An entry containing inlet sensor measurement objects.
Sources for this description
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
OID reference
1.3.6.1.4.1.13742.6.5.2.3.1
An entry containing inlet sensor measurement objects.
Identification
{1 3 6 1 4 1 13742 6 5 2 3 1}
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
The displayed source records contain one distinct definition. Compare its source records.
inletSensorMeasurementsEntry OBJECT-TYPE
SYNTAX InletSensorMeasurementsEntryStruct
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry containing inlet sensor measurement objects."
INDEX { pduId, inletId, sensorType }
::= { inletSensorMeasurementsTable 1 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
An entry containing inlet sensor measurement objects.
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: current.
Names: inletSensorMeasurementsEntry
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"inletSensorMeasurementsEntry",
"OBJECT-TYPE",
"SYNTAX",
"InletSensorMeasurementsEntryStruct",
"MAX-ACCESS",
"not-accessible",
"STATUS",
"current",
"DESCRIPTION",
"\"An entry containing inlet sensor measurement objects.\"",
"INDEX",
"{",
"pduId",
",",
"inletId",
",",
"sensorType",
"}",
"::=",
"{",
"inletSensorMeasurementsTable",
"1",
"}"
],
"syntax_tree": [
[
"row",
"InletSensorMeasurementsEntryStruct"
],
null,
[
"MaxAccessPart",
"not-accessible"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"An entry containing inlet sensor measurement objects."
],
null,
null,
[
"INDEX",
[
[
0,
"pduId"
],
[
0,
"inletId"
],
[
0,
"sensorType"
]
]
],
null
]
}Vendor MIB copy from the LibreNMS archive.
Module: PDU2-MIB
See published definition above
{'SNMPv2-TC': ['TEXTUAL-CONVENTION', 'DisplayString', 'MacAddress', 'TruthValue', 'RowPointer'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'enterprises', 'Integer32', 'Unsigned32', 'IpAddress'], 'RFC1213-MIB': ['sysContact', 'sysName', 'sysLocation'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP', 'NOTIFICATION-GROUP'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress', 'InetPortNumber']}Related source files and packages:
Vendor MIB copy from the Observium Community archive.
Module: PDU2-MIB
{'SNMPv2-TC': ['TEXTUAL-CONVENTION', 'DisplayString', 'MacAddress', 'TruthValue', 'RowPointer'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'enterprises', 'Integer32', 'Unsigned32', 'IpAddress'], 'RFC1213-MIB': ['sysContact', 'sysName', 'sysLocation'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP', 'NOTIFICATION-GROUP'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress', 'InetPortNumber']}Related source files and packages:
Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.13742.6.5.2.3.1.2 | measurementsInletSensorIsAvailable | 0 | 0 | |
| 1.3.6.1.4.1.13742.6.5.2.3.1.3 | measurementsInletSensorState | 0 | 0 | |
| 1.3.6.1.4.1.13742.6.5.2.3.1.4 | measurementsInletSensorValue | 0 | 0 | |
| 1.3.6.1.4.1.13742.6.5.2.3.1.5 | measurementsInletSensorTimeStamp | 0 | 0 | |
| 1.3.6.1.4.1.13742.6.5.2.3.1.6 | measurementsInletSensorSignedValue | 0 | 0 | |
| 1.3.6.1.4.1.13742.6.5.2.3.1.7 | measurementsInletSensorMinMaxValid | 0 | 0 | |
| 1.3.6.1.4.1.13742.6.5.2.3.1.8 | measurementsInletSensorMinValue | 0 | 0 | |
| 1.3.6.1.4.1.13742.6.5.2.3.1.9 | measurementsInletSensorSignedMinValue | 0 | 0 | |
| 1.3.6.1.4.1.13742.6.5.2.3.1.10 | measurementsInletSensorMinTimeStamp | 0 | 0 | |
| 1.3.6.1.4.1.13742.6.5.2.3.1.11 | measurementsInletSensorMaxValue | 0 | 0 | |
| 1.3.6.1.4.1.13742.6.5.2.3.1.12 | measurementsInletSensorSignedMaxValue | 0 | 0 | |
| 1.3.6.1.4.1.13742.6.5.2.3.1.13 | measurementsInletSensorMaxTimeStamp | 0 | 0 | |
| 1.3.6.1.4.1.13742.6.5.2.3.1.14 | measurementsInletSensorMinMaxResetTimeStamp | 0 | 0 | |
| 1.3.6.1.4.1.13742.6.5.2.3.1.15 | measurementsInletSensorResetTimeStamp | 0 | 0 |