Status in source: mandatory.
Technical details
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"trapPerceivedSeverity",
"OBJECT-TYPE",
"SYNTAX",
"INTEGER",
"{",
"unknown",
"(",
"0",
")",
",",
"other",
"(",
"1",
")",
",",
"information",
"(",
"2",
")",
",",
"degradedWarning",
"(",
"3",
")",
",",
"minor",
"(",
"4",
")",
",",
"major",
"(",
"5",
")",
",",
"critical",
"(",
"6",
")",
",",
"fatalNonRecoverable",
"(",
"7",
")",
"}",
"MAX-ACCESS",
"read-only",
"STATUS",
"mandatory",
"DESCRIPTION",
"\"An enumerated value that describes the severity of the Alert Indication from the notifier's point of view: 1 - Other, by CIM convention, is used to indicate that the Severity's value can be found in the OtherSeverity property. 3 - Degraded/Warning should be used when its appropriate to let the user decide if action is needed. 4 - Minor should be used to indicate action is needed, but the situation is not serious at this time. 5 - Major should be used to indicate action is needed NOW. 6 - Critical should be used to indicate action is needed NOW and the scope is broad (perhaps an imminent outage to a critical resource will result). 7 - Fatal/NonRecoverable should be used to indicate an error occurred, but it's too late to take remedial action. 2 and 0 - Information and Unknown (respectively) follow common usage. Literally, the AlertIndication is purely informational or its severity is simply unknown. This would have values described in SMI-S 1.1 section 8.1.8.25 LibraryAlert Events/Indications for Library Devices, the PerceivedSeverity column. These values are a superset of the Info/Warning/Critical values in the T10 TapeAlert Specification v3 (w/SSC-3 Enhancements) , and an SNMP agent may choose to only specify those if that's all that's available. (This corresponds to the CIM_AlertIndication.PerceivedSeverity property.)\"",
"::=",
"{",
"trapGroup",
"6",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"INTEGER",
[
"enumSpec",
[
[
"unknown",
0
],
[
"other",
1
],
[
"information",
2
],
[
"degradedWarning",
3
],
[
"minor",
4
],
[
"major",
5
],
[
"critical",
6
],
[
"fatalNonRecoverable",
7
]
]
]
],
null,
[
"MaxAccessPart",
"read-only"
],
[
"Status",
"mandatory"
],
[
"DESCRIPTION",
"An enumerated value that describes the severity of the Alert Indication from the notifier's point of view: 1 - Other, by CIM convention, is used to indicate that the Severity's value can be found in the OtherSeverity property. 3 - Degraded/Warning should be used when its appropriate to let the user decide if action is needed. 4 - Minor should be used to indicate action is needed, but the situation is not serious at this time. 5 - Major should be used to indicate action is needed NOW. 6 - Critical should be used to indicate action is needed NOW and the scope is broad (perhaps an imminent outage to a critical resource will result). 7 - Fatal/NonRecoverable should be used to indicate an error occurred, but it's too late to take remedial action. 2 and 0 - Information and Unknown (respectively) follow common usage. Literally, the AlertIndication is purely informational or its severity is simply unknown. This would have values described in SMI-S 1.1 section 8.1.8.25 LibraryAlert Events/Indications for Library Devices, the PerceivedSeverity column. These values are a superset of the Info/Warning/Critical values in the T10 TapeAlert Specification v3 (w/SSC-3 Enhancements) , and an SNMP agent may choose to only specify those if that's all that's available. (This corresponds to the CIM_AlertIndication.PerceivedSeverity property.)"
],
null,
null,
null,
null
]
}