inletPoleCount

1.3.6.1.4.1.13742.6.3.3.3.1.5

Description

The number of poles. PDU: 2 for 1-phase circuits 3 for 3-phase delta-wired models 4 for 3-phase wye-wired models, pole 4 is neutral Power Meter: 2 to 5 depending on the power meter type: Pole 1 is Phase A Pole 2 is Phase B Pole 3 is Phase C Pole 4 is Neutral Pole 5 is Earth

Full description and source information

Identification

Identifier and names

Parent
1.3.6.1.4.1.13742.6.3.3.3.1 (inletConfigurationEntry)
Node code
5
Node name
inletPoleCount
Category
SNMP management object
Numeric OID
1.3.6.1.4.1.13742.6.3.3.3.1.5
URN notation
urn:oid:1.3.6.1.4.1.13742.6.3.3.3.1.5
ASN.1, OID-IRI and named path variants
ASN.1 notation

{1 3 6 1 4 1 13742 6 3 3 3 1 5}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) aphel(13742) pdu2(6) configuration(3) inlets(3) inletConfigurationTable(3) inletConfigurationEntry(1) inletPoleCount(5)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) raritan(13742) pdu2(6) configuration(3) inlets(3) inletConfigurationTable(3) inletConfigurationEntry(1) inletPoleCount(5)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) aphel(13742) pdu2(6) configuration(3) inlets(3) inletConfigurationTable(3) inletConfigurationEntry(1) inletPoleCount(5)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) raritan(13742) pdu2(6) configuration(3) inlets(3) inletConfigurationTable(3) inletConfigurationEntry(1) inletPoleCount(5)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) aphel(13742) pdu2(6) configuration(3) inlets(3) inletConfigurationTable(3) inletConfigurationEntry(1) inletPoleCount(5)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) raritan(13742) pdu2(6) configuration(3) inlets(3) inletConfigurationTable(3) inletConfigurationEntry(1) inletPoleCount(5)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) aphel(13742) pdu2(6) configuration(3) inlets(3) inletConfigurationTable(3) inletConfigurationEntry(1) inletPoleCount(5)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) raritan(13742) pdu2(6) configuration(3) inlets(3) inletConfigurationTable(3) inletConfigurationEntry(1) inletPoleCount(5)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) aphel(13742) pdu2(6) configuration(3) inlets(3) inletConfigurationTable(3) inletConfigurationEntry(1) inletPoleCount(5)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) raritan(13742) pdu2(6) configuration(3) inlets(3) inletConfigurationTable(3) inletConfigurationEntry(1) inletPoleCount(5)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) aphel(13742) pdu2(6) configuration(3) inlets(3) inletConfigurationTable(3) inletConfigurationEntry(1) inletPoleCount(5)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) raritan(13742) pdu2(6) configuration(3) inlets(3) inletConfigurationTable(3) inletConfigurationEntry(1) inletPoleCount(5)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) aphel(13742) pdu2(6) configuration(3) inlets(3) inletConfigurationTable(3) inletConfigurationEntry(1) inletPoleCount(5)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) raritan(13742) pdu2(6) configuration(3) inlets(3) inletConfigurationTable(3) inletConfigurationEntry(1) inletPoleCount(5)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) aphel(13742) pdu2(6) configuration(3) inlets(3) inletConfigurationTable(3) inletConfigurationEntry(1) inletPoleCount(5)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) raritan(13742) pdu2(6) configuration(3) inlets(3) inletConfigurationTable(3) inletConfigurationEntry(1) inletPoleCount(5)}
  • Additional combinations skipped.
OID-IRI notation
  • /1/3/6/1/4/1/13742/6/3/3/3/1/5
  • /ISO/Identified-Organization/6/1/4/1/13742/6/3/3/3/1/5
  • /ISO/3/6/1/4/1/13742/6/3/3/3/1/5
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/aphel/pdu2/configuration/inlets/inletConfigurationTable/inletConfigurationEntry/inletPoleCount
  • /iso/identified-organization/dod/internet/private/enterprise/raritan/pdu2/configuration/inlets/inletConfigurationTable/inletConfigurationEntry/inletPoleCount
  • /iso/identified-organization/dod/internet/private/enterprises/aphel/pdu2/configuration/inlets/inletConfigurationTable/inletConfigurationEntry/inletPoleCount
  • /iso/identified-organization/dod/internet/private/enterprises/raritan/pdu2/configuration/inlets/inletConfigurationTable/inletConfigurationEntry/inletPoleCount
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/aphel/pdu2/configuration/inlets/inletConfigurationTable/inletConfigurationEntry/inletPoleCount
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/raritan/pdu2/configuration/inlets/inletConfigurationTable/inletConfigurationEntry/inletPoleCount
  • /iso/identified-organization/dod/internet/private/vendor-objects/aphel/pdu2/configuration/inlets/inletConfigurationTable/inletConfigurationEntry/inletPoleCount
  • /iso/identified-organization/dod/internet/private/vendor-objects/raritan/pdu2/configuration/inlets/inletConfigurationTable/inletConfigurationEntry/inletPoleCount
  • /iso/org/dod/internet/private/enterprise/aphel/pdu2/configuration/inlets/inletConfigurationTable/inletConfigurationEntry/inletPoleCount
  • /iso/org/dod/internet/private/enterprise/raritan/pdu2/configuration/inlets/inletConfigurationTable/inletConfigurationEntry/inletPoleCount
  • /iso/org/dod/internet/private/enterprises/aphel/pdu2/configuration/inlets/inletConfigurationTable/inletConfigurationEntry/inletPoleCount
  • /iso/org/dod/internet/private/enterprises/raritan/pdu2/configuration/inlets/inletConfigurationTable/inletConfigurationEntry/inletPoleCount
  • /iso/org/dod/internet/private/ldap-enterprise/aphel/pdu2/configuration/inlets/inletConfigurationTable/inletConfigurationEntry/inletPoleCount
  • /iso/org/dod/internet/private/ldap-enterprise/raritan/pdu2/configuration/inlets/inletConfigurationTable/inletConfigurationEntry/inletPoleCount
  • /iso/org/dod/internet/private/vendor-objects/aphel/pdu2/configuration/inlets/inletConfigurationTable/inletConfigurationEntry/inletPoleCount
  • /iso/org/dod/internet/private/vendor-objects/raritan/pdu2/configuration/inlets/inletConfigurationTable/inletConfigurationEntry/inletPoleCount
  • Additional combinations skipped.

