The outlet state when powering the respective inlet. This value is ignored if relayBehaviorOnPowerLoss is set to latching.
Sources for this description
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
OID reference
1.3.6.1.4.1.13742.6.3.5.3.1.13
The outlet state when powering the respective inlet. This value is ignored if relayBehaviorOnPowerLoss is set to latching.
Identification
{1 3 6 1 4 1 13742 6 3 5 3 1 13}
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
The displayed source records contain one distinct definition. Compare its source records.
outletStateOnStartup OBJECT-TYPE
SYNTAX OutletStateOnStartupEnumeration
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The outlet state when powering the respective inlet.
This value is ignored if relayBehaviorOnPowerLoss is set to latching."
::= { outletConfigurationEntry 13 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
The outlet state when powering the respective inlet. This value is ignored if relayBehaviorOnPowerLoss is set to latching.
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: current.
Names: outletStateOnStartup
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"outletStateOnStartup",
"OBJECT-TYPE",
"SYNTAX",
"OutletStateOnStartupEnumeration",
"MAX-ACCESS",
"read-write",
"STATUS",
"current",
"DESCRIPTION",
"\"The outlet state when powering the respective inlet. This value is ignored if relayBehaviorOnPowerLoss is set to latching.\"",
"::=",
"{",
"outletConfigurationEntry",
"13",
"}"
],
"syntax_tree": [
[
"row",
"OutletStateOnStartupEnumeration"
],
null,
[
"MaxAccessPart",
"read-write"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"The outlet state when powering the respective inlet. This value is ignored if relayBehaviorOnPowerLoss is set to latching."
],
null,
null,
null,
null
]
}Vendor MIB copy from the LibreNMS archive.
Module: PDU2-MIB
See published definition above
{'SNMPv2-TC': ['TEXTUAL-CONVENTION', 'DisplayString', 'MacAddress', 'TruthValue', 'RowPointer'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'enterprises', 'Integer32', 'Unsigned32', 'IpAddress'], 'RFC1213-MIB': ['sysContact', 'sysName', 'sysLocation'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP', 'NOTIFICATION-GROUP'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress', 'InetPortNumber']}Related source files and packages:
Vendor MIB copy from the Observium Community archive.
Module: PDU2-MIB
{'SNMPv2-TC': ['TEXTUAL-CONVENTION', 'DisplayString', 'MacAddress', 'TruthValue', 'RowPointer'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'enterprises', 'Integer32', 'Unsigned32', 'IpAddress'], 'RFC1213-MIB': ['sysContact', 'sysName', 'sysLocation'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP', 'NOTIFICATION-GROUP'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress', 'InetPortNumber']}Related source files and packages:
Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.13742.6.3.5.3.1.1 | outletId | 0 | 0 | |
| 1.3.6.1.4.1.13742.6.3.5.3.1.2 | outletLabel | 0 | 0 | |
| 1.3.6.1.4.1.13742.6.3.5.3.1.3 | outletName | 0 | 0 | |
| 1.3.6.1.4.1.13742.6.3.5.3.1.4 | outletReceptacle | 0 | 0 | |
| 1.3.6.1.4.1.13742.6.3.5.3.1.5 | outletPoleCount | 0 | 0 | |
| 1.3.6.1.4.1.13742.6.3.5.3.1.6 | outletRatedVoltage | 0 | 0 | |
| 1.3.6.1.4.1.13742.6.3.5.3.1.7 | outletRatedCurrent | 0 | 0 | |
| 1.3.6.1.4.1.13742.6.3.5.3.1.8 | outletRatedVA | 0 | 0 | |
| 1.3.6.1.4.1.13742.6.3.5.3.1.10 | outletDeviceCapabilities | 0 | 0 | |
| 1.3.6.1.4.1.13742.6.3.5.3.1.11 | outletPoleCapabilities | 0 | 0 | |
| 1.3.6.1.4.1.13742.6.3.5.3.1.12 | outletPowerCyclingPowerOffPeriod | 0 | 0 | |
| 1.3.6.1.4.1.13742.6.3.5.3.1.14 | outletUseGlobalPowerCyclingPowerOffPeriod | 0 | 0 | |
| 1.3.6.1.4.1.13742.6.3.5.3.1.28 | outletSwitchable | 0 | 0 | |
| 1.3.6.1.4.1.13742.6.3.5.3.1.29 | outletReceptacleDescriptor | 0 | 0 | |
| 1.3.6.1.4.1.13742.6.3.5.3.1.30 | outletNonCritical | 0 | 0 | |
| 1.3.6.1.4.1.13742.6.3.5.3.1.32 | outletSequenceDelay | 0 | 0 | |
| 1.3.6.1.4.1.13742.6.3.5.3.1.33 | outletPowerSource | 0 | 0 | |
| 1.3.6.1.4.1.13742.6.3.5.3.1.34 | outletServiceMode | 0 | 0 |