Sent when a slot other than the primary CTX experiences a timing state change. Only applicable in SAOS 8.x.
Sources for this description
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
OID reference
1.3.6.1.4.1.1271.2.2.28.0.3
Sent when a slot other than the primary CTX experiences a timing state change. Only applicable in SAOS 8.x.
Identification
{1 3 6 1 4 1 1271 2 2 28 0 3}
The displayed source records contain one distinct definition. Compare its source records.
cienaCesSyncModuleSlotClockStateChangeNotification NOTIFICATION-TYPE
OBJECTS {
cienaGlobalSeverity,
cienaGlobalMacAddress,
cienaCesModuleSlotName,
cienaCesSyncModuleSlotClockStatus
}
STATUS current
DESCRIPTION
"Sent when a slot other than the primary CTX experiences a timing state change. Only applicable in SAOS 8.x."
::= { cienaCesTimeSyncMIBNotifications 3 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
Sent when a slot other than the primary CTX experiences a timing state change. Only applicable in SAOS 8.x.
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: current.
Names: cienaCesSyncModuleSlotClockStateChangeNotification
{
"smi_kind": "NOTIFICATION-TYPE",
"definition": [
"cienaCesSyncModuleSlotClockStateChangeNotification",
"NOTIFICATION-TYPE",
"OBJECTS",
"{",
"cienaGlobalSeverity",
",",
"cienaGlobalMacAddress",
",",
"cienaCesModuleSlotName",
",",
"cienaCesSyncModuleSlotClockStatus",
"}",
"STATUS",
"current",
"DESCRIPTION",
"\"Sent when a slot other than the primary CTX experiences a timing state change. Only applicable in SAOS 8.x.\"",
"::=",
"{",
"cienaCesTimeSyncMIBNotifications",
"3",
"}"
],
"syntax_tree": [
[
"Objects",
[
"cienaGlobalSeverity",
"cienaGlobalMacAddress",
"cienaCesModuleSlotName",
"cienaCesSyncModuleSlotClockStatus"
]
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"Sent when a slot other than the primary CTX experiences a timing state change. Only applicable in SAOS 8.x."
],
null
]
}Vendor MIB copy from the LibreNMS archive.
Module: CIENA-CES-TIME-SYNC-MIB
See published definition above
{'CIENA-TC': ['CienaGlobalState'], 'CIENA-SMI': ['cienaCesConfig', 'cienaCesNotifications'], 'SNMPv2-TC': ['DisplayString', 'TEXTUAL-CONVENTION'], 'SNMPv2-SMI': ['Integer32', 'Unsigned32', 'OBJECT-TYPE', 'MODULE-IDENTITY', 'NOTIFICATION-TYPE'], 'CIENA-GLOBAL-MIB': ['cienaGlobalSeverity', 'cienaGlobalMacAddress'], 'CIENA-CES-MODULE-MIB': ['cienaCesModuleSlotName']}Related source files and packages:
Same file in Observium Community.
Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.1271.2.2.28.0.1 | cienaCesSyncInputPUStateChangeNotification | 0 | 0 | |
| 1.3.6.1.4.1.1271.2.2.28.0.2 | cienaCesSyncInputProtectionGroupStateChangeNotification | 0 | 0 |