Operation mode of the device (Inline or Offlinet or Transparent or WCCP)
Sources for this description
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)Netdisco MIB archive copies
OID reference
1.3.6.1.4.1.12356.107.2.1.4
Operation mode of the device (Inline or Offlinet or Transparent or WCCP)
Identification
{1 3 6 1 4 1 12356 107 2 1 4}
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
The displayed source records contain one distinct definition. Compare its source records.
fwSysOpMode OBJECT-TYPE
SYNTAX FwOpMode
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Operation mode of the device (Inline or Offlinet or Transparent or WCCP)"
::= { fwSystemInfo 4 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
Operation mode of the device (Inline or Offlinet or Transparent or WCCP)
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)Netdisco MIB archive copies
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: current.
Names: fwSysOpMode
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"fwSysOpMode",
"OBJECT-TYPE",
"SYNTAX",
"FwOpMode",
"MAX-ACCESS",
"read-only",
"STATUS",
"current",
"DESCRIPTION",
"\"Operation mode of the device (Inline or Offlinet or Transparent or WCCP)\"",
"::=",
"{",
"fwSystemInfo",
"4",
"}"
],
"syntax_tree": [
[
"row",
"FwOpMode"
],
null,
[
"MaxAccessPart",
"read-only"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"Operation mode of the device (Inline or Offlinet or Transparent or WCCP)"
],
null,
null,
null,
null
]
}Vendor MIB copy from the LibreNMS archive.
Module: FORTINET-FORTIWEB-MIB
See published definition above
{'SNMPv2-TC': ['DisplayString', 'TEXTUAL-CONVENTION'], 'SNMPv2-MIB': ['sysName'], 'SNMPv2-SMI': ['Counter32', 'Gauge32', 'Integer32', 'MODULE-IDENTITY', 'NOTIFICATION-TYPE', 'OBJECT-TYPE'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'NOTIFICATION-GROUP', 'OBJECT-GROUP'], 'FORTINET-CORE-MIB': ['fnSysSerial', 'fortinet']}Related source files and packages:
Same file in Observium Community.
Vendor MIB copy from the Netdisco archive.
Module: FORTINET-FORTIWEB-MIB
{'SNMPv2-TC': ['DisplayString', 'TEXTUAL-CONVENTION'], 'SNMPv2-MIB': ['sysName'], 'SNMPv2-SMI': ['Counter32', 'Gauge32', 'Integer32', 'MODULE-IDENTITY', 'NOTIFICATION-TYPE', 'OBJECT-TYPE'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'NOTIFICATION-GROUP', 'OBJECT-GROUP'], 'FORTINET-CORE-MIB': ['fnSysSerial', 'fortinet']}Related source files and packages:
Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.12356.107.2.1.1 | fwSysModel | 0 | 0 | |
| 1.3.6.1.4.1.12356.107.2.1.2 | fwSysVersion | 0 | 0 | |
| 1.3.6.1.4.1.12356.107.2.1.3 | fwSysHaMode | 0 | 0 | |
| 1.3.6.1.4.1.12356.107.2.1.5 | fwSysCpuUsage | 0 | 0 | |
| 1.3.6.1.4.1.12356.107.2.1.6 | fwSysCpuFreq | 0 | 0 | |
| 1.3.6.1.4.1.12356.107.2.1.7 | fwSysMemUsage | 0 | 0 | |
| 1.3.6.1.4.1.12356.107.2.1.8 | fwSysMemCapacity | 0 | 0 | |
| 1.3.6.1.4.1.12356.107.2.1.9 | fwSysDiskUsage | 0 | 0 | |
| 1.3.6.1.4.1.12356.107.2.1.10 | fwSysDiskCapacity | 0 | 0 |