SNMP properties

Value type
Integer32
Maximum access defined by MIB
read-only
Status in MIB
current
Allowed ranges
2–5

Using this OID with SNMP

At least one MIB declaration places this object in a table row. A value belongs to a row instance; its suffix depends on the row's INDEX or AUGMENTS definition.

In PDU2-MIB, the row index consists of these components in order:

  1. pduId (Integer32): one numeric subidentifier for the non-negative value.
  2. inletId (Integer32): one numeric subidentifier for the non-negative value.

An instance has the form .1.3.6.1.4.1.13742.6.3.3.3.1.5.<pduId>.<inletId>. Use values present on the device and permitted by its MIB. Other definitions can differ.

snmpwalk [connection options] DEVICE .1.3.6.1.4.1.13742.6.3.3.3.1.5

Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.

Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.

The displayed source records contain one distinct definition. Compare its source records.

inletPoleCount OBJECT-TYPE
    SYNTAX     Integer32(2..5)
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
           "The number of poles.
            PDU:
              2 for 1-phase circuits
              3 for 3-phase delta-wired models
              4 for 3-phase wye-wired models, pole 4 is neutral
            Power Meter:
              2 to 5 depending on the power meter type:
                Pole 1 is Phase A
                Pole 2 is Phase B
                Pole 3 is Phase C
                Pole 4 is Neutral
                Pole 5 is Earth"
    ::= { inletConfigurationEntry 5 }

Meaning

Descriptions

1 unique

Identical descriptions are grouped. Different wording and device-specific notes are retained.

The number of poles. PDU: 2 for 1-phase circuits 3 for 3-phase delta-wired models 4 for 3-phase wye-wired models, pole 4 is neutral Power Meter: 2 to 5 depending on the power meter type: Pole 1 is Phase A Pole 2 is Phase B Pole 3 is Phase C Pole 4 is Neutral Pole 5 is Earth

Sources for this description

Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

See 1 matching source record

Evidence

Source records

1 records

Matching descriptions are grouped; open a group to compare definitions and supporting files.

Records for description 1Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 record · 2 sources

Description 1

inletPoleCount · currentMultiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)2 sources

Status in source: current.

Names: inletPoleCount

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "inletPoleCount",
    "OBJECT-TYPE",
    "SYNTAX",
    "Integer32",
    "(",
    "2",
    ".",
    ".",
    "5",
    ")",
    "MAX-ACCESS",
    "read-only",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"The number of poles. PDU: 2 for 1-phase circuits 3 for 3-phase delta-wired models 4 for 3-phase wye-wired models, pole 4 is neutral Power Meter: 2 to 5 depending on the power meter type: Pole 1 is Phase A Pole 2 is Phase B Pole 3 is Phase C Pole 4 is Neutral Pole 5 is Earth\"",
    "::=",
    "{",
    "inletConfigurationEntry",
    "5",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "Integer32",
      [
        "integerSubType",
        [
          [
            2,
            5
          ]
        ]
      ]
    ],
    null,
    [
      "MaxAccessPart",
      "read-only"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "The number of poles. PDU: 2 for 1-phase circuits 3 for 3-phase delta-wired models 4 for 3-phase wye-wired models, pole 4 is neutral Power Meter: 2 to 5 depending on the power meter type: Pole 1 is Phase A Pole 2 is Phase B Pole 3 is Phase C Pole 4 is Neutral Pole 5 is Earth"
    ],
    null,
    null,
    null,
    null
  ]
}

Registration

Registration authorities

First Registration Authority (inferred from ancestor 1.3.6.1.4.1.13742)

Yang Allen

Siblings (16)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.13742.6.3.3.3.1.1 inletId00
1.3.6.1.4.1.13742.6.3.3.3.1.2 inletLabel00
1.3.6.1.4.1.13742.6.3.3.3.1.3 inletName00
1.3.6.1.4.1.13742.6.3.3.3.1.4 inletPlug00
1.3.6.1.4.1.13742.6.3.3.3.1.6 inletRatedVoltage00
1.3.6.1.4.1.13742.6.3.3.3.1.7 inletRatedCurrent00
1.3.6.1.4.1.13742.6.3.3.3.1.8 inletRatedFrequency00
1.3.6.1.4.1.13742.6.3.3.3.1.9 inletRatedVA00
1.3.6.1.4.1.13742.6.3.3.3.1.10 inletDeviceCapabilities00
1.3.6.1.4.1.13742.6.3.3.3.1.11 inletPoleCapabilities00
1.3.6.1.4.1.13742.6.3.3.3.1.12 inletPlugDescriptor00
1.3.6.1.4.1.13742.6.3.3.3.1.13 inletEnableState00
1.3.6.1.4.1.13742.6.3.3.3.1.14 inletRCMResidualOperatingCurrent00
1.3.6.1.4.1.13742.6.3.3.3.1.15 inletIsDC00
1.3.6.1.4.1.13742.6.3.3.3.1.16 inletLinePairCount00
1.3.6.1.4.1.13742.6.3.3.3.1.17 inletLinePairCapabilities00