A collection of objects representing configuration data.
Sources for this description
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
OID reference
1.3.6.1.4.1.13742.9.3.2.1
A collection of objects representing configuration data.
Identification
{1 3 6 1 4 1 13742 9 3 2 1}
The displayed source records contain one distinct definition. Compare its source records.
configurationGroup
OBJECT-GROUP
OBJECTS {
portCount,
portId,
operationalState,
sensorCount,
sensorLabel,
sensorUnit,
sensorDecimalDigits,
sensorMaximum,
sensorMinimum,
sensorHysteresis,
sensorLowerCriticalThreshold,
sensorLowerWarningThreshold,
sensorUpperCriticalThreshold,
sensorUpperWarningThreshold,
sensorEnabledThresholds,
setpointVentilators,
setpointWaterValve,
defaultFanSpeed,
maximumCoolingState,
alertState,
sensorThresholdMaximum,
sensorThresholdMinimum,
model,
fwVersion,
sensorName
}
STATUS current
DESCRIPTION
"A collection of objects representing configuration data."
::= { groups 1 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
A collection of objects representing configuration data.
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: current.
Names: configurationGroup
{
"smi_kind": "OBJECT-GROUP",
"definition": [
"configurationGroup",
"OBJECT-GROUP",
"OBJECTS",
"{",
"portCount",
",",
"portId",
",",
"operationalState",
",",
"sensorCount",
",",
"sensorLabel",
",",
"sensorUnit",
",",
"sensorDecimalDigits",
",",
"sensorMaximum",
",",
"sensorMinimum",
",",
"sensorHysteresis",
",",
"sensorLowerCriticalThreshold",
",",
"sensorLowerWarningThreshold",
",",
"sensorUpperCriticalThreshold",
",",
"sensorUpperWarningThreshold",
",",
"sensorEnabledThresholds",
",",
"setpointVentilators",
",",
"setpointWaterValve",
",",
"defaultFanSpeed",
",",
"maximumCoolingState",
",",
"alertState",
",",
"sensorThresholdMaximum",
",",
"sensorThresholdMinimum",
",",
"model",
",",
"fwVersion",
",",
"sensorName",
"}",
"STATUS",
"current",
"DESCRIPTION",
"\"A collection of objects representing configuration data.\"",
"::=",
"{",
"groups",
"1",
"}"
],
"syntax_tree": [
[
"Objects",
[
"portCount",
"portId",
"operationalState",
"sensorCount",
"sensorLabel",
"sensorUnit",
"sensorDecimalDigits",
"sensorMaximum",
"sensorMinimum",
"sensorHysteresis",
"sensorLowerCriticalThreshold",
"sensorLowerWarningThreshold",
"sensorUpperCriticalThreshold",
"sensorUpperWarningThreshold",
"sensorEnabledThresholds",
"setpointVentilators",
"setpointWaterValve",
"defaultFanSpeed",
"maximumCoolingState",
"alertState",
"sensorThresholdMaximum",
"sensorThresholdMinimum",
"model",
"fwVersion",
"sensorName"
]
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"A collection of objects representing configuration data."
],
null
]
}Vendor MIB copy from the Observium Community archive.
Module: LHX-MIB
See published definition above
{'SNMPv2-TC': ['TEXTUAL-CONVENTION', 'DisplayString', 'TruthValue'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'enterprises', 'Integer32', 'Unsigned32'], 'RFC1213-MIB': ['sysContact', 'sysName', 'sysLocation'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP', 'NOTIFICATION-GROUP'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress', 'InetPortNumber']}Related source files and packages:
Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.13742.9.3.2.2 | measurementsGroup | 0 | 0 | |
| 1.3.6.1.4.1.13742.9.3.2.3 | trapInformationGroup | 0 | 0 | |
| 1.3.6.1.4.1.13742.9.3.2.4 | trapsGroup | 0 | 0 |