS",
"read-create",
"STATUS",
"current",
"DESCRIPTION",
"\"<Definition> The object identifier of the object instance to be sampled for the recording. The object instance shall be accessed using the security parameters as specified in recMechV2FactorySecurityModel, recMechV2FactorySecurityLevel, recMechV2FactorySecurityName, and recMechV2FactorySampleContext. (See RFC 3415 for details about how the view-based access control model uses these parameters.) An attempt to set this object to a value that is not within the read mib view for the supplied security parameters shall result in a failure of Step 10 of the set operation, thereby resulting in an 'inconsistent value' error. NOTE: The object instance does not have to exist at the time that this object is set for the set to be successful. If the object identifier does not point to a valid object instance within the read mib view for the indicated security parameters at the time that the data is being sampled, the sample shall record a zero- length string. <Object Identifier> 1.3.6.1.4.1.1206.4.2.6.9.2.3.1.6\"",
"::=",
"{",
"recMechV2FactoryEntry",
"6",
"}"
],
"syntax_tree": [
[
"row",
"VariablePointer"
],
null,
[
"MaxAccessPart",
"read-create"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"<Definition> The object identifier of the object instance to be sampled for the recording. The object instance shall be accessed using the security parameters as specified in recMechV2FactorySecurityModel, recMechV2FactorySecurityLevel, recMechV2FactorySecurityName, and recMechV2FactorySampleContext. (See RFC 3415 for details about how the view-based access control model uses these parameters.) An attempt to set this object to a value that is not within the read mib view for the supplied security parameters shall result in a failure of Step 10 of the set operation, thereby resulting in an 'inconsistent value' error. NOTE: The object instance does not have to exist at the time that this object is set for the set to be successful. If the object identifier does not point to a valid object instance within the read mib view for the indicated security parameters at the time that the data is being sampled, the sample shall record a zero- length string. <Object Identifier> 1.3.6.1.4.1.1206.4.2.6.9.2.3.1.6"
],
null,
null,
null,
null
]
}- ITE public NTCIP working repository MIBs
· Publisher's source file: NTCIP-1201 — ntcip1201-AuxIO.mib
Module: NTCIP1201-RecMechV2
See published definition above
Module imports
{'SNMPv2-TC': ['RowPointer', 'RowStatus', 'StorageType', 'TruthValue', 'VariablePointer'], 'SNMPv2-SMI': ['zeroDotZero', 'MODULE-IDENTITY', 'OBJECT-TYPE', 'OBJECT-IDENTITY', 'Unsigned32'], 'SNMPv2-CONF': ['OBJECT-GROUP'], 'ISO20684-1-TC': ['ITSCounter16', 'ITSCounter32', 'ITSClear', 'ITSDateStamp', 'ITSDailyTimeStamp', 'ITSOerString', 'ITSPercent', 'ITSPositive8', 'ITSUnsigned8', 'ITSPositive16', 'ITSUnsigned16'], 'ISO20684-7-Owner': ['fdOwnerEntry', 'fdOwnerID'], 'NTCIP1201-Global': ['globalV2', 'adminGlobalV2'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString', 'SnmpSecurityModel', 'SnmpSecurityLevel']}Source data warning: This original is published in an ITE NTCIP working repository. Repository publication does not establish that this particular revision is an adopted standard. Consult its native revision history and the NTCIP published standards catalog before implementation. Copyright and distribution notices are retained in the downloadable original.
· Download NTCIP-1201 — ntcip1201-AuxIO.mibSame file in ntcip1201-SNMPConfig.mib.
Same file in ntcip1201-Security.mib.
Same file in ntcip1201-ProfilesSTMP.mib.
Same file in ntcip1201-NtcipTraps.mib.
Registration
Registration authorities
First Registration Authority (inferred from ancestor 1.3.6.1.4.1.1206)
Siblings (12)
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.1206.4.2.6.9.2.3.1.1 | recMechV2FactoryID | 0 | 0 | |
| 1.3.6.1.4.1.1206.4.2.6.9.2.3.1.2 | recMechV2FactorySecurityModel | 0 | 0 | |
| 1.3.6.1.4.1.1206.4.2.6.9.2.3.1.3 | recMechV2FactorySecurityLevel | 0 | 0 | |
| 1.3.6.1.4.1.1206.4.2.6.9.2.3.1.4 | recMechV2FactorySecurityName | 0 | 0 | |
| 1.3.6.1.4.1.1206.4.2.6.9.2.3.1.5 | recMechV2FactorySampleContext | 0 | 0 | |
| 1.3.6.1.4.1.1206.4.2.6.9.2.3.1.7 | recMechV2FactoryPreSamples | 0 | 0 | |
| 1.3.6.1.4.1.1206.4.2.6.9.2.3.1.8 | recMechV2FactorySamplePeriod | 0 | 0 | |
| 1.3.6.1.4.1.1206.4.2.6.9.2.3.1.9 | recMechV2FactoryMonitorContext | 0 | 0 | |
| 1.3.6.1.4.1.1206.4.2.6.9.2.3.1.10 | recMechV2FactoryMonitorOID | 0 | 0 | |
| 1.3.6.1.4.1.1206.4.2.6.9.2.3.1.11 | recMechV2FactorySampleLimit | 0 | 0 | |
| 1.3.6.1.4.1.1206.4.2.6.9.2.3.1.12 | recMechV2FactoryStorageType | 0 | 0 | |
| 1.3.6.1.4.1.1206.4.2.6.9.2.3.1.13 | recMechV2FactoryRowStatus | 0 | 0 |