The power meter type: 3-phase, single-phase or split-phase.
Sources for this description
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
OID reference
1.3.6.1.4.1.13742.6.3.10.2.1.9
The power meter type: 3-phase, single-phase or split-phase.
Identification
{1 3 6 1 4 1 13742 6 3 10 2 1 9}
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
The displayed source records contain one distinct definition. Compare its source records.
powerMeterType OBJECT-TYPE
SYNTAX PowerMeterTypeEnumeration
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The power meter type: 3-phase, single-phase or split-phase."
::= { powerMeterConfigurationEntry 9 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
The power meter type: 3-phase, single-phase or split-phase.
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: current.
Names: powerMeterType
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"powerMeterType",
"OBJECT-TYPE",
"SYNTAX",
"PowerMeterTypeEnumeration",
"MAX-ACCESS",
"read-only",
"STATUS",
"current",
"DESCRIPTION",
"\"The power meter type: 3-phase, single-phase or split-phase.\"",
"::=",
"{",
"powerMeterConfigurationEntry",
"9",
"}"
],
"syntax_tree": [
[
"row",
"PowerMeterTypeEnumeration"
],
null,
[
"MaxAccessPart",
"read-only"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"The power meter type: 3-phase, single-phase or split-phase."
],
null,
null,
null,
null
]
}Vendor MIB copy from the LibreNMS archive.
Module: PDU2-MIB
See published definition above
{'SNMPv2-TC': ['TEXTUAL-CONVENTION', 'DisplayString', 'MacAddress', 'TruthValue', 'RowPointer'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'enterprises', 'Integer32', 'Unsigned32', 'IpAddress'], 'RFC1213-MIB': ['sysContact', 'sysName', 'sysLocation'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP', 'NOTIFICATION-GROUP'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress', 'InetPortNumber']}Related source files and packages:
Vendor MIB copy from the Observium Community archive.
Module: PDU2-MIB
{'SNMPv2-TC': ['TEXTUAL-CONVENTION', 'DisplayString', 'MacAddress', 'TruthValue', 'RowPointer'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'enterprises', 'Integer32', 'Unsigned32', 'IpAddress'], 'RFC1213-MIB': ['sysContact', 'sysName', 'sysLocation'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP', 'NOTIFICATION-GROUP'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress', 'InetPortNumber']}Related source files and packages:
Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.13742.6.3.10.2.1.2 | powerMeterPhaseCTRating | 0 | 0 | |
| 1.3.6.1.4.1.13742.6.3.10.2.1.3 | powerMeterNeutralCTRating | 0 | 0 | |
| 1.3.6.1.4.1.13742.6.3.10.2.1.4 | powerMeterEarthCTRating | 0 | 0 | |
| 1.3.6.1.4.1.13742.6.3.10.2.1.5 | powerMeterBranchCount | 0 | 0 | |
| 1.3.6.1.4.1.13742.6.3.10.2.1.6 | powerMeterPanelPositions | 0 | 0 | |
| 1.3.6.1.4.1.13742.6.3.10.2.1.7 | powerMeterPanelLayout | 0 | 0 | |
| 1.3.6.1.4.1.13742.6.3.10.2.1.8 | powerMeterPanelNumbering | 0 | 0 |