Status in source: current.
Names: cienaCesPmAlertTcaConfigStatus
Technical details
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"cienaCesPmAlertTcaConfigStatus",
"OBJECT-TYPE",
"SYNTAX",
"PmTcaConfigStatus",
"MAX-ACCESS",
"read-only",
"STATUS",
"current",
"DESCRIPTION",
"\"This object indicates whether the Alert TCA configuration attributes are configured in a way for periodic Alert TCA state monitoring and reporting to occur on behalf of the PM Instance. This status refers to the Alert TCA functionality comprising of the following necessary configuration attributes: 1. cienaCesPmIntervalProfileAlertInterval 2. cienaCesPmIntervalProfileAlertThresholdPercentage noProfile indicates there is no interval profile configured for the PM Instance. notConfigured indicates the PM instance is configured with a particular interval profile, however none of the necessary configuration attributes for the Alert TCA feature are configured. partiallyConfigured indicates the PM instance is configured with a particular interval profile and that some, but not all, of the necessary configuration attributes for the Alert TCA feature are configured. configured indicates the PM instance is configured with a particular interval profile and that all of the necessary configuration attributes for the Alert TCA feature are configured.\"",
"::=",
"{",
"cienaCesPmInstanceAlertTcaEntry",
"4",
"}"
],
"syntax_tree": [
[
"row",
"PmTcaConfigStatus"
],
null,
[
"MaxAccessPart",
"read-only"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"This object indicates whether the Alert TCA configuration attributes are configured in a way for periodic Alert TCA state monitoring and reporting to occur on behalf of the PM Instance. This status refers to the Alert TCA functionality comprising of the following necessary configuration attributes: 1. cienaCesPmIntervalProfileAlertInterval 2. cienaCesPmIntervalProfileAlertThresholdPercentage noProfile indicates there is no interval profile configured for the PM Instance. notConfigured indicates the PM instance is configured with a particular interval profile, however none of the necessary configuration attributes for the Alert TCA feature are configured. partiallyConfigured indicates the PM instance is configured with a particular interval profile and that some, but not all, of the necessary configuration attributes for the Alert TCA feature are configured. configured indicates the PM instance is configured with a particular interval profile and that all of the necessary configuration attributes for the Alert TCA feature are configured."
],
null,
null,
null,
null
]
}
- Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
· Publisher's source file: CIENA-CES-PM
Vendor MIB copy from the LibreNMS archive.
Module: CIENA-CES-PM
See published definition above
Module imports
{'CIENA-TC': ['CienaGlobalState', 'CienaStatsClear'], 'CIENA-SMI': ['cienaCesStatistics', 'cienaCesNotifications'], 'SNMPv2-TC': ['DisplayString', 'RowStatus', 'TruthValue', 'TEXTUAL-CONVENTION'], 'SNMPv2-SMI': ['Integer32', 'Counter64', 'Unsigned32', 'NOTIFICATION-TYPE', 'OBJECT-TYPE', 'MODULE-IDENTITY'], 'CIENA-GLOBAL-MIB': ['cienaGlobalSeverity', 'cienaGlobalMacAddress']}
· Download CIENA-CES-PM
Related source files and packages:
- Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
· Publisher's source file: Source package: observium-community-latest.tar.gz
Vendor MIB copy from the Observium Community archive.
Module: CIENA-CES-PM
Same published definition
Module imports
{'CIENA-TC': ['CienaGlobalState', 'CienaStatsClear'], 'CIENA-SMI': ['cienaCesStatistics', 'cienaCesNotifications'], 'SNMPv2-TC': ['DisplayString', 'RowStatus', 'TruthValue', 'TEXTUAL-CONVENTION'], 'SNMPv2-SMI': ['Integer32', 'Counter64', 'Unsigned32', 'NOTIFICATION-TYPE', 'OBJECT-TYPE', 'MODULE-IDENTITY'], 'CIENA-GLOBAL-MIB': ['cienaGlobalSeverity', 'cienaGlobalMacAddress']}
· Download CIENA-CES-PM