Ciena OME6500 Active Alarm Table Extension Probable Cause
Sources for this description
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
OID reference
1.3.6.1.4.1.1271.29.6.1.1.1.2
Ciena OME6500 Active Alarm Table Extension Probable Cause
Identification
{1 3 6 1 4 1 1271 29 6 1 1 1 2}
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
The displayed source records contain one distinct definition. Compare its source records.
ome6500ExtAlarmActiveProbableCause OBJECT-TYPE
SYNTAX Ome6500ExtAlarmProbableCause
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Ciena OME6500 Active Alarm Table Extension Probable Cause"
::= { ome6500ExtAlarmActiveEntry 2 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
Ciena OME6500 Active Alarm Table Extension Probable Cause
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
Evidence
Matching descriptions are grouped; representative source files are shown for each definition.
Status in source: current.
Names: ome6500ExtAlarmActiveProbableCause
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"ome6500ExtAlarmActiveProbableCause",
"OBJECT-TYPE",
"SYNTAX",
"Ome6500ExtAlarmProbableCause",
"MAX-ACCESS",
"read-write",
"STATUS",
"current",
"DESCRIPTION",
"\"Ciena OME6500 Active Alarm Table Extension Probable Cause\"",
"::=",
"{",
"ome6500ExtAlarmActiveEntry",
"2",
"}"
],
"syntax_tree": [
[
"row",
"Ome6500ExtAlarmProbableCause"
],
null,
[
"MaxAccessPart",
"read-write"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"Ciena OME6500 Active Alarm Table Extension Probable Cause"
],
null,
null,
null,
null
]
}Vendor MIB copy from the Observium Community archive.
Module: CIENA-OME6500-ALARM-EXT-MIB
See published definition above
{'CIENA-SMI': ['cienaGenericMIBs'], 'SNMPv2-TC': ['TEXTUAL-CONVENTION', 'DateAndTime'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'Integer32'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString'], 'NOTIFICATION-LOG-MIB': ['nlmLogName', 'nlmLogIndex']}Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.1271.29.6.1.1.1.1 | ome6500ExtAlarmActiveEventType | 0 | 0 | |
| 1.3.6.1.4.1.1271.29.6.1.1.1.3 | ome6500ExtAlarmActiveAdditionalText | 0 | 0 | |
| 1.3.6.1.4.1.1271.29.6.1.1.1.4 | ome6500ExtAlarmActiveDocumentationPointer | 0 | 0 | |
| 1.3.6.1.4.1.1271.29.6.1.1.1.5 | ome6500ExtAlarmActiveResourceDescription | 0 | 0 | |
| 1.3.6.1.4.1.1271.29.6.1.1.1.6 | ome6500ExtAlarmActiveManualClear | 0 | 0 | |
| 1.3.6.1.4.1.1271.29.6.1.1.1.7 | ome6500ExtAlarmActiveSequenceNumber | 0 | 0 |