A unique value for the physical port, the LHX controlller is connected to. Its value ranges between 1 and the value of portCount.
Sources for this description
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
OID reference
1.3.6.1.4.1.13742.9.0.0.5
A unique value for the physical port, the LHX controlller is connected to. Its value ranges between 1 and the value of portCount.
Identification
{1 3 6 1 4 1 13742 9 0 0 5}
At least one MIB declaration places this object in a scalar group. A scalar instance uses the suffix .0.
A query example is omitted because the source variants do not establish compatible read access.
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
The displayed source records contain one distinct definition. Compare its source records.
portId OBJECT-TYPE
SYNTAX Integer32(1..256)
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"A unique value for the physical port, the LHX controlller
is connected to.
Its value ranges between 1 and the value of portCount."
::= { trapInformation 5 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
A unique value for the physical port, the LHX controlller is connected to. Its value ranges between 1 and the value of portCount.
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: current.
Names: portId
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"portId",
"OBJECT-TYPE",
"SYNTAX",
"Integer32",
"(",
"1",
".",
".",
"256",
")",
"MAX-ACCESS",
"accessible-for-notify",
"STATUS",
"current",
"DESCRIPTION",
"\"A unique value for the physical port, the LHX controlller is connected to. Its value ranges between 1 and the value of portCount.\"",
"::=",
"{",
"trapInformation",
"5",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"Integer32",
[
"integerSubType",
[
[
1,
256
]
]
]
],
null,
[
"MaxAccessPart",
"accessible-for-notify"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"A unique value for the physical port, the LHX controlller is connected to. Its value ranges between 1 and the value of portCount."
],
null,
null,
null,
null
]
}Vendor MIB copy from the Observium Community archive.
Module: LHX-MIB
See published definition above
{'SNMPv2-TC': ['TEXTUAL-CONVENTION', 'DisplayString', 'TruthValue'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'enterprises', 'Integer32', 'Unsigned32'], 'RFC1213-MIB': ['sysContact', 'sysName', 'sysLocation'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP', 'NOTIFICATION-GROUP'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress', 'InetPortNumber']}Related source files and packages:
Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.13742.9.0.0.1 | deviceName | 0 | 0 | |
| 1.3.6.1.4.1.13742.9.0.0.2 | deviceInetAddressType | 0 | 0 | |
| 1.3.6.1.4.1.13742.9.0.0.3 | deviceInetIPAddress | 0 | 0 | |
| 1.3.6.1.4.1.13742.9.0.0.4 | lhxErrorCode | 0 | 0 | |
| 1.3.6.1.4.1.13742.9.0.0.6 | probeId | 0 | 0 | |
| 1.3.6.1.4.1.13742.9.0.0.7 | fanId | 0 | 0 | |
| 1.3.6.1.4.1.13742.9.0.0.8 | powerSupplyId | 0 | 0 | |
| 1.3.6.1.4.1.13742.9.0.0.9 | oldSensorState | 0 | 0 | |
| 1.3.6.1.4.1.13742.9.0.0.10 | sensorTypeId | 0 | 0 | |
| 1.3.6.1.4.1.13742.9.0.0.11 | sensorId | 0 | 0 | |
| 1.3.6.1.4.1.13742.9.0.0.12 | oldOperationalState | 0 | 0 | |
| 1.3.6.1.4.1.13742.9.0.0.13 | agentInetPortNumber | 0 | 0 | |
| 1.3.6.1.4.1.13742.9.0.0.14 | deviceSerialNumber | 0 | 0 |